{"@context":{"@vocab":"https://cir.nii.ac.jp/schema/1.0/","rdfs":"http://www.w3.org/2000/01/rdf-schema#","dc":"http://purl.org/dc/elements/1.1/","dcterms":"http://purl.org/dc/terms/","foaf":"http://xmlns.com/foaf/0.1/","prism":"http://prismstandard.org/namespaces/basic/2.0/","cinii":"http://ci.nii.ac.jp/ns/1.0/","datacite":"https://schema.datacite.org/meta/kernel-4/","ndl":"http://ndl.go.jp/dcndl/terms/","jpcoar":"https://github.com/JPCOAR/schema/blob/master/2.0/"},"@id":"https://cir.nii.ac.jp/crid/1362825894119505664.json","@type":"Article","productIdentifier":[{"identifier":{"@type":"DOI","@value":"10.1117/1.3400665"}},{"identifier":{"@type":"URI","@value":"http://biomedicaloptics.spiedigitallibrary.org/article.aspx?articleid=1103358"}}],"dc:title":[{"@value":"Multispectral in vivo three-dimensional optical coherence tomography of human skin"}],"creator":[{"@id":"https://cir.nii.ac.jp/crid/1382825894119505669","@type":"Researcher","foaf:name":[{"@value":"Aneesh Alex"}]},{"@id":"https://cir.nii.ac.jp/crid/1382825894119505665","@type":"Researcher","foaf:name":[{"@value":"Boris Považay"}]},{"@id":"https://cir.nii.ac.jp/crid/1382825894119505667","@type":"Researcher","foaf:name":[{"@value":"Bernd Hofer"}]},{"@id":"https://cir.nii.ac.jp/crid/1382825894119505664","@type":"Researcher","foaf:name":[{"@value":"Sergei Popov"}]},{"@id":"https://cir.nii.ac.jp/crid/1382825894119505670","@type":"Researcher","foaf:name":[{"@value":"Carl Glittenberg"}]},{"@id":"https://cir.nii.ac.jp/crid/1382825894119505668","@type":"Researcher","foaf:name":[{"@value":"Susanne Binder"}]},{"@id":"https://cir.nii.ac.jp/crid/1382825894119505666","@type":"Researcher","foaf:name":[{"@value":"Wolfgang Drexler"}]}],"publication":{"publicationIdentifier":[{"@type":"PISSN","@value":"10833668"}],"prism:publicationName":[{"@value":"Journal of Biomedical Optics"}],"dc:publisher":[{"@value":"SPIE-Intl Soc Optical Eng"}],"prism:publicationDate":"2010","prism:volume":"15","prism:number":"2","prism:startingPage":"026025"},"reviewed":"false","url":[{"@id":"http://biomedicaloptics.spiedigitallibrary.org/article.aspx?articleid=1103358"}],"createdAt":"2010-05-04","modifiedAt":"2019-02-28","relatedProduct":[{"@id":"https://cir.nii.ac.jp/crid/1360285710850000640","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@value":"Axial resolution and signal-to-noise ratio in deep-tissue imaging with 1.7    -  μ  m     high-resolution optical coherence tomography with an ultrabroadband laser source"}]}],"dataSourceIdentifier":[{"@type":"CROSSREF","@value":"10.1117/1.3400665"},{"@type":"CROSSREF","@value":"10.1117/1.jbo.22.8.085002_references_DOI_QIgrsGU7IjjVx4oP13tb59ELb64"}]}