{"@context":{"@vocab":"https://cir.nii.ac.jp/schema/1.0/","rdfs":"http://www.w3.org/2000/01/rdf-schema#","dc":"http://purl.org/dc/elements/1.1/","dcterms":"http://purl.org/dc/terms/","foaf":"http://xmlns.com/foaf/0.1/","prism":"http://prismstandard.org/namespaces/basic/2.0/","cinii":"http://ci.nii.ac.jp/ns/1.0/","datacite":"https://schema.datacite.org/meta/kernel-4/","ndl":"http://ndl.go.jp/dcndl/terms/","jpcoar":"https://github.com/JPCOAR/schema/blob/master/2.0/"},"@id":"https://cir.nii.ac.jp/crid/1040000781994121856.json","@type":"Project","projectIdentifier":[{"@type":"KAKEN","@value":"18H03807"},{"@type":"JGN","@value":"JP18H03807"},{"@type":"URI","@value":"https://kaken.nii.ac.jp/grant/KAKENHI-PROJECT-18H03807/"}],"jpcoar:awardTitle":[{"@language":"ja","@value":"健康影響を可視化するin silico人体モデルの開発と環境設計への展開"},{"@language":"en","@value":"Development of in silico human model and its application to indoor environmental design"}],"field":[{"keyword":[{"language":"ja","textList":["中区分23:建築学およびその関連分野"]},{"language":"en","textList":["Medium-sized Section 23:Architecture, building engineering, and related fields"]}]}],"dc:language":"ja","description":[{"type":"outline_of_research_achievement","notation":[{"@language":"ja","@value":"本研究は，汚染空気暴露に伴う健康影響を可視化するin silico人体モデルの開発に取り組んだ．特にガス状ならびにエアロゾル状の各種空気汚染物質を対象として，呼吸に伴う経気道暴露，沈着や接触に伴う経皮暴露による人体影響を定量的に予測・評価する数理モデルを開発した上で，その数値解析用の人体プラットフォームを作成した．具体的に，経気道暴露・経皮暴露経路と人体暴露メカニズムを数理的に記述する生理的薬物動態モデルを人体モデルに統合した新たなin silico人体モデルを作成し，熱流体解析技術(CFD)と統合することで，人体－環境系の総合的な数値解析手法を確立した．"},{"@language":"en","@value":"We developed an in silico human model to visualize health risk associated with exposure to contaminated indoor air. In particular, we developed numerical models that can predict inhalation exposure in respiratory tract and dermal exposure by deposition of gas-phase contaminant. Specifically, (1)we newly developed physiologically based pharmacokinetic/toxicokinetic models that reproduce inhalation exposure and dermal exposure, and (2)these models were integrated into the in silico human model that precisely reproduced body surface and respiratory tract geometry. (3) We also established a comprehensive analysis method for human-environment systems that integrates in silico human model and computational fluid dynamics (CFD) technique. Finally, (4)we conducted demonstrative analyses for e-cigarette smoking in an indoor environment and showed quantitatively the potential effects of e-cigarette smoking on local tissue dosimetry and the deterioration of indoor air quality."}]},{"type":"significance_of_research_achievement","notation":[{"@language":"ja","@value":"建築空間における健康影響評価のための研究手法である被験者実験は，非常に有用なデータ取得が可能である一方，その実施には倫理的制約がある．被験者実験を補完・代替する夕食な手法がコンピュータ上に人体生理を再現したin silico人体モデルによる数値実験法である．本研究では汎用的な室内環境設計に適用される既存の環境解析技術に統合可能で，経気道・経皮曝露を定量的に評価可能な全く新しいコンセプトのin silico人体モデルを開発した．この成果により，不完全混合場を対象とした局所領域環境制御を目的とする自由度の高いパラメトリック解析が可能となる．"}]}],"researcher":[{"@id":"https://cir.nii.ac.jp/crid/1420845751159436928","@type":"Researcher","personIdentifier":[{"@type":"KAKEN_RESEARCHERS","@value":"20329220"},{"@type":"NRID","@value":"1000020329220"},{"@type":"ORCID","@value":"0000-0002-7715-7896"},{"@type":"NRID","@value":"9000304601519"},{"@type":"NRID","@value":"9000400813112"},{"@type":"NRID","@value":"9000279888306"},{"@type":"NRID","@value":"9000244914371"},{"@type":"NRID","@value":"9000242943133"},{"@type":"NRID","@value":"9000401268415"},{"@type":"NRID","@value":"9000413712904"},{"@type":"NRID","@value":"9000018509485"},{"@type":"NRID","@value":"9000242920470"},{"@type":"NRID","@value":"9000370749646"},{"@type":"NRID","@value":"9000414845267"},{"@type":"NRID","@value":"9000401160825"},{"@type":"NRID","@value":"9000016984428"},{"@type":"NRID","@value":"9000401125874"},{"@type":"NRID","@value":"9000242952141"},{"@type":"NRID","@value":"9000242952144"},{"@type":"NRID","@value":"9000018330645"},{"@type":"NRID","@value":"9000304601478"},{"@type":"NRID","@value":"9000241698973"},{"@type":"NRID","@value":"9000370753099"},{"@type":"NRID","@value":"9000370749379"},{"@type":"NRID","@value":"9000345198989"},{"@type":"NRID","@value":"9000401401451"},{"@type":"NRID","@value":"9000414226749"},{"@type":"NRID","@value":"9000404824901"},{"@type":"NRID","@value":"9000401125966"},{"@type":"NRID","@value":"9000401124849"},{"@type":"NRID","@value":"9000242920489"},{"@type":"NRID","@value":"9000401257877"},{"@type":"NRID","@value":"9000401160812"},{"@type":"NRID","@value":"9000253511683"},{"@type":"NRID","@value":"9000411114659"},{"@type":"NRID","@value":"9000404842159"},{"@type":"NRID","@value":"9000400813101"},{"@type":"NRID","@value":"9000401124752"},{"@type":"NRID","@value":"9000021686805"},{"@type":"NRID","@value":"9000242951082"},{"@type":"NRID","@value":"9000401268435"},{"@type":"NRID","@value":"9000414845293"},{"@type":"NRID","@value":"9000019108261"},{"@type":"NRID","@value":"9000400454336"},{"@type":"NRID","@value":"9000401124756"},{"@type":"NRID","@value":"9000400827446"},{"@type":"NRID","@value":"9000401268418"},{"@type":"NRID","@value":"9000380975456"},{"@type":"NRID","@value":"9000414845271"},{"@type":"NRID","@value":"9000401381799"},{"@type":"NRID","@value":"9000411228238"},{"@type":"NRID","@value":"9000403168140"},{"@type":"NRID","@value":"9000243835687"},{"@type":"NRID","@value":"9000400454386"},{"@type":"NRID","@value":"9000400824807"},{"@type":"NRID","@value":"9000244930497"},{"@type":"NRID","@value":"9000242944366"},{"@type":"NRID","@value":"9000403840378"},{"@type":"NRID","@value":"9000400815943"},{"@type":"NRID","@value":"9000400816319"},{"@type":"NRID","@value":"9000242524863"},{"@type":"NRID","@value":"9000242942992"},{"@type":"NRID","@value":"9000414845318"},{"@type":"NRID","@value":"9000400815896"},{"@type":"NRID","@value":"9000017548279"},{"@type":"NRID","@value":"9000400827398"},{"@type":"NRID","@value":"9000244919148"},{"@type":"NRID","@value":"9000348792648"},{"@type":"NRID","@value":"9000242952138"},{"@type":"NRID","@value":"9000345257726"},{"@type":"NRID","@value":"9000401219724"},{"@type":"NRID","@value":"9000401162780"},{"@type":"NRID","@value":"9000021672904"},{"@type":"NRID","@value":"9000400829631"},{"@type":"NRID","@value":"9000400816853"},{"@type":"NRID","@value":"9000392843495"},{"@type":"NRID","@value":"9000401257879"},{"@type":"NRID","@value":"9000401160988"},{"@type":"NRID","@value":"9000414845281"},{"@type":"NRID","@value":"9000404824905"},{"@type":"NRID","@value":"9000399332749"},{"@type":"NRID","@value":"9000406220511"},{"@type":"NRID","@value":"9000401125308"},{"@type":"NRID","@value":"9000400816847"},{"@type":"NRID","@value":"9000242525079"},{"@type":"NRID","@value":"9000401251580"},{"@type":"NRID","@value":"9000401257887"},{"@type":"NRID","@value":"9000401160820"},{"@type":"NRID","@value":"9000414845323"},{"@type":"NRID","@value":"9000305631747"},{"@type":"NRID","@value":"9000401125958"},{"@type":"NRID","@value":"9000400824662"},{"@type":"NRID","@value":"9000400815946"},{"@type":"NRID","@value":"9000401124853"},{"@type":"NRID","@value":"9000400444474"},{"@type":"NRID","@value":"9000242942999"},{"@type":"NRID","@value":"9000415325090"},{"@type":"NRID","@value":"9000016411095"},{"@type":"NRID","@value":"9000401125304"},{"@type":"NRID","@value":"9000400829633"},{"@type":"NRID","@value":"9000400813231"},{"@type":"NRID","@value":"9000400813225"},{"@type":"NRID","@value":"9000401124857"},{"@type":"NRID","@value":"9000401221637"},{"@type":"NRID","@value":"9000410322419"},{"@type":"NRID","@value":"9000398776986"},{"@type":"NRID","@value":"9000401125301"},{"@type":"NRID","@value":"9000400829581"},{"@type":"NRID","@value":"9000400824660"},{"@type":"NRID","@value":"9000400815692"},{"@type":"NRID","@value":"9000401124860"},{"@type":"NRID","@value":"9000392843493"},{"@type":"NRID","@value":"9000242943135"},{"@type":"NRID","@value":"9000304601481"},{"@type":"NRID","@value":"9000243835682"},{"@type":"NRID","@value":"9000401125963"},{"@type":"NRID","@value":"9000401125968"},{"@type":"NRID","@value":"9000006848952"},{"@type":"NRID","@value":"9000400454329"},{"@type":"NRID","@value":"9000400813228"},{"@type":"NRID","@value":"9000400813107"},{"@type":"NRID","@value":"9000401268432"},{"@type":"NRID","@value":"9000369744996"},{"@type":"NRID","@value":"9000401338938"},{"@type":"NRID","@value":"9000401162774"},{"@type":"NRID","@value":"9000257866481"},{"@type":"NRID","@value":"9000315155216"},{"@type":"NRID","@value":"9000401125311"},{"@type":"NRID","@value":"9000400824654"},{"@type":"NRID","@value":"9000400444533"},{"@type":"NRID","@value":"9000401158677"},{"@type":"NRID","@value":"9000414845298"},{"@type":"RESEARCHMAP","@value":"https://researchmap.jp/kazuhide.ito"}],"foaf:name":[{"@language":"ja","@value":"伊藤 一秀"},{"@language":"en","@value":"Ito Kazuhide"}],"jpcoar:affiliationName":[{"@language":"ja","@value":"九州大学"}],"role":"principal_investigator"}],"since":"2018-04-01","until":"2022-03-31","institution":[{"institutionIdentifier":[{"@type":"NII","@value":"0017102"}],"notation":[{"@language":"ja","@value":"九州大学"},{"@language":"en","@value":"Kyushu University"}]}],"fundingProgram":[{"jpcoar:funderName":[{"@language":"ja","@value":"科学研究費助成事業"},{"@language":"en","@value":"Grants-in-Aid for Scientific Research"}]}],"url":[{"@id":"https://kaken.nii.ac.jp/grant/KAKENHI-PROJECT-18H03807/","notation":[{"@value":"KAKEN"}]}],"createdAt":"2018-04-23","modifiedAt":"2025-11-19","foaf:topic":[{"@id":"https://cir.nii.ac.jp/all?q=in%20silico%E4%BA%BA%E4%BD%93%E3%83%A2%E3%83%87%E3%83%AB","dc:title":"in silico人体モデル"},{"@id":"https://cir.nii.ac.jp/all?q=%E8%A8%88%E7%AE%97%E6%B5%81%E4%BD%93%E5%8A%9B%E5%AD%A6","dc:title":"計算流体力学"},{"@id":"https://cir.nii.ac.jp/all?q=%E7%B5%8C%E6%B0%97%E9%81%93%E6%9B%9D%E9%9C%B2","dc:title":"経気道曝露"},{"@id":"https://cir.nii.ac.jp/all?q=%E7%B5%8C%E7%9A%AE%E6%9B%9D%E9%9C%B2","dc:title":"経皮曝露"},{"@id":"https://cir.nii.ac.jp/all?q=%E5%AE%A4%E5%86%85%E7%92%B0%E5%A2%83%E8%A7%A3%E6%9E%90","dc:title":"室内環境解析"},{"@id":"https://cir.nii.ac.jp/all?q=in%20silico%20human%20model","dc:title":"in silico human model"},{"@id":"https://cir.nii.ac.jp/all?q=CFD","dc:title":"CFD"},{"@id":"https://cir.nii.ac.jp/all?q=%E5%AE%A4%E5%86%85%E7%A9%BA%E6%B0%97%E8%B3%AA","dc:title":"室内空気質"},{"@id":"https://cir.nii.ac.jp/all?q=%E7%B5%8C%E6%B0%97%E9%81%93%E6%9A%B4%E9%9C%B2","dc:title":"経気道暴露"},{"@id":"https://cir.nii.ac.jp/all?q=%E7%B5%8C%E7%9A%AE%E6%9A%B4%E9%9C%B2","dc:title":"経皮暴露"},{"@id":"https://cir.nii.ac.jp/all?q=in%20sikico%20human%20model","dc:title":"in sikico human model"}],"product":[{"@id":"https://cir.nii.ac.jp/crid/1360861286492806016","@type":"Article","resourceType":"学術雑誌論文(journal article)","productIdentifier":[{"@type":"DOI","@value":"10.4209/aaqr.210338"},{"@type":"URI","@value":"https://aaqr.org/articles/aaqr-21-11-covid2-0338.pdf"},{"@type":"HANDLE","@value":"2123/29099"}],"notation":[{"@value":"Exhaled Jet and Viral-Laden Aerosol Transport from Nasal Sneezing"}]},{"@id":"https://cir.nii.ac.jp/crid/1360861289637940736","@type":"Article","resourceType":"学術雑誌論文(journal article)","productIdentifier":[{"@type":"DOI","@value":"10.3390/su14073896"},{"@type":"URI","@value":"https://www.mdpi.com/2071-1050/14/7/3896/pdf"}],"notation":[{"@value":"SARS-CoV-2 Dynamics in the Mucus Layer of the Human Upper Respiratory Tract Based on Host–Cell Dynamics"}]},{"@id":"https://cir.nii.ac.jp/crid/1360576118707303424","@type":"Article","resourceType":"学術雑誌論文(journal article)","productIdentifier":[{"@type":"DOI","@value":"10.1016/j.buildenv.2021.108735"},{"@type":"URI","@value":"https://api.elsevier.com/content/article/PII:S0360132321011240?httpAccept=text/xml"},{"@type":"URI","@value":"https://api.elsevier.com/content/article/PII:S0360132321011240?httpAccept=text/plain"}],"notation":[{"@value":"CO2 emission rates from sedentary subjects under controlled laboratory conditions"}]},{"@id":"https://cir.nii.ac.jp/crid/1360857593684009216","@type":"Article","resourceType":"学術雑誌論文(journal article)","productIdentifier":[{"@type":"DOI","@value":"10.1016/j.buildenv.2021.108666"},{"@type":"URI","@value":"https://api.elsevier.com/content/article/PII:S0360132321010568?httpAccept=text/xml"},{"@type":"URI","@value":"https://api.elsevier.com/content/article/PII:S0360132321010568?httpAccept=text/plain"},{"@type":"HANDLE","@value":"1854/LU-8735993"}],"notation":[{"@value":"The effects of ventilation and temperature on sleep quality and next-day work performance: pilot measurements in a climate chamber"}]},{"@id":"https://cir.nii.ac.jp/crid/1360572592070389248","@type":"Article","resourceType":"学術雑誌論文(journal article)","productIdentifier":[{"@type":"DOI","@value":"10.1002/2475-8876.12261"},{"@type":"URI","@value":"https://onlinelibrary.wiley.com/doi/pdf/10.1002/2475-8876.12261"},{"@type":"URI","@value":"https://onlinelibrary.wiley.com/doi/full-xml/10.1002/2475-8876.12261"},{"@type":"NAID","@value":"210000188875"}],"notation":[{"@value":"Dispersion characteristics of oral microbial communities in a built environment"}]},{"@id":"https://cir.nii.ac.jp/crid/1360013168754942848","@type":"Article","resourceType":"学術雑誌論文(journal article)","productIdentifier":[{"@type":"DOI","@value":"10.1111/ina.13003"},{"@type":"URI","@value":"https://onlinelibrary.wiley.com/doi/pdf/10.1111/ina.13003"},{"@type":"URI","@value":"https://onlinelibrary.wiley.com/doi/full-xml/10.1111/ina.13003"},{"@type":"PMID","@value":"35225397"}],"notation":[{"@value":"Breathing zone and exhaled air re‐inhalation rate under transient conditions assessed with a computer‐simulated person"}]},{"@id":"https://cir.nii.ac.jp/crid/1360013168755134336","@type":"Article","resourceType":"学術雑誌論文(journal article)","productIdentifier":[{"@type":"DOI","@value":"10.1177/1420326x211066538"},{"@type":"URI","@value":"https://journals.sagepub.com/doi/pdf/10.1177/1420326X211066538"},{"@type":"URI","@value":"https://journals.sagepub.com/doi/full-xml/10.1177/1420326X211066538"}],"notation":[{"@value":"Pollutant capture efficiencies in and around the opening surface of a fume hood under realistic conditions"}]},{"@id":"https://cir.nii.ac.jp/crid/1360294643731650560","@type":"Article","resourceType":"学術雑誌論文(journal article)","productIdentifier":[{"@type":"DOI","@value":"10.1111/ina.12911"},{"@type":"URI","@value":"https://onlinelibrary.wiley.com/doi/pdf/10.1111/ina.12911"},{"@type":"URI","@value":"https://onlinelibrary.wiley.com/doi/full-xml/10.1111/ina.12911"},{"@type":"PMID","@value":"34337798"}],"notation":[{"@value":"Emission rate of carbon dioxide while sleeping"}]},{"@id":"https://cir.nii.ac.jp/crid/1360576118707345664","@type":"Article","resourceType":"学術雑誌論文(journal article)","productIdentifier":[{"@type":"DOI","@value":"10.1016/j.cis.2021.102468"},{"@type":"URI","@value":"https://api.elsevier.com/content/article/PII:S0001868621001093?httpAccept=text/xml"},{"@type":"URI","@value":"https://api.elsevier.com/content/article/PII:S0001868621001093?httpAccept=text/plain"},{"@type":"PMID","@value":"34198212"}],"notation":[{"@value":"A critical overview of adsorption kinetics for cooling and refrigeration systems"}]},{"@id":"https://cir.nii.ac.jp/crid/1360857593685263744","@type":"Article","resourceType":"学術雑誌論文(journal article)","productIdentifier":[{"@type":"DOI","@value":"10.1177/1420326x211059449"},{"@type":"URI","@value":"https://journals.sagepub.com/doi/pdf/10.1177/1420326X211059449"},{"@type":"URI","@value":"https://journals.sagepub.com/doi/full-xml/10.1177/1420326X211059449"}],"notation":[{"@value":"Hygro-thermo-chemical transfer analysis of clothing microclimate using three-dimensional digital clothing model and computer-simulated person"}]},{"@id":"https://cir.nii.ac.jp/crid/1361694366698234112","@type":"Article","resourceType":"学術雑誌論文(journal article)","productIdentifier":[{"@type":"DOI","@value":"10.1016/j.envpol.2019.06.056"},{"@type":"URI","@value":"https://api.elsevier.com/content/article/PII:S0269749119308048?httpAccept=text/xml"},{"@type":"URI","@value":"https://api.elsevier.com/content/article/PII:S0269749119308048?httpAccept=text/plain"},{"@type":"PMID","@value":"31254896"}],"notation":[{"@value":"Can the inhalation exposure of a specific worker in a cross-ventilated factory be evaluated by time- and spatial-averaged contaminant concentration?"}]},{"@id":"https://cir.nii.ac.jp/crid/1361694366562087168","@type":"Article","resourceType":"学術雑誌論文(journal article)","productIdentifier":[{"@type":"DOI","@value":"10.1016/j.buildenv.2019.106487"},{"@type":"URI","@value":"https://api.elsevier.com/content/article/PII:S0360132319306997?httpAccept=text/xml"},{"@type":"URI","@value":"https://api.elsevier.com/content/article/PII:S0360132319306997?httpAccept=text/plain"}],"notation":[{"@value":"Influence of chemical reactions and turbulent diffusion on the formation of local pollutant concentration distributions"}]},{"@id":"https://cir.nii.ac.jp/crid/1360285709146812672","@type":"Article","resourceType":"学術雑誌論文(journal article)","productIdentifier":[{"@type":"DOI","@value":"10.1080/08958378.2018.1545810"},{"@type":"URI","@value":"https://www.tandfonline.com/doi/pdf/10.1080/08958378.2018.1545810"},{"@type":"PMID","@value":"30618352"}],"notation":[{"@value":"Particle and inhalation exposure in human and monkey computational airway models"}]},{"@id":"https://cir.nii.ac.jp/crid/1360290617417032064","@type":"Article","resourceType":"学術雑誌論文(journal article)","productIdentifier":[{"@type":"DOI","@value":"10.1002/cnm.3414"},{"@type":"URI","@value":"https://onlinelibrary.wiley.com/doi/pdf/10.1002/cnm.3414"},{"@type":"URI","@value":"https://onlinelibrary.wiley.com/doi/full-xml/10.1002/cnm.3414"},{"@type":"URI","@value":"https://onlinelibrary.wiley.com/doi/am-pdf/10.1002/cnm.3414"},{"@type":"PMID","@value":"33205913"}],"notation":[{"@value":"Numerical analysis of nanoparticle transport and deposition in a cynomolgus monkey nasal passage"}]},{"@id":"https://cir.nii.ac.jp/crid/1360290617415713280","@type":"Article","resourceType":"学術雑誌論文(journal article)","productIdentifier":[{"@type":"DOI","@value":"10.1016/j.enbenv.2020.05.005"},{"@type":"URI","@value":"https://api.elsevier.com/content/article/PII:S2666123320300428?httpAccept=text/xml"},{"@type":"URI","@value":"https://api.elsevier.com/content/article/PII:S2666123320300428?httpAccept=text/plain"}],"notation":[{"@value":"Experimental study of oil mist characteristics generated from minimum quantity lubrication and flood cooling"}]},{"@id":"https://cir.nii.ac.jp/crid/1360013168753939072","@type":"Article","resourceType":"学術雑誌論文(journal article)","productIdentifier":[{"@type":"DOI","@value":"10.1016/j.compbiomed.2021.104398"},{"@type":"URI","@value":"https://api.elsevier.com/content/article/PII:S001048252100192X?httpAccept=text/xml"},{"@type":"URI","@value":"https://api.elsevier.com/content/article/PII:S001048252100192X?httpAccept=text/plain"},{"@type":"PMID","@value":"33905990"}],"notation":[{"@value":"Computational fluid dynamics comparison of impaired breathing function in French bulldogs with nostril stenosis and an examination of the efficacy of rhinoplasty"}]},{"@id":"https://cir.nii.ac.jp/crid/1361412896646181632","@type":"Article","resourceType":"学術雑誌論文(journal article)","productIdentifier":[{"@type":"DOI","@value":"10.1177/1420326x19894128"},{"@type":"URI","@value":"https://journals.sagepub.com/doi/pdf/10.1177/1420326X19894128"},{"@type":"URI","@value":"https://journals.sagepub.com/doi/full-xml/10.1177/1420326X19894128"}],"notation":[{"@value":"Comparative numerical simulation of inhaled particle dispersion in upper human airway to analyse intersubject differences"}]},{"@id":"https://cir.nii.ac.jp/crid/1361131417165570816","@type":"Article","resourceType":"学術雑誌論文(journal article)","productIdentifier":[{"@type":"DOI","@value":"10.1016/j.resp.2019.103304"},{"@type":"URI","@value":"https://api.elsevier.com/content/article/PII:S1569904819302186?httpAccept=text/xml"},{"@type":"URI","@value":"https://api.elsevier.com/content/article/PII:S1569904819302186?httpAccept=text/plain"},{"@type":"PMID","@value":"31546025"}],"notation":[{"@value":"CFD analysis of the flow structure in a monkey upper airway validated by PIV experiments"}]},{"@id":"https://cir.nii.ac.jp/crid/1360286991634158592","@type":"Article","resourceType":"学術雑誌論文(journal article)","productIdentifier":[{"@type":"DOI","@value":"10.1016/j.atmosenv.2019.116979"},{"@type":"URI","@value":"https://api.elsevier.com/content/article/PII:S1352231019306181?httpAccept=text/xml"},{"@type":"URI","@value":"https://api.elsevier.com/content/article/PII:S1352231019306181?httpAccept=text/plain"}],"notation":[{"@value":"Distribution of transient formaldehyde concentration in confined small glass desiccators and its impact on emission rate measurement"}]},{"@id":"https://cir.nii.ac.jp/crid/1361131420440773632","@type":"Article","resourceType":"学術雑誌論文(journal article)","productIdentifier":[{"@type":"DOI","@value":"10.1111/ina.12666"},{"@type":"URI","@value":"https://api.wiley.com/onlinelibrary/tdm/v1/articles/10.1111%2Fina.12666"},{"@type":"URI","@value":"https://onlinelibrary.wiley.com/doi/pdf/10.1111/ina.12666"},{"@type":"URI","@value":"https://onlinelibrary.wiley.com/doi/full-xml/10.1111/ina.12666"},{"@type":"PMID","@value":"32159877"}],"notation":[{"@value":"A numerical investigation of the potential effects of e‐cigarette smoking on local tissue dosimetry and the deterioration of indoor air quality"}]},{"@id":"https://cir.nii.ac.jp/crid/1360848657125663872","@type":"Article","resourceType":"学術雑誌論文(journal article)","productIdentifier":[{"@type":"DOI","@value":"10.1016/j.ijheatmasstransfer.2018.01.107"},{"@type":"URI","@value":"https://api.elsevier.com/content/article/PII:S0017931017349724?httpAccept=text/xml"},{"@type":"URI","@value":"https://api.elsevier.com/content/article/PII:S0017931017349724?httpAccept=text/plain"}],"notation":[{"@value":"Theoretical framework to evaluate minimum desorption temperature for IUPAC classified adsorption isotherms"}]},{"@id":"https://cir.nii.ac.jp/crid/1360576118708593920","@type":"Article","resourceType":"学術雑誌論文(journal article)","productIdentifier":[{"@type":"DOI","@value":"10.1371/journal.pcbi.1009004"},{"@type":"URI","@value":"https://dx.plos.org/10.1371/journal.pcbi.1009004"},{"@type":"PMID","@value":"33983924"}],"notation":[{"@value":"Secondary indoor air pollution and passive smoking associated with cannabis smoking using electric cigarette device–demonstrative in silico study"}]},{"@id":"https://cir.nii.ac.jp/crid/1390845713036539520","@type":"Article","resourceType":"学術雑誌論文(journal article)","productIdentifier":[{"@type":"DOI","@value":"10.3130/aije.83.1005"},{"@type":"NDL_BIB_ID","@value":"029399342"},{"@type":"NDL_CALL_NUMBER","@value":"Z74-D484"},{"@type":"URI","@value":"http://id.ndl.go.jp/bib/029399342"},{"@type":"URI","@value":"https://ndlsearch.ndl.go.jp/books/R000000004-I029399342"},{"@type":"URI","@value":"https://www.jstage.jst.go.jp/article/aije/83/754/83_1005/_pdf"},{"@type":"NAID","@value":"130007599064"}],"notation":[{"@language":"ja","@value":"呼吸器系統合型数値人体モデルを用いた電子煙草(e-Cigarette)使用に伴う1次・2次暴露リスクの定量評価"},{"@language":"en","@value":"QUANTITATIVE RISK ASSESSMENT OF THE FIRST-HAND / SECOND-HAND EXPOSURE OCCURRED BY VAPING USING COMPUTER SIMULATED PERSON INTEGRATED WITH VIRTUAL AIRWAY"},{"@language":"ja-Kana","@value":"コキュウキケイ トウゴウガタ スウチ ジンタイ モデル オ モチイタ デンシ タバコ(e-Cigarette)シヨウ ニ トモナウ 1ジ ・ 2ジ バクロ リスク ノ テイリョウ ヒョウカ"}]},{"@id":"https://cir.nii.ac.jp/crid/1360004237623305984","@type":"Article","resourceType":"学術雑誌論文(journal article)","productIdentifier":[{"@type":"DOI","@value":"10.1371/journal.pone.0195925"},{"@type":"URI","@value":"http://dx.plos.org/10.1371/journal.pone.0195925"},{"@type":"PMID","@value":"29672571"}],"notation":[{"@value":"Measurement of heating coil temperature for e-cigarettes with a “top-coil” clearomizer"}]},{"@id":"https://cir.nii.ac.jp/crid/1360849944142710784","@type":"Article","resourceType":"学術雑誌論文(journal article)","productIdentifier":[{"@type":"DOI","@value":"10.1080/17512549.2019.1607776"},{"@type":"URI","@value":"https://www.tandfonline.com/doi/pdf/10.1080/17512549.2019.1607776"}],"notation":[{"@value":"Does detailed hygrothermal transport analysis in respiratory tract affect skin surface temperature distributions by thermoregulation model?"}]},{"@id":"https://cir.nii.ac.jp/crid/1361975841063049216","@type":"Article","resourceType":"学術雑誌論文(journal article)","productIdentifier":[{"@type":"DOI","@value":"10.1007/s42757-019-0016-z"},{"@type":"URI","@value":"https://link.springer.com/content/pdf/10.1007/s42757-019-0016-z.pdf"},{"@type":"URI","@value":"https://link.springer.com/article/10.1007/s42757-019-0016-z/fulltext.html"},{"@type":"PMID","@value":"32289121"}],"notation":[{"@value":"Numerical investigation of indoor particulate contaminant transport using the Eulerian-Eulerian and Eulerian-Lagrangian two-phase flow models"}]},{"@id":"https://cir.nii.ac.jp/crid/1360290617418352768","@type":"Article","resourceType":"学術雑誌論文(journal article)","productIdentifier":[{"@type":"DOI","@value":"10.1111/ina.12803"},{"@type":"URI","@value":"https://onlinelibrary.wiley.com/doi/pdf/10.1111/ina.12803"},{"@type":"URI","@value":"https://onlinelibrary.wiley.com/doi/full-xml/10.1111/ina.12803"},{"@type":"PMID","@value":"33605467"}],"notation":[{"@value":"Returning characteristics of pollutants for a local domain in the presence of returning and recirculating airflow in indoor environments"}]},{"@id":"https://cir.nii.ac.jp/crid/1360568466179496064","@type":"Article","resourceType":"学術雑誌論文(journal article)","productIdentifier":[{"@type":"DOI","@value":"10.1007/s42757-019-0014-1"},{"@type":"URI","@value":"https://link.springer.com/content/pdf/10.1007/s42757-019-0014-1.pdf"},{"@type":"URI","@value":"https://link.springer.com/article/10.1007/s42757-019-0014-1/fulltext.html"}],"notation":[{"@value":"Computational fluid dynamics investigation of particle intake for nasal breathing by a moving body"}]},{"@id":"https://cir.nii.ac.jp/crid/1360572092392626432","@type":"Article","resourceType":"学術雑誌論文(journal article)","productIdentifier":[{"@type":"DOI","@value":"10.1016/j.resp.2020.103587"},{"@type":"URI","@value":"https://api.elsevier.com/content/article/PII:S1569904820302469?httpAccept=text/xml"},{"@type":"URI","@value":"https://api.elsevier.com/content/article/PII:S1569904820302469?httpAccept=text/plain"},{"@type":"PMID","@value":"33212243"}],"notation":[{"@value":"Inhalation airflow and ventilation efficiency in subject-specific human upper airways"}]},{"@id":"https://cir.nii.ac.jp/crid/1360009142440675584","@type":"Article","resourceType":"学術雑誌論文(journal article)","productIdentifier":[{"@type":"DOI","@value":"10.1016/j.enbenv.2020.04.011"},{"@type":"URI","@value":"https://api.elsevier.com/content/article/PII:S2666123320300374?httpAccept=text/xml"},{"@type":"URI","@value":"https://api.elsevier.com/content/article/PII:S2666123320300374?httpAccept=text/plain"}],"notation":[{"@value":"Investigation of transient and heterogeneous micro-climate around a human body in an enclosed personalized work environment"}]},{"@id":"https://cir.nii.ac.jp/crid/1360290617418115456","@type":"Article","resourceType":"学術雑誌論文(journal article)","productIdentifier":[{"@type":"DOI","@value":"10.1080/08958378.2020.1800148"},{"@type":"URI","@value":"https://www.tandfonline.com/doi/pdf/10.1080/08958378.2020.1800148"},{"@type":"PMID","@value":"32729366"}],"notation":[{"@value":"Numerical modeling of nanoparticle deposition in realistic monkey airway and human airway models: a comparative study"}]},{"@id":"https://cir.nii.ac.jp/crid/1360576118708550144","@type":"Article","resourceType":"学術雑誌論文(journal article)","productIdentifier":[{"@type":"DOI","@value":"10.1177/1420326x211026360"},{"@type":"URI","@value":"https://journals.sagepub.com/doi/pdf/10.1177/1420326X211026360"},{"@type":"URI","@value":"https://journals.sagepub.com/doi/full-xml/10.1177/1420326X211026360"}],"notation":[{"@value":"Hybrid emergency ventilation system for controlling inhaled contaminant dose in the case of chemical leakage"}]},{"@id":"https://cir.nii.ac.jp/crid/1360004232497666688","@type":"Article","resourceType":"学術雑誌論文(journal article)","productIdentifier":[{"@type":"DOI","@value":"10.1016/j.scs.2018.04.023"},{"@type":"URI","@value":"https://api.elsevier.com/content/article/PII:S2210670718301975?httpAccept=text/xml"},{"@type":"URI","@value":"https://api.elsevier.com/content/article/PII:S2210670718301975?httpAccept=text/plain"}],"notation":[{"@value":"Assessment of transient inhalation exposure using in silico human model integrated with PBPK-CFD hybrid analysis"}]},{"@id":"https://cir.nii.ac.jp/crid/1360013168754936704","@type":"Article","resourceType":"学術雑誌論文(journal article)","productIdentifier":[{"@type":"DOI","@value":"10.1111/ina.12852"},{"@type":"URI","@value":"https://onlinelibrary.wiley.com/doi/pdf/10.1111/ina.12852"},{"@type":"URI","@value":"https://onlinelibrary.wiley.com/doi/full-xml/10.1111/ina.12852"}],"notation":[{"@value":"The effects of warmth and CO\n                    <sub>2</sub>\n                    concentration, with and without bioeffluents, on the emission of CO\n                    <sub>2</sub>\n                    by occupants and physiological responses"}]},{"@id":"https://cir.nii.ac.jp/crid/1360009142438996992","@type":"Article","resourceType":"学術雑誌論文(journal article)","productIdentifier":[{"@type":"DOI","@value":"10.1016/j.enbenv.2020.04.007"},{"@type":"URI","@value":"https://api.elsevier.com/content/article/PII:S2666123320300337?httpAccept=text/xml"},{"@type":"URI","@value":"https://api.elsevier.com/content/article/PII:S2666123320300337?httpAccept=text/plain"}],"notation":[{"@value":"Decreasing inhaled contaminant dose of a factory worker through a hybrid Emergency Ventilation System: Performance evaluation in worst-case scenario"}]},{"@id":"https://cir.nii.ac.jp/crid/1361975846599601152","@type":"Article","resourceType":"学術雑誌論文(journal article)","productIdentifier":[{"@type":"DOI","@value":"10.1177/1420326x19890376"},{"@type":"URI","@value":"https://journals.sagepub.com/doi/pdf/10.1177/1420326X19890376"},{"@type":"URI","@value":"https://journals.sagepub.com/doi/full-xml/10.1177/1420326X19890376"}],"notation":[{"@value":"Numerical sensitivity analyses for identifying rate-limiting factors influencing total energy exchange efficiency in energy recovery ventilator"}]},{"@id":"https://cir.nii.ac.jp/crid/1360004232478444544","@type":"Article","resourceType":"学術雑誌論文(journal article)","productIdentifier":[{"@type":"DOI","@value":"10.1016/j.resp.2018.02.007"},{"@type":"URI","@value":"https://api.elsevier.com/content/article/PII:S1569904817303701?httpAccept=text/xml"},{"@type":"URI","@value":"https://api.elsevier.com/content/article/PII:S1569904817303701?httpAccept=text/plain"},{"@type":"PMID","@value":"29438809"}],"notation":[{"@value":"Flow visualization through particle image velocimetry in realistic model of rhesus monkey’s upper airway"}]},{"@id":"https://cir.nii.ac.jp/crid/1360568471716052480","@type":"Article","resourceType":"学術雑誌論文(journal article)","productIdentifier":[{"@type":"DOI","@value":"10.1177/1420326x20908918"},{"@type":"URI","@value":"https://journals.sagepub.com/doi/pdf/10.1177/1420326X20908918"},{"@type":"URI","@value":"https://journals.sagepub.com/doi/full-xml/10.1177/1420326X20908918"}],"notation":[{"@value":"Correlation between formaldehyde emission characteristics in enclosed desiccators with five different geometries"}]},{"@id":"https://cir.nii.ac.jp/crid/1360004234295873152","@type":"Article","resourceType":"学術雑誌論文(journal article)","productIdentifier":[{"@type":"DOI","@value":"10.1080/17512549.2019.1588167"},{"@type":"URI","@value":"https://www.tandfonline.com/doi/pdf/10.1080/17512549.2019.1588167"}],"notation":[{"@value":"Multi-stage optimization of local environmental quality by comprehensive computer simulated person as a sensor for HVAC control"}]}],"dataSourceIdentifier":[{"@type":"KAKEN","@value":"18H03807"}],"grant":{"grantIdentifier":[{"@type":"NII","@value":"68"}],"jpcoar:fundingStream":[{"@language":"ja","@value":"基盤研究(A)"},{"@language":"en","@value":"Grant-in-Aid for Scientific Research (A)"}]},"allocationClassification":[{"notation":[{"@language":"ja","@value":"補助金"},{"@language":"en","@value":"Single-year Grants"}]}],"projectStatus":"project_closed","allocationAmount":{"totalCost":{"amount":"42250000","currency":"JPY"},"breakdownCost":[{"notation":[{"@language":"ja","@value":"直接経費"},{"@language":"en","@value":"Direct Cost"}],"amount":"32500000","currency":"JPY"},{"notation":[{"@language":"ja","@value":"間接経費"},{"@language":"en","@value":"Indirect Cost"}],"amount":"9750000","currency":"JPY"}]}}