{"@context":{"@vocab":"https://cir.nii.ac.jp/schema/1.0/","rdfs":"http://www.w3.org/2000/01/rdf-schema#","dc":"http://purl.org/dc/elements/1.1/","dcterms":"http://purl.org/dc/terms/","foaf":"http://xmlns.com/foaf/0.1/","prism":"http://prismstandard.org/namespaces/basic/2.0/","cinii":"http://ci.nii.ac.jp/ns/1.0/","datacite":"https://schema.datacite.org/meta/kernel-4/","ndl":"http://ndl.go.jp/dcndl/terms/","jpcoar":"https://github.com/JPCOAR/schema/blob/master/2.0/"},"@id":"https://cir.nii.ac.jp/crid/1362262946090342016.json","@type":"Article","productIdentifier":[{"identifier":{"@type":"DOI","@value":"10.1067/mhn.2002.122182"}},{"identifier":{"@type":"URI","@value":"http://api.elsevier.com/content/article/PII:S0194-5998(02)32101-6?httpAccept=text/xml"}},{"identifier":{"@type":"URI","@value":"https://onlinelibrary.wiley.com/doi/pdf/10.1067/mhn.2002.122182"}},{"identifier":{"@type":"URI","@value":"http://api.elsevier.com/content/article/PII:S0194-5998(02)32101-6?httpAccept=text/plain"}},{"identifier":{"@type":"URI","@value":"https://aao-hnsfjournals.onlinelibrary.wiley.com/doi/pdf/10.1067/mhn.2002.122182"}}],"dc:title":[{"@value":"Phase III Clinical Trial Results with the Vibrant Soundbridge Implantable Middle Ear Hearing Device: A Prospective Controlled Multicenter Study"}],"description":[{"type":"abstract","notation":[{"@value":"<jats:sec><jats:title>OBJECTIVES</jats:title><jats:p>The goal of the study was to evaluate the performance of a semi‐implantable middle ear hearing device (Vibrant Soundbridge System [VSB]; Symphonix Devices, Inc).</jats:p></jats:sec><jats:sec><jats:title>STUDY DESIGN</jats:title><jats:p>A prospective, single‐subject, repeated‐measures multicenter study was conducted to determine the safety and efficacy of the VSB using analog and digital external processors. Measures included residual hearing, functional gain, speech recognition, acoustic feedback, occlusion, and patient self‐assessment to determine satisfaction, perceived performance, and device preference compared with an appropriately fit acoustic hearing aid. Fifty‐three adult subjects with moderate to severe sensorineural hearing loss were evaluated at 4 or more intervals after implantation.</jats:p></jats:sec><jats:sec><jats:title>RESULTS</jats:title><jats:p>Improvements in satisfaction, performance, and preference were statistically significant with the VSB, as was functional gain across all test frequencies (<jats:italic>P</jats:italic> < 0.001). Occlusion and feedback were virtually eliminated. Aided speech recognition was comparable between VSB and the hearing aid. Residual hearing was unchanged.</jats:p></jats:sec><jats:sec><jats:title>CONCLUSION</jats:title><jats:p>The VSB is a safe and effective treatment option for adults with moderate to severe sensorineural hearing loss.</jats:p></jats:sec>"}]}],"creator":[{"@id":"https://cir.nii.ac.jp/crid/1382262946090342022","@type":"Researcher","foaf:name":[{"@value":"Charles M. Luetje"}],"jpcoar:affiliationName":[{"@value":"Otologic Center, Inc Kansas City Missouri"}]},{"@id":"https://cir.nii.ac.jp/crid/1382262946090342024","@type":"Researcher","foaf:name":[{"@value":"Derald Brackman"}],"jpcoar:affiliationName":[{"@value":"House Ear Institute Los Angeles California"}]},{"@id":"https://cir.nii.ac.jp/crid/1382262946090342023","@type":"Researcher","foaf:name":[{"@value":"Thomas J. Balkany"}],"jpcoar:affiliationName":[{"@value":"University of Miami School of Medicine Miami Florida"}]},{"@id":"https://cir.nii.ac.jp/crid/1382262946090342018","@type":"Researcher","foaf:name":[{"@value":"Jennifer Maw"}],"jpcoar:affiliationName":[{"@value":"Hearing Institute for Children and Adults San Jose California"}]},{"@id":"https://cir.nii.ac.jp/crid/1382262946090342017","@type":"Researcher","foaf:name":[{"@value":"R. Stanley Baker"}],"jpcoar:affiliationName":[{"@value":"Otologic Medical Center, Inc Oklahoma City Oklahoma"}]},{"@id":"https://cir.nii.ac.jp/crid/1382262946090342021","@type":"Researcher","foaf:name":[{"@value":"David Kelsall"}],"jpcoar:affiliationName":[{"@value":"Denver Ear Associates Englewood Colorado"}]},{"@id":"https://cir.nii.ac.jp/crid/1382262946090342016","@type":"Researcher","foaf:name":[{"@value":"Douglas Backous"}],"jpcoar:affiliationName":[{"@value":"Virginia Mason Clinic Seattle Washington"}]},{"@id":"https://cir.nii.ac.jp/crid/1382262946090342019","@type":"Researcher","foaf:name":[{"@value":"Richard Miyamoto"}],"jpcoar:affiliationName":[{"@value":"Indiana University School of Medicine Indianapolis Indiana"}]},{"@id":"https://cir.nii.ac.jp/crid/1382262946090342020","@type":"Researcher","foaf:name":[{"@value":"Simon Parisier"}],"jpcoar:affiliationName":[{"@value":"Lenox Hill Hospital New York New York"}]},{"@id":"https://cir.nii.ac.jp/crid/1382262946090342025","@type":"Researcher","foaf:name":[{"@value":"Alexander Arts"}],"jpcoar:affiliationName":[{"@value":"University of Michigan Medical Center Ann Arbor Michigan"}]}],"publication":{"publicationIdentifier":[{"@type":"PISSN","@value":"01945998"},{"@type":"EISSN","@value":"10976817"}],"prism:publicationName":[{"@value":"Otolaryngology–Head and Neck Surgery"}],"dc:publisher":[{"@value":"Wiley"}],"prism:publicationDate":"2002-02","prism:volume":"126","prism:number":"2","prism:startingPage":"97","prism:endingPage":"107"},"reviewed":"false","dc:rights":["http://onlinelibrary.wiley.com/termsAndConditions#vor"],"url":[{"@id":"http://api.elsevier.com/content/article/PII:S0194-5998(02)32101-6?httpAccept=text/xml"},{"@id":"https://onlinelibrary.wiley.com/doi/pdf/10.1067/mhn.2002.122182"},{"@id":"http://api.elsevier.com/content/article/PII:S0194-5998(02)32101-6?httpAccept=text/plain"},{"@id":"https://aao-hnsfjournals.onlinelibrary.wiley.com/doi/pdf/10.1067/mhn.2002.122182"}],"createdAt":"2003-02-04","modifiedAt":"2025-10-20","relatedProduct":[{"@id":"https://cir.nii.ac.jp/crid/1050287297263837312","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@value":"Round Window Application of an Active Middle Ear Implant: A Comparison With Hearing Aid Usage in Japan"}]},{"@id":"https://cir.nii.ac.jp/crid/1390001204327321984","@type":"Article","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@language":"en","@value":"A Case of Middle Ear Implant VSB (Vibrant Soundbridge<sup>®</sup>)"},{"@language":"ja","@value":"人工中耳Vibrant Soundbridge<sup>®</sup>国内臨床治験例"},{"@value":"人工中耳Vibrant Soundbridge国内臨床治験例"},{"@language":"ja-Kana","@value":"ジンコウ チュウジ Vibrant Soundbridge コクナイ リンショウチケンレイ"}]},{"@id":"https://cir.nii.ac.jp/crid/1390001205012217088","@type":"Article","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@language":"ja","@value":"最近の人工聴覚機器"},{"@value":"第115回日本耳鼻咽喉科学会総会ランチョンセミナー 最近の人工聴覚機器"},{"@language":"ja-Kana","@value":"ダイ115カイ ニホン ジビ インコウ カガクカイ ソウカイ ランチョンセミナー サイキン ノ ジンコウ チョウカク キキ"}]},{"@id":"https://cir.nii.ac.jp/crid/1390287595704614912","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@language":"ja","@value":"伝音・混合性難聴に対する人工中耳と能動型骨導インプラントの現状と将来"},{"@value":"伝音・混合性難聴に対する人工中耳と能動型骨導インプラントの現状と将来 : 第121回日本耳鼻咽喉科学会総会ランチョンセミナー"},{"@language":"ja-Kana","@value":"デンオン ・ コンゴウセイ ナンチョウ ニ タイスル ジンコウ チュウジ ト ノウドウガタ コツドウ インプラント ノ ゲンジョウ ト ショウライ : ダイ121カイ ニホン ジビ インコウ カガクカイ ソウカイ ランチョンセミナー"}]}],"dataSourceIdentifier":[{"@type":"CROSSREF","@value":"10.1067/mhn.2002.122182"},{"@type":"CROSSREF","@value":"10.3950/jibiinkoka.124.176_references_DOI_VwyiTB9Igj9lyllluaVISxc2xx2"},{"@type":"CROSSREF","@value":"10.5631/jibirinsuppl.147.16_references_DOI_VwyiTB9Igj9lyllluaVISxc2xx2"},{"@type":"CROSSREF","@value":"10.1097/mao.0000000000001438_references_DOI_VwyiTB9Igj9lyllluaVISxc2xx2"},{"@type":"CROSSREF","@value":"10.3950/jibiinkoka.118.636_references_DOI_VwyiTB9Igj9lyllluaVISxc2xx2"}]}