{"@context":{"@vocab":"https://cir.nii.ac.jp/schema/1.0/","rdfs":"http://www.w3.org/2000/01/rdf-schema#","dc":"http://purl.org/dc/elements/1.1/","dcterms":"http://purl.org/dc/terms/","foaf":"http://xmlns.com/foaf/0.1/","prism":"http://prismstandard.org/namespaces/basic/2.0/","cinii":"http://ci.nii.ac.jp/ns/1.0/","datacite":"https://schema.datacite.org/meta/kernel-4/","ndl":"http://ndl.go.jp/dcndl/terms/","jpcoar":"https://github.com/JPCOAR/schema/blob/master/2.0/"},"@id":"https://cir.nii.ac.jp/crid/1360004234565201536.json","@type":"Article","productIdentifier":[{"identifier":{"@type":"DOI","@value":"10.1093/ehjci/jeu174"}},{"identifier":{"@type":"URI","@value":"http://academic.oup.com/ehjcimaging/article-pdf/16/1/23/7140548/jeu174.pdf"}},{"identifier":{"@type":"PMID","@value":"25342856"}}],"resourceType":"学術雑誌論文(journal article)","dc:title":[{"@value":"Outcomes of everolimus-eluting stent incomplete stent apposition: a serial optical coherence tomography analysis"}],"description":[{"notation":[{"@value":"The aim of the present study was to evaluate the natural course of acute incomplete stent apposition (ISA) after second-generation everolimus-eluting stent (EES) when compared with first-generation sirolimus-eluting stent (SES) by using optical coherence tomography (OCT).From the OCT substudy of the RESET trial, we identified 77 patients (EES = 38 and SES = 39) who successfully underwent serial OCT examination at post-stenting and 8-12-month follow-up. The presence of ISA was assessed in the OCT images, and ISA distance was measured from the centre of the strut blooming to the adjacent lumen border. Incomplete stent apposition was observed in all EES and SES at post-stenting, and it was persistent in 26% of EES and 38% of SES at 8-12-month follow-up. Maximum ISA distance was significantly decreased during the follow-up period in both EES (315 ± 94-110 ± 165 μm, P0.001) and SES (308 ± 119-143 ± 195 μm, P0.001). Receiver-operating curve analysis identified that the best cut-off value of OCT-estimated ISA distance at post-stenting for predicting late-persistent ISA at 8-12-month follow-up in EES and SES was355 and285 μm, respectively.The second-generation EES showed better healing of acute ISA in comparison with the first-generation SES. Optical coherence tomography can predict late-persistent ISA after DES implantation and provide useful information to optimize PCI."}]}],"creator":[{"@id":"https://cir.nii.ac.jp/crid/1380004234565201542","@type":"Researcher","foaf:name":[{"@value":"K. Shimamura"}]},{"@id":"https://cir.nii.ac.jp/crid/1380004234565201409","@type":"Researcher","foaf:name":[{"@value":"T. Kubo"}]},{"@id":"https://cir.nii.ac.jp/crid/1380004234565201543","@type":"Researcher","foaf:name":[{"@value":"T. Akasaka"}]},{"@id":"https://cir.nii.ac.jp/crid/1380004234565201664","@type":"Researcher","foaf:name":[{"@value":"K. Kozuma"}]},{"@id":"https://cir.nii.ac.jp/crid/1380004234565201536","@type":"Researcher","foaf:name":[{"@value":"K. Kimura"}]},{"@id":"https://cir.nii.ac.jp/crid/1380004234565201410","@type":"Researcher","foaf:name":[{"@value":"M. Kawamura"}]},{"@id":"https://cir.nii.ac.jp/crid/1380004234565201546","@type":"Researcher","foaf:name":[{"@value":"T. Sumiyoshi"}]},{"@id":"https://cir.nii.ac.jp/crid/1380004234565201550","@type":"Researcher","foaf:name":[{"@value":"Y. Ino"}]},{"@id":"https://cir.nii.ac.jp/crid/1380004234565201545","@type":"Researcher","foaf:name":[{"@value":"M. Yoshiyama"}]},{"@id":"https://cir.nii.ac.jp/crid/1380004234565201548","@type":"Researcher","foaf:name":[{"@value":"S. Sonoda"}]},{"@id":"https://cir.nii.ac.jp/crid/1380004234565201551","@type":"Researcher","foaf:name":[{"@value":"K. Igarashi"}]},{"@id":"https://cir.nii.ac.jp/crid/1380004234565201549","@type":"Researcher","foaf:name":[{"@value":"A. Miyazawa"}]},{"@id":"https://cir.nii.ac.jp/crid/1380004234565201411","@type":"Researcher","foaf:name":[{"@value":"H. Uzui"}]},{"@id":"https://cir.nii.ac.jp/crid/1380004234565201665","@type":"Researcher","foaf:name":[{"@value":"Y. Sakanoue"}]},{"@id":"https://cir.nii.ac.jp/crid/1380004234565201547","@type":"Researcher","foaf:name":[{"@value":"T. Shinke"}]},{"@id":"https://cir.nii.ac.jp/crid/1380004234565201413","@type":"Researcher","foaf:name":[{"@value":"Y. Morino"}]},{"@id":"https://cir.nii.ac.jp/crid/1380004234565201540","@type":"Researcher","foaf:name":[{"@value":"K. Tanabe"}]},{"@id":"https://cir.nii.ac.jp/crid/1380004234565201541","@type":"Researcher","foaf:name":[{"@value":"K. Kadota"}]},{"@id":"https://cir.nii.ac.jp/crid/1380004234565201666","@type":"Researcher","foaf:name":[{"@value":"T. Kimura"}]}],"publication":{"publicationIdentifier":[{"@type":"PISSN","@value":"20472404"},{"@type":"EISSN","@value":"20472412"}],"prism:publicationName":[{"@value":"European Heart Journal - Cardiovascular Imaging"}],"dc:publisher":[{"@value":"Oxford University Press (OUP)"}],"prism:publicationDate":"2014-10-23","prism:volume":"16","prism:number":"1","prism:startingPage":"23","prism:endingPage":"28"},"reviewed":"false","dcterms:accessRights":"http://purl.org/coar/access_right/c_abf2","url":[{"@id":"http://academic.oup.com/ehjcimaging/article-pdf/16/1/23/7140548/jeu174.pdf"}],"createdAt":"2014-10-24","modifiedAt":"2017-08-24","foaf:topic":[{"@id":"https://cir.nii.ac.jp/all?q=Male","dc:title":"Male"},{"@id":"https://cir.nii.ac.jp/all?q=Sirolimus","dc:title":"Sirolimus"},{"@id":"https://cir.nii.ac.jp/all?q=Coronary%20Stenosis","dc:title":"Coronary Stenosis"},{"@id":"https://cir.nii.ac.jp/all?q=Drug-Eluting%20Stents","dc:title":"Drug-Eluting Stents"},{"@id":"https://cir.nii.ac.jp/all?q=Middle%20Aged","dc:title":"Middle Aged"},{"@id":"https://cir.nii.ac.jp/all?q=Coronary%20Angiography","dc:title":"Coronary Angiography"},{"@id":"https://cir.nii.ac.jp/all?q=Risk%20Assessment","dc:title":"Risk Assessment"},{"@id":"https://cir.nii.ac.jp/all?q=Prosthesis%20Failure","dc:title":"Prosthesis Failure"},{"@id":"https://cir.nii.ac.jp/all?q=Treatment%20Outcome","dc:title":"Treatment Outcome"},{"@id":"https://cir.nii.ac.jp/all?q=ROC%20Curve","dc:title":"ROC Curve"},{"@id":"https://cir.nii.ac.jp/all?q=Predictive%20Value%20of%20Tests","dc:title":"Predictive Value of Tests"},{"@id":"https://cir.nii.ac.jp/all?q=Humans","dc:title":"Humans"},{"@id":"https://cir.nii.ac.jp/all?q=Female","dc:title":"Female"},{"@id":"https://cir.nii.ac.jp/all?q=Everolimus","dc:title":"Everolimus"},{"@id":"https://cir.nii.ac.jp/all?q=Prospective%20Studies","dc:title":"Prospective Studies"},{"@id":"https://cir.nii.ac.jp/all?q=Angioplasty,%20Balloon,%20Coronary","dc:title":"Angioplasty, Balloon, Coronary"},{"@id":"https://cir.nii.ac.jp/all?q=Tomography,%20Optical%20Coherence","dc:title":"Tomography, Optical Coherence"},{"@id":"https://cir.nii.ac.jp/all?q=Aged","dc:title":"Aged"},{"@id":"https://cir.nii.ac.jp/all?q=Follow-Up%20Studies","dc:title":"Follow-Up Studies"},{"@id":"https://cir.nii.ac.jp/all?q=Monitoring,%20Physiologic","dc:title":"Monitoring, Physiologic"}],"project":[{"@id":"https://cir.nii.ac.jp/crid/1040000782166804864","@type":"Project","projectIdentifier":[{"@type":"KAKEN","@value":"23591056"},{"@type":"JGN","@value":"JP23591056"},{"@type":"URI","@value":"https://kaken.nii.ac.jp/grant/KAKENHI-PROJECT-23591056/"}],"notation":[{"@language":"ja","@value":"喫煙による血管障害におけるニコチン依存度とトロンボスポンジンの関与と機序"},{"@language":"en","@value":"Role of  thrombospondin and nicotine dependence in vascular damage from smoking"}]},{"@id":"https://cir.nii.ac.jp/crid/1040282257222520960","@type":"Project","projectIdentifier":[{"@type":"KAKEN","@value":"25293182"},{"@type":"JGN","@value":"JP25293182"},{"@type":"URI","@value":"https://kaken.nii.ac.jp/grant/KAKENHI-PROJECT-25293182/"}],"notation":[{"@language":"ja","@value":"Neoatherosclerosisの本態解明と新規治療法の開発"},{"@language":"en","@value":"Elucidation of the mechanism of neoatherosclerosis"}]}],"relatedProduct":[{"@id":"https://cir.nii.ac.jp/crid/1360011146167615360","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Assessment of Coronary Arterial Thrombus by Optical Coherence Tomography"}]},{"@id":"https://cir.nii.ac.jp/crid/1360283690769397760","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@value":"Meta-Analysis of Long-Term Clinical Outcomes of Everolimus-Eluting Stents"}]},{"@id":"https://cir.nii.ac.jp/crid/1360283690954847360","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Consensus Standards for Acquisition, Measurement, and Reporting of Intravascular Optical Coherence Tomography Studies"}]},{"@id":"https://cir.nii.ac.jp/crid/1360302864783576320","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@value":"Intravascular Imaging Findings After PCI in Patients With Focal and Diffuse Coronary Artery Disease"}]},{"@id":"https://cir.nii.ac.jp/crid/1360855569914761728","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Favorable neointimal coverage in everolimus-eluting stent at 9 months after stent implantation: comparison with sirolimus-eluting stent using optical coherence tomography"}]},{"@id":"https://cir.nii.ac.jp/crid/1361137043961033344","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Incomplete Stent Apposition and Very Late Stent Thrombosis After Drug-Eluting Stent Implantation"}]},{"@id":"https://cir.nii.ac.jp/crid/1361418518538445312","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Comparison of Vascular Response After Sirolimus-Eluting Stent Implantation Between Patients With Unstable and Stable Angina Pectoris"}]},{"@id":"https://cir.nii.ac.jp/crid/1361699994012186752","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Late Stent Malapposition After Drug-Eluting Stent Implantation"}]},{"@id":"https://cir.nii.ac.jp/crid/1361699995578019456","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Examination of the In Vivo Mechanisms of Late Drug-Eluting Stent Thrombosis"}]},{"@id":"https://cir.nii.ac.jp/crid/1361699995932497920","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Vascular Tissue Reaction to Acute Malapposition in Human Coronary Arteries"}]},{"@id":"https://cir.nii.ac.jp/crid/1362262945171859840","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"The fate of incomplete stent apposition with drug-eluting stents: an optical coherence tomography-based natural history study"}]},{"@id":"https://cir.nii.ac.jp/crid/1362544420889227264","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Outcome After Acute Incomplete Sirolimus-Eluting Stent Apposition as Assessed by Serial Intravascular Ultrasound"}]},{"@id":"https://cir.nii.ac.jp/crid/1363107369650061056","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"In Vivo Comparison Between Optical Coherence Tomography and Intravascular Ultrasound for Detecting Small Degrees of In-Stent Neointima After Stent Implantation"}]},{"@id":"https://cir.nii.ac.jp/crid/1363107369966614144","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Natural consequence of post-intervention stent malapposition, thrombus, tissue prolapse, and dissection assessed by optical coherence tomography at mid-term follow-up"}]},{"@id":"https://cir.nii.ac.jp/crid/1363951794626672896","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Accuracy of Optical Coherence Tomography in the Evaluation of Neointimal Coverage After Stent Implantation"}]},{"@id":"https://cir.nii.ac.jp/crid/1390006662423576448","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@language":"en","@value":"Post-Stent Optical Coherence Tomography Findings at Index Percutaneous Coronary Intervention　― Characteristics Related to Subsequent Stent Thrombosis ―"}]},{"@id":"https://cir.nii.ac.jp/crid/1390282679445928064","@type":"Article","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@language":"ja","@value":"血管内OCT にかかわる最新の知見"},{"@language":"en","@value":"Clinical and technical update on intracoronary optical coherence tomography"},{"@language":"ja-Kana","@value":"ケッカン ナイ OCT ニ カカワル サイシン ノ チケン"}]},{"@id":"https://cir.nii.ac.jp/crid/1390282679446522880","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@language":"ja","@value":"OCTガイドPCIの現状と将来の展望"},{"@language":"en","@value":"Current status and future perspectives of optical coherence tomography in percutaneous coronary intervention"}]},{"@id":"https://cir.nii.ac.jp/crid/1390288137404734976","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@language":"en","@value":"Diagnostic Performance of High-Resolution Intravascular Ultrasound for Abnormal Post-Stent Findings After Stent Implantation　― A Comparison Study Between High-Resolution Intravascular Ultrasound and Optical Coherence Tomography ―"}]},{"@id":"https://cir.nii.ac.jp/crid/1390564227306416000","@type":"Article","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@language":"en","@value":"Role of Optical Coherence Tomography in Optimizing Percutaneous Coronary Intervention"}]},{"@id":"https://cir.nii.ac.jp/crid/1390566775155959168","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@language":"en","@value":"Comparison of Neointimal Response between Durable-Polymer Everolimus-Eluting Stent and Bioabsorbable-Polymer Everolimus-Eluting Stent for Severely Calcified Lesions Requiring Rotational Atherectomy"}]},{"@id":"https://cir.nii.ac.jp/crid/1571417126315306112","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["references"],"jpcoar:relatedTitle":[{"@language":"en","@value":"Comparison of Everolimus-Eluting and Sirolimus-Eluting Coronary Stents : 1-Year Outcomes from the Randomized Evaluation of Sirolimus-Eluting Versus Everolimus-Eluting Stent Trial (RESET)"}]},{"@id":"https://cir.nii.ac.jp/crid/2120870839910978176","@type":"OtherWorks","resourceType":"学術雑誌論文(journal article)","relationType":["hasVersion"],"jpcoar:relatedTitle":[{"@language":"en","@value":"Outcomes of everolimus-eluting stent incomplete stent apposition: a serial optical coherence tomography analysis"}]}],"dataSourceIdentifier":[{"@type":"CROSSREF","@value":"10.1093/ehjci/jeu174"},{"@type":"KAKEN","@value":"PRODUCT-14151653"},{"@type":"KAKEN","@value":"PRODUCT-15000954"},{"@type":"OPENAIRE","@value":"doi_dedup___::2d74b10be826770ae79e679c5fa46da2"},{"@type":"IRDB","@value":"oai:irdb.nii.ac.jp:00953:0006825090_isVersionOf_DOI_J4DdHP1tnQujBkWjxR0SPULlG5w"},{"@type":"CROSSREF","@value":"10.7793/jcoron.23.004_references_DOI_VeAYwSPX6TGCVw3e0e0oAQ33BtF"},{"@type":"CROSSREF","@value":"10.1253/circj.cj-20-0817_references_DOI_VeAYwSPX6TGCVw3e0e0oAQ33BtF"},{"@type":"CROSSREF","@value":"10.1161/jaha.123.032605_references_DOI_VeAYwSPX6TGCVw3e0e0oAQ33BtF"},{"@type":"CROSSREF","@value":"10.1016/j.amjcard.2015.03.059_references_DOI_VeAYwSPX6TGCVw3e0e0oAQ33BtF"},{"@type":"CROSSREF","@value":"10.1253/circj.cj-20-0759_references_DOI_VeAYwSPX6TGCVw3e0e0oAQ33BtF"},{"@type":"CROSSREF","@value":"10.7793/jcad.25.008_references_DOI_VeAYwSPX6TGCVw3e0e0oAQ33BtF"},{"@type":"CROSSREF","@value":"10.1536/ihj.19-648_references_DOI_VeAYwSPX6TGCVw3e0e0oAQ33BtF"},{"@type":"CROSSREF","@value":"10.7793/jcoron.22.15-00018_references_DOI_VeAYwSPX6TGCVw3e0e0oAQ33BtF"}]}