{"@context":{"@vocab":"https://cir.nii.ac.jp/schema/1.0/","rdfs":"http://www.w3.org/2000/01/rdf-schema#","dc":"http://purl.org/dc/elements/1.1/","dcterms":"http://purl.org/dc/terms/","foaf":"http://xmlns.com/foaf/0.1/","prism":"http://prismstandard.org/namespaces/basic/2.0/","cinii":"http://ci.nii.ac.jp/ns/1.0/","datacite":"https://schema.datacite.org/meta/kernel-4/","ndl":"http://ndl.go.jp/dcndl/terms/","jpcoar":"https://github.com/JPCOAR/schema/blob/master/2.0/"},"@id":"https://cir.nii.ac.jp/crid/1360011142935705472.json","@type":"Article","productIdentifier":[{"identifier":{"@type":"DOI","@value":"10.1175/jas-d-12-0227.1"}},{"identifier":{"@type":"URI","@value":"http://journals.ametsoc.org/jas/article-pdf/70/5/1342/3871952/jas-d-12-0227_1.pdf"}}],"dc:title":[{"@value":"The Effects of Explicit versus Parameterized Convection on the MJO in a Large-Domain High-Resolution Tropical Case Study. Part I: Characterization of Large-Scale Organization and Propagation*"}],"description":[{"type":"abstract","notation":[{"@value":"<jats:title>Abstract</jats:title>\n               <jats:p>High-resolution simulations over a large tropical domain (~20°S–20°N, 42°E–180°) using both explicit and parameterized convection are analyzed and compared to observations during a 10-day case study of an active Madden–Julian oscillation (MJO) event. The parameterized convection model simulations at both 40- and 12-km grid spacing have a very weak MJO signal and little eastward propagation. A 4-km explicit convection simulation using Smagorinsky subgrid mixing in the vertical and horizontal dimensions exhibits the best MJO strength and propagation speed. Explicit convection simulations at 12 km also perform much better than the 12-km parameterized convection run, suggesting that the convection scheme, rather than horizontal resolution, is key for these MJO simulations. Interestingly, a 4-km explicit convection simulation using the conventional boundary layer scheme for vertical subgrid mixing (but still using Smagorinsky horizontal mixing) completely loses the large-scale MJO organization, showing that relatively high resolution with explicit convection does not guarantee a good MJO simulation. Models with a good MJO representation have a more realistic relationship between lower-free-tropospheric moisture and precipitation, supporting the idea that the moisture–convection feedback is a key process for MJO propagation. There is also increased generation of available potential energy and conversion of that energy into kinetic energy in models with a more realistic MJO, which is related to larger zonal variance in convective heating and vertical velocity, larger zonal temperature variance around 200 hPa, and larger correlations between temperature and ascent (and between temperature and diabatic heating) between 500 and 400 hPa.</jats:p>"}]}],"creator":[{"@id":"https://cir.nii.ac.jp/crid/1380011142935705474","@type":"Researcher","foaf:name":[{"@value":"Christopher E. Holloway"}],"jpcoar:affiliationName":[{"@value":"NCAS-Climate, Department of Meteorology, University of Reading, Reading, United Kingdom"}]},{"@id":"https://cir.nii.ac.jp/crid/1380011142935705472","@type":"Researcher","foaf:name":[{"@value":"Steven J. Woolnough"}],"jpcoar:affiliationName":[{"@value":"NCAS-Climate, Department of Meteorology, University of Reading, Reading, United Kingdom"}]},{"@id":"https://cir.nii.ac.jp/crid/1380011142935705473","@type":"Researcher","foaf:name":[{"@value":"Grenville M. S. Lister"}],"jpcoar:affiliationName":[{"@value":"NCAS-CMS, Department of Meteorology, University of Reading, Reading, United Kingdom"}]}],"publication":{"publicationIdentifier":[{"@type":"PISSN","@value":"00224928"},{"@type":"EISSN","@value":"15200469"}],"prism:publicationName":[{"@value":"Journal of the Atmospheric Sciences"}],"dc:publisher":[{"@value":"American Meteorological Society"}],"prism:publicationDate":"2013-04-23","prism:volume":"70","prism:number":"5","prism:startingPage":"1342","prism:endingPage":"1369"},"reviewed":"false","url":[{"@id":"http://journals.ametsoc.org/jas/article-pdf/70/5/1342/3871952/jas-d-12-0227_1.pdf"}],"createdAt":"2012-11-13","modifiedAt":"2020-12-07","relatedProduct":[{"@id":"https://cir.nii.ac.jp/crid/1360004229809165440","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@value":"Initiation Processes of the Tropical Intraseasonal Variability Simulated in an Aqua‐Planet Experiment: What is the Intrinsic Mechanism for MJO Onset?"}]},{"@id":"https://cir.nii.ac.jp/crid/1360017280648570752","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@value":"Sensitivity of the Horizontal Scale of Convective Self‐Aggregation to Sea Surface Temperature in Radiative Convective Equilibrium Experiments Using a Global Nonhydrostatic Model"}]},{"@id":"https://cir.nii.ac.jp/crid/1360283689325751552","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@value":"Intraseasonal variability and tropical cyclogenesis in the western North Pacific simulated by a global nonhydrostatic atmospheric model"}]},{"@id":"https://cir.nii.ac.jp/crid/1360283690280015616","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@value":"Tropical intraseasonal oscillation simulated in an AMIP-type experiment by NICAM"}]},{"@id":"https://cir.nii.ac.jp/crid/1360298757200378112","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@value":"Deceleration of Madden–Julian Oscillation Speed in NICAM AMIP‐Type Simulation Associated With Biases in the Walker Circulation Strength"}]},{"@id":"https://cir.nii.ac.jp/crid/1360572092465743616","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@value":"Diversity of the Madden–Julian Oscillation: Initiation Region Modulated by the Interaction between the Intraseasonal and Interannual Variabilities"}]},{"@id":"https://cir.nii.ac.jp/crid/1360846641733932928","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@value":"Madden–Julian Oscillation prediction skill of a new-generation global model demonstrated using a supercomputer"}]},{"@id":"https://cir.nii.ac.jp/crid/1390282680199019264","@type":"Article","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@language":"en","@value":"Impact of Tropical Disturbance on the Indian Summer Monsoon Onset Simulated by a Global Cloud-System-Resolving Model"}]},{"@id":"https://cir.nii.ac.jp/crid/1390282680199065216","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@language":"en","@value":"Topographical Effects on Internally Produced MJO-Like Disturbances in an Aqua-Planet Version of NICAM"}]},{"@id":"https://cir.nii.ac.jp/crid/1390282681480168192","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@language":"en","@value":"Relationship between Cumulus Activity and Environmental Moisture during the CINDY2011/DYNAMO Field Experiment as Revealed from Convection-Resolving Simulations"}]},{"@id":"https://cir.nii.ac.jp/crid/1390282681481473792","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@language":"en","@value":"A 20-Year Climatology of a NICAM AMIP-Type Simulation"}]},{"@id":"https://cir.nii.ac.jp/crid/2051151842089639168","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@value":"The Non-hydrostatic Icosahedral Atmospheric Model : description and development"}]}],"dataSourceIdentifier":[{"@type":"CROSSREF","@value":"10.1175/jas-d-12-0227.1"},{"@type":"CROSSREF","@value":"10.1002/2017ms001243_references_DOI_Uo9yz9s8HNePbHTMrikrPjokVat"},{"@type":"CROSSREF","@value":"10.1007/s00382-016-3219-z_references_DOI_Uo9yz9s8HNePbHTMrikrPjokVat"},{"@type":"CROSSREF","@value":"10.2151/jmsj.2015-024_references_DOI_Uo9yz9s8HNePbHTMrikrPjokVat"},{"@type":"CROSSREF","@value":"10.1029/2021ms002636_references_DOI_Uo9yz9s8HNePbHTMrikrPjokVat"},{"@type":"CROSSREF","@value":"10.1002/2014gl062479_references_DOI_Uo9yz9s8HNePbHTMrikrPjokVat"},{"@type":"CROSSREF","@value":"10.1186/s40645-014-0018-1_references_DOI_Uo9yz9s8HNePbHTMrikrPjokVat"},{"@type":"CROSSREF","@value":"10.2151/jmsj.2015-035_references_DOI_Uo9yz9s8HNePbHTMrikrPjokVat"},{"@type":"CROSSREF","@value":"10.1029/2022gl098628_references_DOI_Uo9yz9s8HNePbHTMrikrPjokVat"},{"@type":"CROSSREF","@value":"10.1038/ncomms4769_references_DOI_Uo9yz9s8HNePbHTMrikrPjokVat"},{"@type":"CROSSREF","@value":"10.2151/sola.2015-038_references_DOI_Uo9yz9s8HNePbHTMrikrPjokVat"},{"@type":"CROSSREF","@value":"10.1175/jcli-d-20-0688.1_references_DOI_Uo9yz9s8HNePbHTMrikrPjokVat"},{"@type":"CROSSREF","@value":"10.2151/sola.2015-020_references_DOI_Uo9yz9s8HNePbHTMrikrPjokVat"}]}