Combinatorial microelectrochemistry: Development and evaluation of an electrochemical robotic system

  • Thomas Erichsen
    Ruhr-Universität Bochum Anal. Chem.—Elektroanalytik & Sensorik, , Universitätsstrasse 150, D-44780 Bochum, Germany
  • Sabine Reiter
    Ruhr-Universität Bochum Anal. Chem.—Elektroanalytik & Sensorik, , Universitätsstrasse 150, D-44780 Bochum, Germany
  • Victoria Ryabova
    Ruhr-Universität Bochum Anal. Chem.—Elektroanalytik & Sensorik, , Universitätsstrasse 150, D-44780 Bochum, Germany
  • Eva Maria Bonsen
    Ruhr-Universität Bochum Anal. Chem.—Elektroanalytik & Sensorik, , Universitätsstrasse 150, D-44780 Bochum, Germany
  • Wolfgang Schuhmann
    Ruhr-Universität Bochum Anal. Chem.—Elektroanalytik & Sensorik, , Universitätsstrasse 150, D-44780 Bochum, Germany
  • Wolfgang Märkle
    Universität Tübingen Institut für Organische Chemie, , Auf der Morgenstelle 18, D-72076 Tübingen, Germany
  • Carsten Tittel
    Universität Tübingen Institut für Organische Chemie, , Auf der Morgenstelle 18, D-72076 Tübingen, Germany
  • Günther Jung
    Universität Tübingen Institut für Organische Chemie, , Auf der Morgenstelle 18, D-72076 Tübingen, Germany
  • Bernd Speiser
    Universität Tübingen Institut für Organische Chemie, , Auf der Morgenstelle 18, D-72076 Tübingen, Germany

書誌事項

公開日
2005-05-17
DOI
  • 10.1063/1.1906106
公開者
AIP Publishing

この論文をさがす

説明

<jats:p>An electrochemical robotic system using standard microtiter plates as reaction wells for potentiostatic and galvanostatic electrosynthesis and high-throughput electroanalysis was conceived and realized using stepmotor driven positioning stages in combination with a flexible software. Electrode bundles specifically adapted to the experimental needs are accurately positioned in the wells of a microtiter plate followed by the automatic performance of sequences of electrosynthetic or electroanalytical techniques. The system allows us to work under inert-gas atmosphere, in aqueous and organic solvents, and to add or remove solutions by means of integrated syringe pumps. A specifically developed script language permits the user to perform very complex experimental sequences in the different wells of the microtiter plate. The hardware and software features of the developed electrochemical robotic system, the design of suitable electrode arrangements for electrosynthesis and electroanalytical techniques, as well as the reproducibility in aqueous and organic electrolytes are described. The performance of the system is demonstrated by redox screening of a Ru-complex library and by electrosynthesis with in situ analysis of a compound library.</jats:p>

収録刊行物

被引用文献 (2)*注記

もっと見る

詳細情報 詳細情報について

問題の指摘

ページトップへ