{"@context":{"@vocab":"https://cir.nii.ac.jp/schema/1.0/","rdfs":"http://www.w3.org/2000/01/rdf-schema#","dc":"http://purl.org/dc/elements/1.1/","dcterms":"http://purl.org/dc/terms/","foaf":"http://xmlns.com/foaf/0.1/","prism":"http://prismstandard.org/namespaces/basic/2.0/","cinii":"http://ci.nii.ac.jp/ns/1.0/","datacite":"https://schema.datacite.org/meta/kernel-4/","ndl":"http://ndl.go.jp/dcndl/terms/","jpcoar":"https://github.com/JPCOAR/schema/blob/master/2.0/"},"@id":"https://cir.nii.ac.jp/crid/1360848655219950720.json","@type":"Article","productIdentifier":[{"identifier":{"@type":"DOI","@value":"10.1002/rcs.1530"}},{"identifier":{"@type":"URI","@value":"https://api.wiley.com/onlinelibrary/tdm/v1/articles/10.1002%2Frcs.1530"}},{"identifier":{"@type":"URI","@value":"https://onlinelibrary.wiley.com/doi/pdf/10.1002/rcs.1530"}},{"identifier":{"@type":"PMID","@value":"24106094"}}],"resourceType":"学術雑誌論文(journal article)","dc:title":[{"@value":"Three‐dimensional corrective osteotomy using a patient‐specific osteotomy guide and bone plate based on a computer simulation system: accuracy analysis in a cadaver study"}],"description":[{"type":"abstract","notation":[{"@value":"<jats:title>Abstract</jats:title><jats:sec><jats:title>Background</jats:title><jats:p>The accuracy of three‐dimensional (3‐D) corrective osteotomy using a patient‐specific osteotomy guide and bone plate based on computer simulation was investigated.</jats:p></jats:sec><jats:sec><jats:title>Methods</jats:title><jats:p>Six fresh‐frozen cadaver upper limbs were used. A patient‐specific osteotomy guide designed to realize a preplanned osteotomy was set on the distal humerus and distal radius, and the error in the setting location was evaluated. After the osteotomy, the surgical site was fixed using a patient‐specific bone plate designed to exactly fit the anatomical shape of the postoperative bone model. The postoperative results were compared with the preoperative simulation.</jats:p></jats:sec><jats:sec><jats:title>Results</jats:title><jats:p>The errors in the guide location on the humerus and radius were <1.5° and 1.0 mm and <1.0° and 1.0 mm, respectively. The plate fixation errors of the humerus and radius were <2.0° and 1.5 mm and <1.0° and 1.0 mm, respectively.</jats:p></jats:sec><jats:sec><jats:title>Conclusions</jats:title><jats:p>The system is sufficiently feasible to realize precise 3‐D deformity correction of a limb. Copyright © 2013 John Wiley & Sons, Ltd.</jats:p></jats:sec>"}]}],"creator":[{"@id":"https://cir.nii.ac.jp/crid/1380848655219950858","@type":"Researcher","foaf:name":[{"@value":"Shinsuke Omori"}],"jpcoar:affiliationName":[{"@value":"Department of Orthopaedic Surgery Osaka University Graduate School of Medicine  2‐2, Yamada‐oka Suita Osaka 565‐0871 Japan"}]},{"@id":"https://cir.nii.ac.jp/crid/1420564276174922880","@type":"Researcher","personIdentifier":[{"@type":"KAKEN_RESEARCHERS","@value":"50335361"},{"@type":"NRID","@value":"1000050335361"},{"@type":"ORCID","@value":"0000-0001-5628-5891"},{"@type":"NRID","@value":"9000003167418"},{"@type":"NRID","@value":"9000002092438"},{"@type":"NRID","@value":"9000378067829"},{"@type":"NRID","@value":"9000010723331"},{"@type":"NRID","@value":"9000255689683"},{"@type":"NRID","@value":"9000406322735"},{"@type":"NRID","@value":"9000410053097"},{"@type":"NRID","@value":"9000403167185"},{"@type":"NRID","@value":"9000255979285"},{"@type":"NRID","@value":"9000409808259"},{"@type":"NRID","@value":"9000255987082"},{"@type":"NRID","@value":"9000406064589"},{"@type":"NRID","@value":"9000258330889"},{"@type":"NRID","@value":"9000347667169"},{"@type":"NRID","@value":"9000413756025"},{"@type":"NRID","@value":"9000258330081"},{"@type":"NRID","@value":"9000282413531"},{"@type":"NRID","@value":"9000262367161"},{"@type":"NRID","@value":"9000016383694"},{"@type":"NRID","@value":"9000399258608"},{"@type":"NRID","@value":"9000018778305"},{"@type":"NRID","@value":"9000413387763"},{"@type":"NRID","@value":"9000324986852"},{"@type":"NRID","@value":"9000398038834"},{"@type":"NRID","@value":"9000412173845"},{"@type":"NRID","@value":"9000403408531"},{"@type":"RESEARCHMAP","@value":"https://researchmap.jp/tmurase-osk"}],"foaf:name":[{"@value":"Tsuyoshi Murase"}],"jpcoar:affiliationName":[{"@value":"Department of Orthopaedic Surgery Osaka University Graduate School of Medicine  2‐2, Yamada‐oka Suita Osaka 565‐0871 Japan"}]},{"@id":"https://cir.nii.ac.jp/crid/1380848655219950857","@type":"Researcher","foaf:name":[{"@value":"Toshiyuki Kataoka"}],"jpcoar:affiliationName":[{"@value":"Department of Orthopaedic Surgery Osaka University Graduate School of Medicine  2‐2, Yamada‐oka Suita Osaka 565‐0871 Japan"}]},{"@id":"https://cir.nii.ac.jp/crid/1380848655219950851","@type":"Researcher","foaf:name":[{"@value":"Yohei Kawanishi"}],"jpcoar:affiliationName":[{"@value":"Department of Orthopaedic Surgery Osaka University Graduate School of Medicine  2‐2, Yamada‐oka Suita Osaka 565‐0871 Japan"}]},{"@id":"https://cir.nii.ac.jp/crid/1380848655219950854","@type":"Researcher","foaf:name":[{"@value":"Keiichiro Oura"}],"jpcoar:affiliationName":[{"@value":"Department of Orthopaedic Surgery Osaka University Graduate School of Medicine  2‐2, Yamada‐oka Suita Osaka 565‐0871 Japan"}]},{"@id":"https://cir.nii.ac.jp/crid/1380848655219950592","@type":"Researcher","foaf:name":[{"@value":"Junichi Miyake"}],"jpcoar:affiliationName":[{"@value":"Department of Orthopaedic Surgery Osaka University Graduate School of Medicine  2‐2, Yamada‐oka Suita Osaka 565‐0871 Japan"}]},{"@id":"https://cir.nii.ac.jp/crid/1380848655219950596","@type":"Researcher","foaf:name":[{"@value":"Hiroyuki Tanaka"}],"jpcoar:affiliationName":[{"@value":"Department of Orthopaedic Surgery Osaka University Graduate School of Medicine  2‐2, Yamada‐oka Suita Osaka 565‐0871 Japan"}]},{"@id":"https://cir.nii.ac.jp/crid/1380848655219950723","@type":"Researcher","foaf:name":[{"@value":"Hideki Yoshikawa"}],"jpcoar:affiliationName":[{"@value":"Department of Orthopaedic Surgery Osaka University Graduate School of Medicine  2‐2, Yamada‐oka Suita Osaka 565‐0871 Japan"}]}],"publication":{"publicationIdentifier":[{"@type":"PISSN","@value":"14785951"},{"@type":"EISSN","@value":"1478596X"}],"prism:publicationName":[{"@value":"The International Journal of Medical Robotics and Computer Assisted Surgery"}],"dc:publisher":[{"@value":"Wiley"}],"prism:publicationDate":"2013-09-18","prism:volume":"10","prism:number":"2","prism:startingPage":"196","prism:endingPage":"202"},"reviewed":"false","dc:rights":["http://onlinelibrary.wiley.com/termsAndConditions#vor"],"url":[{"@id":"https://api.wiley.com/onlinelibrary/tdm/v1/articles/10.1002%2Frcs.1530"},{"@id":"https://onlinelibrary.wiley.com/doi/pdf/10.1002/rcs.1530"}],"createdAt":"2013-10-08","modifiedAt":"2023-10-05","foaf:topic":[{"@id":"https://cir.nii.ac.jp/all?q=Aged,%2080%20and%20over","dc:title":"Aged, 80 and over"},{"@id":"https://cir.nii.ac.jp/all?q=Male","dc:title":"Male"},{"@id":"https://cir.nii.ac.jp/all?q=Models,%20Anatomic","dc:title":"Models, Anatomic"},{"@id":"https://cir.nii.ac.jp/all?q=Patient-Specific%20Modeling","dc:title":"Patient-Specific Modeling"},{"@id":"https://cir.nii.ac.jp/all?q=Equipment%20Design","dc:title":"Equipment Design"},{"@id":"https://cir.nii.ac.jp/all?q=Humerus","dc:title":"Humerus"},{"@id":"https://cir.nii.ac.jp/all?q=Osteotomy","dc:title":"Osteotomy"},{"@id":"https://cir.nii.ac.jp/all?q=Radius","dc:title":"Radius"},{"@id":"https://cir.nii.ac.jp/all?q=Imaging,%20Three-Dimensional","dc:title":"Imaging, Three-Dimensional"},{"@id":"https://cir.nii.ac.jp/all?q=Surgery,%20Computer-Assisted","dc:title":"Surgery, Computer-Assisted"},{"@id":"https://cir.nii.ac.jp/all?q=Cadaver","dc:title":"Cadaver"},{"@id":"https://cir.nii.ac.jp/all?q=Humans","dc:title":"Humans"},{"@id":"https://cir.nii.ac.jp/all?q=Computer%20Simulation","dc:title":"Computer Simulation"},{"@id":"https://cir.nii.ac.jp/all?q=Female","dc:title":"Female"},{"@id":"https://cir.nii.ac.jp/all?q=Tomography,%20X-Ray%20Computed","dc:title":"Tomography, X-Ray Computed"},{"@id":"https://cir.nii.ac.jp/all?q=Bone%20Plates","dc:title":"Bone Plates"},{"@id":"https://cir.nii.ac.jp/all?q=Aged","dc:title":"Aged"}],"project":[{"@id":"https://cir.nii.ac.jp/crid/1040000782153118080","@type":"Project","projectIdentifier":[{"@type":"KAKEN","@value":"23390362"},{"@type":"JGN","@value":"JP23390362"},{"@type":"URI","@value":"https://kaken.nii.ac.jp/grant/KAKENHI-PROJECT-23390362/"}],"notation":[{"@language":"ja","@value":"新世代手術デバイスによる超高精度四肢矯正方法の開発"},{"@language":"en","@value":"Development of high accuracy deformity correction system for the limb"}]}],"relatedProduct":[{"@id":"https://cir.nii.ac.jp/crid/1360004231195309696","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@value":"A comparison of corrective osteotomies using dorsal and volar fixation for malunited distal radius fractures"}]},{"@id":"https://cir.nii.ac.jp/crid/1360004232308745472","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@value":"Morphology and kinematics studies of the upper extremity and its clinical application in deformity correction"}]},{"@id":"https://cir.nii.ac.jp/crid/1360009142465747968","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@value":"Three-dimensional evaluations of preoperative planning reproducibility for the osteosynthesis of distal radius fractures"}]},{"@id":"https://cir.nii.ac.jp/crid/1360009142708012160","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@value":"Three-Dimensional Corrective Osteotomy for Malunited Fractures of the Upper Extremity Using Patient-Matched Instruments"}]},{"@id":"https://cir.nii.ac.jp/crid/1360011145733548032","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"A CAD/CAM-prototyped anatomical condylar prosthesis connected to a custom-made bone plate to support a fibula free flap"}]},{"@id":"https://cir.nii.ac.jp/crid/1360285707300821248","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Three-dimensional analysis of cubitus varus deformity after supracondylar fractures of the humerus"}]},{"@id":"https://cir.nii.ac.jp/crid/1360567181455356032","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Distal Radius Osteotomy with Volar Locking Plates Based on Computer Simulation"}]},{"@id":"https://cir.nii.ac.jp/crid/1360567182277626752","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@value":"Postoperative accuracy analysis of three-dimensional corrective osteotomy for cubitus varus deformity with a custom-made surgical guide based on computer simulation"}]},{"@id":"https://cir.nii.ac.jp/crid/1360567186683354496","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Three-dimensional deformity analysis of malunited distal radius fractures and their influence on wrist and forearm motion"}]},{"@id":"https://cir.nii.ac.jp/crid/1360567188284393984","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Computer-Assisted Corrective Osteotomy for Malunited Diaphyseal Forearm Fractures"}]},{"@id":"https://cir.nii.ac.jp/crid/1360576118720439296","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@value":"Arthroscopic Debridement of Elbow Osteoarthritis Using CT‐Based Computer‐Aided Navigation Systems Is Accurate"}]},{"@id":"https://cir.nii.ac.jp/crid/1360848661105753856","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@value":"Surgical Technique of Corrective Osteotomy for Malunited Distal Radius Fracture Using the Computer-Simulated Patient Matched Instrument"}]},{"@id":"https://cir.nii.ac.jp/crid/1360853567469104768","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@value":"Utility of a 3-dimensionally printed color-coded bone model to visualize impinging osteophytes for arthroscopic débridement arthroplasty in elbow osteoarthritis"}]},{"@id":"https://cir.nii.ac.jp/crid/1360857593719344896","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@value":"Intra-articular corrective osteotomy for intra-articular malunion of distal radius fracture using three-dimensional surgical computer simulation and patient-matched instrument"}]},{"@id":"https://cir.nii.ac.jp/crid/1360857593742316544","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@value":"An image fusion system for corrective osteotomy of distal radius malunion"}]},{"@id":"https://cir.nii.ac.jp/crid/1360869856045473408","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@value":"Simultaneous Intra-articular and Extra-articular Corrective Osteotomies Using a Patient-Matched Surgical Guide and Plate for Malunion After Distal Radius Fractures: A Report of Two Cases"}]},{"@id":"https://cir.nii.ac.jp/crid/1361137043974414976","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Three-Dimensional Corrective Osteotomy of Malunited Fractures of the Upper Extremity with Use of a Computer Simulation System"}]},{"@id":"https://cir.nii.ac.jp/crid/1361418518517407616","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Outcome after Corrective Osteotomy for Malunited Fractures of the Distal End of the Radius"}]},{"@id":"https://cir.nii.ac.jp/crid/1361418521313746944","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Accuracy of corrective osteotomy using a custom-designed device based on a novel computer simulation system"}]},{"@id":"https://cir.nii.ac.jp/crid/1361699994369029504","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Corrective osteotomy for cubitus varus in middle-aged patients"}]},{"@id":"https://cir.nii.ac.jp/crid/1361699996372924544","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Reconstructive Procedures for Malunion and Traumatic Arthritis"}]},{"@id":"https://cir.nii.ac.jp/crid/1361975841909249536","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@value":"Validation of the registration accuracy of navigation-assisted arthroscopic débridement for elbow osteoarthritis"}]},{"@id":"https://cir.nii.ac.jp/crid/1361981468639376128","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Corrective Osteotomy for Cubitus Varus Deformity"}]},{"@id":"https://cir.nii.ac.jp/crid/1361981469166569600","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Surgery for posttraumatic wrist deformity: Radial osteotomy and/or ulnar shortening in 16 Colles' fractures"}]},{"@id":"https://cir.nii.ac.jp/crid/1361981470109449088","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"VARUS DEFORMITY OF THE ELBOW FOLLOWING SUPRACONDYLAR FRACTURES OF THE HUMERUS IN CHILDREN"}]},{"@id":"https://cir.nii.ac.jp/crid/1362262944098442496","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Three-dimensional morphological analysis of humeral heads"}]},{"@id":"https://cir.nii.ac.jp/crid/1362544420805800064","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Angular deformities and forearm function"}]},{"@id":"https://cir.nii.ac.jp/crid/1362544421031602176","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Corrective Osteotomies in Malunions of the Distal Radius"}]},{"@id":"https://cir.nii.ac.jp/crid/1363107368995002496","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"An algorithmic overview of surface registration techniques for medical imaging"}]},{"@id":"https://cir.nii.ac.jp/crid/1363107369007104000","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"ISB recommendation on definitions of joint coordinate systems of various joints for the reporting of human joint motion—Part II: shoulder, elbow, wrist and hand"}]},{"@id":"https://cir.nii.ac.jp/crid/1363107369063920000","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Complications of Collesʼ fractures."}]},{"@id":"https://cir.nii.ac.jp/crid/1363670318924577408","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Morphological iterative closest point algorithm"}]},{"@id":"https://cir.nii.ac.jp/crid/1363670319521530368","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Comparison of three dimensional and radiographic measurements in the analysis of distal radius malunion"}]},{"@id":"https://cir.nii.ac.jp/crid/1363670320141721600","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"The effect on supination-pronation of angular malalignment of fractures of both bones of the forearm."}]},{"@id":"https://cir.nii.ac.jp/crid/1364233269091691776","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Surgical treatment of displaced supracondylar fractures of the humerus in children. Analysis of fifty-two cases followed for five to fifteen years."}]},{"@id":"https://cir.nii.ac.jp/crid/1370016861845470977","@type":"Product","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Patient‐tailored plate for bone fixation and accurate 3D positioning in corrective osteotomy"}]},{"@id":"https://cir.nii.ac.jp/crid/1390011231105091712","@type":"Article","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@language":"en","@value":"Clinical Application of Additive Manufacturing to Surgical Devices"},{"@language":"ja","@value":"積層造形（Additive Manufacturing: AM）の手術器具への応用"}]},{"@id":"https://cir.nii.ac.jp/crid/1570009750075033600","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@language":"en","@value":"Malunion of the distal radius : current approach to management"}]},{"@id":"https://cir.nii.ac.jp/crid/1573950400934458240","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@language":"en","@value":"Displaced supracondylar fractures of the humerus in children"},{"@value":"Displaced supracondylar fractures of the humerus in children. Audit changes practice"}]}],"dataSourceIdentifier":[{"@type":"CROSSREF","@value":"10.1002/rcs.1530"},{"@type":"KAKEN","@value":"PRODUCT-20434458"},{"@type":"OPENAIRE","@value":"doi_dedup___::d1f33d3045149c8124f73e97e38994fe"},{"@type":"CROSSREF","@value":"10.1007/s00264-018-3972-1_references_DOI_YnnP2qBVhNdpRuchpwvYIXU9j37"},{"@type":"CROSSREF","@value":"10.1186/s13018-021-02278-9_references_DOI_YnnP2qBVhNdpRuchpwvYIXU9j37"},{"@type":"CROSSREF","@value":"10.2106/jbjs.18.00765_references_DOI_YnnP2qBVhNdpRuchpwvYIXU9j37"},{"@type":"CROSSREF","@value":"10.1016/j.jse.2019.06.009_references_DOI_YnnP2qBVhNdpRuchpwvYIXU9j37"},{"@type":"CROSSREF","@value":"10.1016/j.asmr.2021.07.025_references_DOI_YnnP2qBVhNdpRuchpwvYIXU9j37"},{"@type":"CROSSREF","@value":"10.7791/jspmee.10.175_references_DOI_YnnP2qBVhNdpRuchpwvYIXU9j37"},{"@type":"CROSSREF","@value":"10.1142/s2424835516400051_references_DOI_YnnP2qBVhNdpRuchpwvYIXU9j37"},{"@type":"CROSSREF","@value":"10.1016/j.jse.2020.12.002_references_DOI_YnnP2qBVhNdpRuchpwvYIXU9j37"},{"@type":"CROSSREF","@value":"10.1016/j.jos.2019.11.005_references_DOI_YnnP2qBVhNdpRuchpwvYIXU9j37"},{"@type":"CROSSREF","@value":"10.1186/s12938-021-00901-8_references_DOI_YnnP2qBVhNdpRuchpwvYIXU9j37"},{"@type":"CROSSREF","@value":"10.5435/jaaosglobal-d-24-00328_references_DOI_YnnP2qBVhNdpRuchpwvYIXU9j37"},{"@type":"CROSSREF","@value":"10.1016/j.jos.2018.05.013_references_DOI_YnnP2qBVhNdpRuchpwvYIXU9j37"},{"@type":"CROSSREF","@value":"10.1016/j.jse.2014.08.020_references_DOI_YnnP2qBVhNdpRuchpwvYIXU9j37"}]}