{"@context":{"@vocab":"https://cir.nii.ac.jp/schema/1.0/","rdfs":"http://www.w3.org/2000/01/rdf-schema#","dc":"http://purl.org/dc/elements/1.1/","dcterms":"http://purl.org/dc/terms/","foaf":"http://xmlns.com/foaf/0.1/","prism":"http://prismstandard.org/namespaces/basic/2.0/","cinii":"http://ci.nii.ac.jp/ns/1.0/","datacite":"https://schema.datacite.org/meta/kernel-4/","ndl":"http://ndl.go.jp/dcndl/terms/","jpcoar":"https://github.com/JPCOAR/schema/blob/master/2.0/"},"@id":"https://cir.nii.ac.jp/crid/1363388843559413120.json","@type":"Article","productIdentifier":[{"identifier":{"@type":"DOI","@value":"10.1029/95ja01755"}},{"identifier":{"@type":"URI","@value":"https://api.wiley.com/onlinelibrary/tdm/v1/articles/10.1029%2F95JA01755"}},{"identifier":{"@type":"URI","@value":"https://agupubs.onlinelibrary.wiley.com/doi/pdf/10.1029/95JA01755"}}],"dc:title":[{"@value":"Models of high‐latitude electric potentials derived with a least error fit of spherical harmonic coefficients"}],"description":[{"type":"abstract","notation":[{"@value":"<jats:p>New models of the high‐latitude electric potentials have been developed. These models show how the polar ionospheric electric field, or plasma convection, responds to changes in the interplanetary magnetic field (IMF) and other parameters, such as dipole tilt angle. These patterns were derived from measurements of the electric field on the DE 2 satellite, using all polar cap passes during which high‐resolution IMF data were available from the ISEE 3 or IMP 8 satellites. The data are sorted according to the angle of the IMF in the GSM <jats:italic>Y‐Z</jats:italic> plane. The measurements are further divided into different groups according to the magnitude of the IMF or the dipole tilt angle. All measurements in each group are then used to derive a model of the electric potential for the given conditions, using a new technique where the coefficients of a spherical harmonic expansion are found by least square error fits. The resulting convection patterns are very realistic and show consistent variations as the IMF <jats:italic>B<jats:sub>Y</jats:sub></jats:italic>/<jats:italic>B<jats:sub>Z</jats:sub></jats:italic> angle rotates. For northward IMF (positive <jats:italic>B<jats:sub>Z</jats:sub></jats:italic>) evidently there are four convection “cells,” rather than a distortion of the two‐cell pattern. Many other useful facts regarding the solar wind‐ionosphere coupling can be extracted from the derived patterns, such as the relationship between the polar cap potential drop and the IMF clock angle.</jats:p>"}]}],"creator":[{"@id":"https://cir.nii.ac.jp/crid/1380584340723921424","@type":"Researcher","foaf:name":[{"@value":"D. R. Weimer"}]}],"publication":{"publicationIdentifier":[{"@type":"PISSN","@value":"01480227"}],"prism:publicationName":[{"@value":"Journal of Geophysical Research: Space Physics"}],"dc:publisher":[{"@value":"American Geophysical Union (AGU)"}],"prism:publicationDate":"1995-10","prism:volume":"100","prism:number":"A10","prism:startingPage":"19595","prism:endingPage":"19607"},"reviewed":"false","dc:rights":["http://onlinelibrary.wiley.com/termsAndConditions#vor"],"url":[{"@id":"https://api.wiley.com/onlinelibrary/tdm/v1/articles/10.1029%2F95JA01755"},{"@id":"https://agupubs.onlinelibrary.wiley.com/doi/pdf/10.1029/95JA01755"}],"createdAt":"2004-02-03","modifiedAt":"2023-09-22","relatedProduct":[{"@id":"https://cir.nii.ac.jp/crid/1050282810809477632","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@language":"en","@value":"IMF-By dependence of transient ionospheric flow perturbation associated with sudden impulses: SuperDARN observations"}]},{"@id":"https://cir.nii.ac.jp/crid/1360004229808121344","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@value":"Average field‐aligned ion velocity over the EISCAT radars"}]},{"@id":"https://cir.nii.ac.jp/crid/1360017279829990144","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@value":"Auroral Heating of Plasma Patches Due to High‐Latitude Reconnection"}]},{"@id":"https://cir.nii.ac.jp/crid/1360021390743232256","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@value":"Evaluation of the Empirical Scaling Factor of Joule Heating Rates in TIE‐GCM With EISCAT Measurements"}]},{"@id":"https://cir.nii.ac.jp/crid/1360285704779054336","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@value":"A 2‐D empirical plasma sheet pressure model for substorm growth phase using the Support Vector Regression Machine"}]},{"@id":"https://cir.nii.ac.jp/crid/1360567183238366976","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@value":"Motion of polar cap patches: A statistical study with all‐sky airglow imager at Resolute Bay, Canada"}]},{"@id":"https://cir.nii.ac.jp/crid/1360580229797360384","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@value":"Unexpected space weather causing the reentry of 38 Starlink satellites in February 2022"}]},{"@id":"https://cir.nii.ac.jp/crid/1360584340723921408","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@value":"Machine learning emulator for physics-based prediction of ionospheric potential response to solar wind variations"}]},{"@id":"https://cir.nii.ac.jp/crid/1360588380132190592","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@value":"Dayside Magnetic Depression Following Interplanetary Shock Arrivals During the February 1958 and July 1959 Superstorms"}]},{"@id":"https://cir.nii.ac.jp/crid/1361131418079563904","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@value":"First Observation of Ionospheric Convection From the Jiamusi HF Radar During a Strong Geomagnetic Storm"}]},{"@id":"https://cir.nii.ac.jp/crid/1361412893056781184","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@value":"Three‐Dimensional Fourier Analysis of the Phase Velocity Distributions of Mesospheric and Ionospheric Waves Based on Airglow Images Collected Over 10 Years: Comparison of Magadan, Russia, and Athabasca, Canada"}]},{"@id":"https://cir.nii.ac.jp/crid/1361694368031988352","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@value":"Deformation of Ionospheric Potential Pattern by Ionospheric Hall Polarization"}]},{"@id":"https://cir.nii.ac.jp/crid/1361975843010174080","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@value":"Mesoscale Convection Structures Associated With Airglow Patches Characterized Using Cluster‐Imager Conjunctions"}]},{"@id":"https://cir.nii.ac.jp/crid/2051714791998691712","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@value":"Thermospheric wind variations observed by a Fabry–Perot interferometer at Tromsø, Norway, at substorm onsets"}]},{"@id":"https://cir.nii.ac.jp/crid/2051996266977815552","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@value":"High-latitude thermospheric wind study using a Fabry–Perot interferometer at Tromso in Norway : averages and variations during quiet times"}]}],"dataSourceIdentifier":[{"@type":"CROSSREF","@value":"10.1029/95ja01755"},{"@type":"CROSSREF","@value":"10.1002/2017ja023974_references_DOI_VtAK2EWC8N2jZ8i6hu2tGuUAlzT"},{"@type":"CROSSREF","@value":"10.1029/2021ja029657_references_DOI_VBKCCVkvN1J0BzHLsdi4eE72IOS"},{"@type":"CROSSREF","@value":"10.1029/2023ea003447_references_DOI_VtAK2EWC8N2jZ8i6hu2tGuUAlzT"},{"@type":"CROSSREF","@value":"10.1002/2014ja020787_references_DOI_VtAK2EWC8N2jZ8i6hu2tGuUAlzT"},{"@type":"CROSSREF","@value":"10.1029/2008ja014020_references_DOI_VtAK2EWC8N2jZ8i6hu2tGuUAlzT"},{"@type":"CROSSREF","@value":"10.1051/swsc/2022034_references_DOI_VtAK2EWC8N2jZ8i6hu2tGuUAlzT"},{"@type":"CROSSREF","@value":"10.1186/s40623-023-01896-3_references_DOI_VtAK2EWC8N2jZ8i6hu2tGuUAlzT"},{"@type":"CROSSREF","@value":"10.1029/2024sw004017_references_DOI_VtAK2EWC8N2jZ8i6hu2tGuUAlzT"},{"@type":"CROSSREF","@value":"10.1186/s40623-015-0360-6_references_DOI_VtAK2EWC8N2jZ8i6hu2tGuUAlzT"},{"@type":"CROSSREF","@value":"10.1186/s40623-019-1072-0_references_DOI_VtAK2EWC8N2jZ8i6hu2tGuUAlzT"},{"@type":"CROSSREF","@value":"10.1029/2019ea000911_references_DOI_VtAK2EWC8N2jZ8i6hu2tGuUAlzT"},{"@type":"CROSSREF","@value":"10.1029/2019ja026783_references_DOI_VtAK2EWC8N2jZ8i6hu2tGuUAlzT"},{"@type":"CROSSREF","@value":"10.1186/s40623-019-1093-8_references_DOI_VtAK2EWC8N2jZ8i6hu2tGuUAlzT"},{"@type":"CROSSREF","@value":"10.1029/2018ja026013_references_DOI_VtAK2EWC8N2jZ8i6hu2tGuUAlzT"},{"@type":"CROSSREF","@value":"10.1029/2019ja026611_references_DOI_VtAK2EWC8N2jZ8i6hu2tGuUAlzT"}]}