{"@context":{"@vocab":"https://cir.nii.ac.jp/schema/1.0/","rdfs":"http://www.w3.org/2000/01/rdf-schema#","dc":"http://purl.org/dc/elements/1.1/","dcterms":"http://purl.org/dc/terms/","foaf":"http://xmlns.com/foaf/0.1/","prism":"http://prismstandard.org/namespaces/basic/2.0/","cinii":"http://ci.nii.ac.jp/ns/1.0/","datacite":"https://schema.datacite.org/meta/kernel-4/","ndl":"http://ndl.go.jp/dcndl/terms/","jpcoar":"https://github.com/JPCOAR/schema/blob/master/2.0/"},"@id":"https://cir.nii.ac.jp/crid/1361981470141609600.json","@type":"Article","productIdentifier":[{"identifier":{"@type":"DOI","@value":"10.1107/s0909049506006972"}},{"identifier":{"@type":"URI","@value":"http://journals.iucr.org/s/issues/2006/03/00/fh5365/fh5365.pdf"}},{"identifier":{"@type":"PMID","@value":"16645253"}}],"dc:title":[{"@value":"X-ray diffractometer combining synchrotron radiation and pulsed magnetic fields up to 40 T"}],"description":[{"notation":[{"@value":"A synchrotron X-ray diffractometer incorporating a pulsed field magnet for high fields up to 40 T has been developed and a detailed description of this instrument is reported. The pulsed field magnet is composed of two coaxial coils with a gap of 3 mm at the mid-plane for passage of the X-rays. The pixel detector PILATUS 100K is used to store the diffracted X-rays. As a test of this instrument, X-ray diffraction by a powder sample of the antiferromagnet CoO is measured below the Néel temperature. A field-dependent lattice distortion of CoO due to magnetostriction is observed up to 38 T."}]}],"creator":[{"@id":"https://cir.nii.ac.jp/crid/1380004240551534602","@type":"Researcher","foaf:name":[{"@value":"Y. Narumi"}]},{"@id":"https://cir.nii.ac.jp/crid/1381981470141609601","@type":"Researcher","foaf:name":[{"@value":"K. Kindo"}]},{"@id":"https://cir.nii.ac.jp/crid/1381981470141609600","@type":"Researcher","foaf:name":[{"@value":"K. Katsumata"}]},{"@id":"https://cir.nii.ac.jp/crid/1381981470141609608","@type":"Researcher","foaf:name":[{"@value":"M. Kawauchi"}]},{"@id":"https://cir.nii.ac.jp/crid/1381981470141609472","@type":"Researcher","foaf:name":[{"@value":"Ch. Broennimann"}]},{"@id":"https://cir.nii.ac.jp/crid/1381981470141609609","@type":"Researcher","foaf:name":[{"@value":"U. Staub"}]},{"@id":"https://cir.nii.ac.jp/crid/1381981470141609606","@type":"Researcher","foaf:name":[{"@value":"H. Toyokawa"}]},{"@id":"https://cir.nii.ac.jp/crid/1381981470141609610","@type":"Researcher","foaf:name":[{"@value":"Y. Tanaka"}]},{"@id":"https://cir.nii.ac.jp/crid/1381981470141609605","@type":"Researcher","foaf:name":[{"@value":"A. Kikkawa"}]},{"@id":"https://cir.nii.ac.jp/crid/1381981470141609604","@type":"Researcher","foaf:name":[{"@value":"T. Yamamoto"}]},{"@id":"https://cir.nii.ac.jp/crid/1381981470141609611","@type":"Researcher","foaf:name":[{"@value":"M. Hagiwara"}]},{"@id":"https://cir.nii.ac.jp/crid/1381981470141609607","@type":"Researcher","foaf:name":[{"@value":"T. Ishikawa"}]},{"@id":"https://cir.nii.ac.jp/crid/1381981470141609602","@type":"Researcher","foaf:name":[{"@value":"H. Kitamura"}]}],"publication":{"publicationIdentifier":[{"@type":"PISSN","@value":"09090495"}],"prism:publicationName":[{"@value":"Journal of Synchrotron Radiation"}],"dc:publisher":[{"@value":"International Union of Crystallography (IUCr)"}],"prism:publicationDate":"2006-04-13","prism:volume":"13","prism:number":"3","prism:startingPage":"271","prism:endingPage":"274"},"reviewed":"false","dcterms:accessRights":"http://purl.org/coar/access_right/c_abf2","dc:rights":["http://journals.iucr.org/services/copyrightpolicy.html","http://journals.iucr.org/services/copyrightpolicy.html#TDM"],"url":[{"@id":"http://journals.iucr.org/s/issues/2006/03/00/fh5365/fh5365.pdf"}],"createdAt":"2006-04-27","modifiedAt":"2025-01-11","relatedProduct":[{"@id":"https://cir.nii.ac.jp/crid/1360003446870225280","@type":"Article","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@value":"Field Induced Lattice Deformation in a Quasi-One-Dimensional Antiferromagnet BaCo<sub>2</sub>V<sub>2</sub>O<sub>8</sub>"}]},{"@id":"https://cir.nii.ac.jp/crid/1360009142623681920","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@value":"Single shot x-ray diffractometry in SACLA with pulsed magnetic fields up to 16 T"}]},{"@id":"https://cir.nii.ac.jp/crid/1360285709145418752","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@value":"Precision X-ray Diffraction Studies in High Pulsed Magnetic Fields at the Advanced Photon Source"}]},{"@id":"https://cir.nii.ac.jp/crid/1360285710023811712","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@value":"Search for Two-Photon Interaction with Axionlike Particles Using High-Repetition Pulsed Magnets and Synchrotron X Rays"}]},{"@id":"https://cir.nii.ac.jp/crid/1360566399834256896","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@value":"Recent Progress of the X-ray Magnetic Circular Dichroism Technique for Element-Specific Magnetic Analysis"}]},{"@id":"https://cir.nii.ac.jp/crid/1360566399834257920","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@value":"X-ray Diffraction and Absorption Spectroscopy in Pulsed High Magnetic Fields"}]},{"@id":"https://cir.nii.ac.jp/crid/1360567183851681152","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@value":"A single-solenoid pulsed-magnet system for single-crystal scattering studies"}]},{"@id":"https://cir.nii.ac.jp/crid/1360567184122129408","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@value":"X-ray Spectroscopies in Pulsed High Magnetic Fields: New Frontier with Flying Magnets and Rolling Capacitor Banks"}]},{"@id":"https://cir.nii.ac.jp/crid/1360848658827907840","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@value":"Time-resolved one-dimensional detection of x-ray scattering in pulsed magnetic fields"}]},{"@id":"https://cir.nii.ac.jp/crid/1390001204194052608","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@language":"en","@value":"Lattice Deformations Induced by an Applied Magnetic Field in the Frustrated Antiferromagnet HgCr<SUB>2</SUB>O<SUB>4</SUB>"},{"@value":"Lattice deformations induced by an applied magnetic field in the frustrated antiferromagnet HgCr2O4"}]},{"@id":"https://cir.nii.ac.jp/crid/1390001204197847808","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@language":"en","@value":"Magnetization Process and the Associated Lattice Deformations in an Intermetallic Compound Gd<SUB>5</SUB>Ge<SUB>3</SUB>"},{"@value":"Magnetization process and the associated lattice deformations in an intermetallic compound Gd5Ge3"}]},{"@id":"https://cir.nii.ac.jp/crid/1390001204255305344","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@language":"en","@value":"The Effect of Local Structural Disruption on the Yield of Photochemical Ligation between Anthracene-Oligonucleotide Conjugates"}]},{"@id":"https://cir.nii.ac.jp/crid/1390282679166214400","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@language":"en","@value":"Lattice Distortion in Antiferromagnetic CoO under High Magnetic Fields"}]},{"@id":"https://cir.nii.ac.jp/crid/1390282679172974720","@type":"Article","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@language":"en","@value":"Field Induced Lattice Deformation in the Quantum Antiferromagnet SrCu<SUB>2</SUB>(BO<SUB>3</SUB>)<SUB>2</SUB>"},{"@value":"Field induced lattice deformation in the quantum antiferromagnet SrCu2(BO3)2"}]},{"@id":"https://cir.nii.ac.jp/crid/1390282679232010112","@type":"Article","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@language":"en","@value":"Synchrotron X-ray Experiments in Pulsed High Magnetic Fields"}]},{"@id":"https://cir.nii.ac.jp/crid/1520293865796073216","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@value":"State-of-the-Art Pulsed-High-Magnetic-Field Magnetometries Based on X-ray Magnetic Circular Dichroism and Proximity Detector Oscillator"}]}],"dataSourceIdentifier":[{"@type":"CROSSREF","@value":"10.1107/s0909049506006972"},{"@type":"OPENAIRE","@value":"doi_dedup___::a274c88aa67c87c6cad0a5f336193549"},{"@type":"CROSSREF","@value":"10.7566/jpsj.82.021006_references_DOI_LIYFjRDQkK7zlLIUBsde1NPY0vD"},{"@type":"CROSSREF","@value":"10.1143/jpsj.75.075001_references_DOI_LIYFjRDQkK7zlLIUBsde1NPY0vD"},{"@type":"CROSSREF","@value":"10.1143/jpsj.79.043706_references_DOI_LIYFjRDQkK7zlLIUBsde1NPY0vD"},{"@type":"CROSSREF","@value":"10.1103/physrevresearch.2.043175_references_DOI_LIYFjRDQkK7zlLIUBsde1NPY0vD"},{"@type":"CROSSREF","@value":"10.2116/analsci.24.173_references_DOI_LIYFjRDQkK7zlLIUBsde1NPY0vD"},{"@type":"CROSSREF","@value":"10.1080/08940886.2012.736830_references_DOI_LIYFjRDQkK7zlLIUBsde1NPY0vD"},{"@type":"CROSSREF","@value":"10.1103/physrevlett.118.071803_references_DOI_LIYFjRDQkK7zlLIUBsde1NPY0vD"},{"@type":"CROSSREF","@value":"10.7566/jpsj.82.021009_references_DOI_LIYFjRDQkK7zlLIUBsde1NPY0vD"},{"@type":"CROSSREF","@value":"10.1063/1.3688251_references_DOI_LIYFjRDQkK7zlLIUBsde1NPY0vD"},{"@type":"CROSSREF","@value":"10.1080/08940886.2012.736833_references_DOI_LIYFjRDQkK7zlLIUBsde1NPY0vD"},{"@type":"CROSSREF","@value":"10.1143/jpsj.77.053711_references_DOI_LIYFjRDQkK7zlLIUBsde1NPY0vD"},{"@type":"CROSSREF","@value":"10.7566/jpsj.91.101007_references_DOI_LIYFjRDQkK7zlLIUBsde1NPY0vD"},{"@type":"CROSSREF","@value":"10.1063/1.3675478_references_DOI_LIYFjRDQkK7zlLIUBsde1NPY0vD"},{"@type":"CROSSREF","@value":"10.1143/jpsj.76.043708_references_DOI_LIYFjRDQkK7zlLIUBsde1NPY0vD"},{"@type":"CROSSREF","@value":"10.1143/jpsj.78.043702_references_DOI_LIYFjRDQkK7zlLIUBsde1NPY0vD"},{"@type":"CROSSREF","@value":"10.2116/analsci.24.3_references_DOI_LIYFjRDQkK7zlLIUBsde1NPY0vD"}]}