{"@context":{"@vocab":"https://cir.nii.ac.jp/schema/1.0/","rdfs":"http://www.w3.org/2000/01/rdf-schema#","dc":"http://purl.org/dc/elements/1.1/","dcterms":"http://purl.org/dc/terms/","foaf":"http://xmlns.com/foaf/0.1/","prism":"http://prismstandard.org/namespaces/basic/2.0/","cinii":"http://ci.nii.ac.jp/ns/1.0/","datacite":"https://schema.datacite.org/meta/kernel-4/","ndl":"http://ndl.go.jp/dcndl/terms/","jpcoar":"https://github.com/JPCOAR/schema/blob/master/2.0/"},"@id":"https://cir.nii.ac.jp/crid/1361981470113997696.json","@type":"Article","productIdentifier":[{"identifier":{"@type":"DOI","@value":"10.1002/bem.20005"}},{"identifier":{"@type":"URI","@value":"https://api.wiley.com/onlinelibrary/tdm/v1/articles/10.1002%2Fbem.20005"}},{"identifier":{"@type":"URI","@value":"https://onlinelibrary.wiley.com/doi/pdf/10.1002/bem.20005"}}],"dc:title":[{"@value":"Electric discharge plasmas influence attachment of cultured CHO K1 cells"}],"description":[{"type":"abstract","notation":[{"@value":"<jats:title>Abstract</jats:title><jats:p>Non‐thermal plasmas can be generated by electric discharges in gases. These plasmas are reactive media, capable of superficial treatment of various materials. A novel non‐thermal atmospheric plasma source (plasma needle) has been developed and tested. Plasma appears at the end of a metal pin as a submillimetre glow. We investigate the possibility of applying the plasma needle directly to living tissues; the final goal is controlled cell treatment in microsurgery. To resolve plasma effects on cells, we study cultured Chinese hamster ovarian cells (CHO‐K1) as a model system. When these are exposed to the plasma, instantaneous detachment of cells from the surface and loss of cell–cell interaction is observed. This occurs in the power range 0.1–0.2 W. Cell viability is assessed using propidium iodide (PI) and cell tracker green (CTG) fluorescent staining utilizing confocal laser scanning microscopy (CLSM). Detached cells remain alive. Use of higher doses (plasma power >0.2 W) results in cell necrosis. In all cases, plasma‐influenced cells are strictly localized in submillimetre areas, while no reaction in surrounding cells is observed. Due to its extreme precision, plasma treatment may be applicable in refined tissue modification. Bioelectromagnetics 25:362–368, 2004. © 2004 Wiley‐Liss, Inc.</jats:p>"}]}],"creator":[{"@id":"https://cir.nii.ac.jp/crid/1380285529186088585","@type":"Researcher","foaf:name":[{"@value":"I.E. Kieft"}]},{"@id":"https://cir.nii.ac.jp/crid/1381981470113997697","@type":"Researcher","foaf:name":[{"@value":"J.L.V. Broers"}]},{"@id":"https://cir.nii.ac.jp/crid/1380016979123159040","@type":"Researcher","foaf:name":[{"@value":"V. Caubet‐Hilloutou"}]},{"@id":"https://cir.nii.ac.jp/crid/1381981470113997698","@type":"Researcher","foaf:name":[{"@value":"D.W. Slaaf"}]},{"@id":"https://cir.nii.ac.jp/crid/1381981470113997699","@type":"Researcher","foaf:name":[{"@value":"F.C.S. Ramaekers"}]},{"@id":"https://cir.nii.ac.jp/crid/1381981470113997701","@type":"Researcher","foaf:name":[{"@value":"E. Stoffels"}]}],"publication":{"publicationIdentifier":[{"@type":"PISSN","@value":"01978462"},{"@type":"EISSN","@value":"1521186X"}],"prism:publicationName":[{"@value":"Bioelectromagnetics"}],"dc:publisher":[{"@value":"Wiley"}],"prism:publicationDate":"2004-06-09","prism:volume":"25","prism:number":"5","prism:startingPage":"362","prism:endingPage":"368"},"reviewed":"false","dc:rights":["http://onlinelibrary.wiley.com/termsAndConditions#vor"],"url":[{"@id":"https://api.wiley.com/onlinelibrary/tdm/v1/articles/10.1002%2Fbem.20005"},{"@id":"https://onlinelibrary.wiley.com/doi/pdf/10.1002/bem.20005"}],"createdAt":"2004-06-09","modifiedAt":"2023-11-16","relatedProduct":[{"@id":"https://cir.nii.ac.jp/crid/1050001338813863808","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@language":"en","@value":"Molecular mechanisms of non-thermal plasma-induced effects in cancer cells"}]},{"@id":"https://cir.nii.ac.jp/crid/1360002218333279104","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@value":"Helium‐based cold atmospheric plasma‐induced reactive oxygen species‐mediated apoptotic pathway attenuated by platinum nanoparticles"}]},{"@id":"https://cir.nii.ac.jp/crid/1360004239513337856","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@value":"New Hopes for Plasma-Based Cancer Treatment"}]},{"@id":"https://cir.nii.ac.jp/crid/1360284924860754688","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@value":"Highly efficient and minimally invasive transfection using time-controlled irradiation of atmospheric-pressure plasma"}]},{"@id":"https://cir.nii.ac.jp/crid/1360285710398291968","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@value":"Plasma Medical Science for Cancer Therapy: Toward Cancer Therapy Using Nonthermal Atmospheric Pressure Plasma"}]},{"@id":"https://cir.nii.ac.jp/crid/1360298757186235776","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@value":"Current understanding of plasma-activated solutions for potential cancer therapy"}]},{"@id":"https://cir.nii.ac.jp/crid/1360302864791261184","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@value":"Influence of electric potential-induced by atmospheric pressure plasma on cell response"}]},{"@id":"https://cir.nii.ac.jp/crid/1360565166782770816","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@value":"Cold atmospheric helium plasma causes synergistic enhancement in cell death with hyperthermia and an additive enhancement with radiation"}]},{"@id":"https://cir.nii.ac.jp/crid/1360567182038627712","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@value":"Plasma with high electron density and plasma-activated medium for cancer treatment"}]},{"@id":"https://cir.nii.ac.jp/crid/1360567185823219456","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@value":"Improvement of cell membrane permeability using a cell-solution electrode for generating atmospheric-pressure plasma"}]},{"@id":"https://cir.nii.ac.jp/crid/1360846640465794304","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@value":"State of the art in medical applications using non-thermal atmospheric pressure plasma"}]},{"@id":"https://cir.nii.ac.jp/crid/1360846644026473856","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@value":"Effect of Plasma-Activated Lactated Ringer’s Solution on Pancreatic Cancer Cells In Vitro and In Vivo"}]},{"@id":"https://cir.nii.ac.jp/crid/1360848661915706624","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@value":"Intraperitoneal Administration of Plasma-Activated Medium: Proposal of a Novel Treatment Option for Peritoneal Metastasis From Gastric Cancer"}]},{"@id":"https://cir.nii.ac.jp/crid/1360857593776220416","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@value":"Plasma‐activated Ringer's lactate solution inhibits the cellular respiratory system in HeLa cells"}]},{"@id":"https://cir.nii.ac.jp/crid/1390282679647652608","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@language":"en","@value":"Future perspective of strategic non-thermal plasma therapy for cancer treatment"}]},{"@id":"https://cir.nii.ac.jp/crid/1520290883723720064","@type":"Article","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@value":"Surface modification process of contact lens using three-phase AC excited nonequilibrium atmospheric pressure Ar plasma"},{"@language":"ja-Kana","@value":"Surface modification process of contact lens using three phase AC excited nonequilibrium atmospheric pressure Ar plasma"}]},{"@id":"https://cir.nii.ac.jp/crid/2051151842066372480","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@value":"Effects of plasma-activated Ringer’s lactate solution on cancer cells : evaluation of genotoxicity"}]}],"dataSourceIdentifier":[{"@type":"CROSSREF","@value":"10.1002/bem.20005"},{"@type":"CROSSREF","@value":"10.1111/jcmm.12880_references_DOI_ZU3zUH85CF6anUhZOm6hZRq7O2d"},{"@type":"CROSSREF","@value":"10.1143/jjap.47.3625_references_DOI_ZU3zUH85CF6anUhZOm6hZRq7O2d"},{"@type":"CROSSREF","@value":"10.3390/plasma1010014_references_DOI_ZU3zUH85CF6anUhZOm6hZRq7O2d"},{"@type":"CROSSREF","@value":"10.7567/apex.7.026202_references_DOI_ZU3zUH85CF6anUhZOm6hZRq7O2d"},{"@type":"CROSSREF","@value":"10.1080/10715762.2023.2193308_references_DOI_ZU3zUH85CF6anUhZOm6hZRq7O2d"},{"@type":"CROSSREF","@value":"10.1038/s41598-023-42976-4_references_DOI_ZU3zUH85CF6anUhZOm6hZRq7O2d"},{"@type":"CROSSREF","@value":"10.1038/s41598-017-11877-8_references_DOI_ZU3zUH85CF6anUhZOm6hZRq7O2d"},{"@type":"CROSSREF","@value":"10.1116/1.4921278_references_DOI_ZU3zUH85CF6anUhZOm6hZRq7O2d"},{"@type":"CROSSREF","@value":"10.1515/hsz-2018-0199_references_DOI_ZU3zUH85CF6anUhZOm6hZRq7O2d"},{"@type":"CROSSREF","@value":"10.1109/tps.2014.2353659_references_DOI_ZU3zUH85CF6anUhZOm6hZRq7O2d"},{"@type":"CROSSREF","@value":"10.1007/s41614-017-0004-3_references_DOI_ZU3zUH85CF6anUhZOm6hZRq7O2d"},{"@type":"CROSSREF","@value":"10.1245/s10434-017-6239-y_references_DOI_ZU3zUH85CF6anUhZOm6hZRq7O2d"},{"@type":"CROSSREF","@value":"10.1245/s10434-016-5759-1_references_DOI_ZU3zUH85CF6anUhZOm6hZRq7O2d"},{"@type":"CROSSREF","@value":"10.1002/ppap.202100056_references_DOI_ZU3zUH85CF6anUhZOm6hZRq7O2d"},{"@type":"CROSSREF","@value":"10.1186/s41021-023-00260-x_references_DOI_ZU3zUH85CF6anUhZOm6hZRq7O2d"},{"@type":"CROSSREF","@value":"10.1016/j.cpme.2015.09.001_references_DOI_ZU3zUH85CF6anUhZOm6hZRq7O2d"},{"@type":"CROSSREF","@value":"10.3164/jcbn.16-65_references_DOI_ZU3zUH85CF6anUhZOm6hZRq7O2d"}]}