{"@context":{"@vocab":"https://cir.nii.ac.jp/schema/1.0/","rdfs":"http://www.w3.org/2000/01/rdf-schema#","dc":"http://purl.org/dc/elements/1.1/","dcterms":"http://purl.org/dc/terms/","foaf":"http://xmlns.com/foaf/0.1/","prism":"http://prismstandard.org/namespaces/basic/2.0/","cinii":"http://ci.nii.ac.jp/ns/1.0/","datacite":"https://schema.datacite.org/meta/kernel-4/","ndl":"http://ndl.go.jp/dcndl/terms/","jpcoar":"https://github.com/JPCOAR/schema/blob/master/2.0/"},"@id":"https://cir.nii.ac.jp/crid/1363670320749240448.json","@type":"Article","productIdentifier":[{"identifier":{"@type":"DOI","@value":"10.1093/bja/aen133"}},{"identifier":{"@type":"URI","@value":"https://api.elsevier.com/content/article/PII:S0007091217342332?httpAccept=text/xml"}},{"identifier":{"@type":"URI","@value":"https://api.elsevier.com/content/article/PII:S0007091217342332?httpAccept=text/plain"}},{"identifier":{"@type":"URI","@value":"http://academic.oup.com/bja/article-pdf/101/2/200/721778/aen133.pdf"}}],"dc:title":[{"@value":"Pleth variability index to monitor the respiratory variations in the pulse oximeter plethysmographic waveform amplitude and predict fluid responsiveness in the operating theatre"}],"creator":[{"@id":"https://cir.nii.ac.jp/crid/1380285706238913799","@type":"Researcher","foaf:name":[{"@value":"M. Cannesson"}]},{"@id":"https://cir.nii.ac.jp/crid/1383670320749240449","@type":"Researcher","foaf:name":[{"@value":"O. Desebbe"}]},{"@id":"https://cir.nii.ac.jp/crid/1383670320749240452","@type":"Researcher","foaf:name":[{"@value":"P. Rosamel"}]},{"@id":"https://cir.nii.ac.jp/crid/1383670320749240450","@type":"Researcher","foaf:name":[{"@value":"B. Delannoy"}]},{"@id":"https://cir.nii.ac.jp/crid/1383670320749240453","@type":"Researcher","foaf:name":[{"@value":"J. Robin"}]},{"@id":"https://cir.nii.ac.jp/crid/1383670320749240448","@type":"Researcher","foaf:name":[{"@value":"O. Bastien"}]},{"@id":"https://cir.nii.ac.jp/crid/1383670320749240454","@type":"Researcher","foaf:name":[{"@value":"J.-J. Lehot"}]}],"publication":{"publicationIdentifier":[{"@type":"PISSN","@value":"00070912"}],"prism:publicationName":[{"@value":"British Journal of Anaesthesia"}],"dc:publisher":[{"@value":"Elsevier BV"}],"prism:publicationDate":"2008-08","prism:volume":"101","prism:number":"2","prism:startingPage":"200","prism:endingPage":"206"},"reviewed":"false","dc:rights":["https://www.elsevier.com/tdm/userlicense/1.0/","https://www.elsevier.com/legal/tdmrep-license","http://www.elsevier.com/open-access/userlicense/1.0/"],"url":[{"@id":"https://api.elsevier.com/content/article/PII:S0007091217342332?httpAccept=text/xml"},{"@id":"https://api.elsevier.com/content/article/PII:S0007091217342332?httpAccept=text/plain"},{"@id":"http://academic.oup.com/bja/article-pdf/101/2/200/721778/aen133.pdf"}],"createdAt":"2008-06-03","modifiedAt":"2025-09-13","relatedProduct":[{"@id":"https://cir.nii.ac.jp/crid/1360004235463779328","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@value":"Pleth variability index can predict spinal anaesthesia‐induced hypotension in patients undergoing caesarean delivery"}]},{"@id":"https://cir.nii.ac.jp/crid/1360285706238913664","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@value":"Perfusion index as a possible predictor for postanesthetic shivering"}]},{"@id":"https://cir.nii.ac.jp/crid/1360285707522977920","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@value":"Plethysmography variability index for prediction of fluid responsiveness during graded haemorrhage and transfusion in sevoflurane-anaesthetized mechanically ventilated dogs"}]},{"@id":"https://cir.nii.ac.jp/crid/1390001204759489280","@type":"Article","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@language":"en","@value":"New Algorithm, Perfusion Index (PI), and Pleth Variability Index (PVI) -How to Utilize Them in General Anesthesia Management-"},{"@language":"ja","@value":"新しいアルゴリズム，灌流指標ＰＩ，脈波変動指標ＰＶＩ―全身麻酔管理にどう活かすか―"}]},{"@id":"https://cir.nii.ac.jp/crid/1390001204760229120","@type":"Article","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@language":"en","@value":"Perfusion Index and Pleth Variability Index"},{"@language":"ja","@value":"灌流指標Ｐｅｒｆｕｓｉｏｎ　Ｉｎｄｅｘと脈波変動指標Ｐｌｅｔｈ　Ｖａｒｉａｂｉｌｉｔｙ　Ｉｎｄｅｘ"}]},{"@id":"https://cir.nii.ac.jp/crid/1390282679736212864","@type":"Article","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@language":"en","@value":"The Effectiveness and Limit of SpHb Monitoring on Perioperative Management"},{"@language":"ja","@value":"周術期循環管理における非侵襲的ＳｐＨｂモニターの有用性と限界"}]},{"@id":"https://cir.nii.ac.jp/crid/1390282679736239360","@type":"Article","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@language":"en","@value":"Evolutionary Platform for Growth of Pulse-oximetry"},{"@language":"ja","@value":"周術期モニタリング"}]},{"@id":"https://cir.nii.ac.jp/crid/1390282680712594304","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@language":"en","@value":"The impact of intra-abdominal pressure on the stroke volume variation and plethysmographic variability index in patients undergoing laparoscopic cholecystectomy"}]},{"@id":"https://cir.nii.ac.jp/crid/1390282680714283264","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@language":"en","@value":"Does pneumoperitoneum affect perfusion index and pleth variability index in patients receiving combined epidural and general anesthesia?"}]},{"@id":"https://cir.nii.ac.jp/crid/1390856351209652096","@type":"Article","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@language":"en","@value":"Evolution of the pulse oximeter"},{"@language":"ja","@value":"パルスオキシメータの進化"},{"@language":"ja-Kana","@value":"パルスオキシメータ ノ シンカ"}]}],"dataSourceIdentifier":[{"@type":"CROSSREF","@value":"10.1093/bja/aen133"},{"@type":"CROSSREF","@value":"10.1111/aas.13012_references_DOI_CDj6VwKKiHFsJBt9TGUiaiqsiXC"},{"@type":"CROSSREF","@value":"10.2199/jjsca.31.501_references_DOI_CDj6VwKKiHFsJBt9TGUiaiqsiXC"},{"@type":"CROSSREF","@value":"10.2199/jjsca.31.660_references_DOI_CDj6VwKKiHFsJBt9TGUiaiqsiXC"},{"@type":"CROSSREF","@value":"10.4286/jjmi.92.417_references_DOI_CDj6VwKKiHFsJBt9TGUiaiqsiXC"},{"@type":"CROSSREF","@value":"10.1007/s00540-013-1658-9_references_DOI_CDj6VwKKiHFsJBt9TGUiaiqsiXC"},{"@type":"CROSSREF","@value":"10.2199/jjsca.31.347_references_DOI_CDj6VwKKiHFsJBt9TGUiaiqsiXC"},{"@type":"CROSSREF","@value":"10.2199/jjsca.31.486_references_DOI_CDj6VwKKiHFsJBt9TGUiaiqsiXC"},{"@type":"CROSSREF","@value":"10.1016/j.vaa.2017.07.007_references_DOI_CDj6VwKKiHFsJBt9TGUiaiqsiXC"},{"@type":"CROSSREF","@value":"10.5582/bst.2017.01253_references_DOI_CDj6VwKKiHFsJBt9TGUiaiqsiXC"},{"@type":"CROSSREF","@value":"10.5582/bst.2015.01029_references_DOI_CDj6VwKKiHFsJBt9TGUiaiqsiXC"}]}