{"@context":{"@vocab":"https://cir.nii.ac.jp/schema/1.0/","rdfs":"http://www.w3.org/2000/01/rdf-schema#","dc":"http://purl.org/dc/elements/1.1/","dcterms":"http://purl.org/dc/terms/","foaf":"http://xmlns.com/foaf/0.1/","prism":"http://prismstandard.org/namespaces/basic/2.0/","cinii":"http://ci.nii.ac.jp/ns/1.0/","datacite":"https://schema.datacite.org/meta/kernel-4/","ndl":"http://ndl.go.jp/dcndl/terms/","jpcoar":"https://github.com/JPCOAR/schema/blob/master/2.0/"},"@id":"https://cir.nii.ac.jp/crid/1363949023319206400.json","@type":"Article","productIdentifier":[{"identifier":{"@type":"DOI","@value":"10.1002/ecj.10220"}},{"identifier":{"@type":"URI","@value":"https://api.wiley.com/onlinelibrary/tdm/v1/articles/10.1002%2Fecj.10220"}},{"identifier":{"@type":"URI","@value":"https://onlinelibrary.wiley.com/doi/pdf/10.1002/ecj.10220"}},{"identifier":{"@type":"NAID","@value":"210000166225"}}],"dc:title":[{"@value":"Development of an electrohydraulic total artificial heart system: Improvement of pump unit"}],"description":[{"type":"abstract","notation":[{"@value":"<jats:title>Abstract</jats:title><jats:p>An electrohydraulic total artificial heart (EHTAH) system has been developed. The EHTAH system consists of diaphragm‐type blood pumps, and electrohydraulic actuator, an internal control unit, a transcutaneous energy transfer system (TETS), a transcutaneous optical telemetry system (TOTS), and an internal battery. The reciprocating rotation of the impeller generates oil pressure that drives the blood pumps at alternating intervals. The blood pumps and the actuator were successfully integrated into the pump unit without oil conduits. As a result of miniaturizing the blood pumps and the actuator, the displacement volume and weight of the EHTAH system were decreased to 872 ml and 2492 g, respectively. Furthermore, the maximum flow rate and efficiency increased up to 12 L/min and 15.4%. The pump units and the EHTAH systems were successfully implanted in 36 calves weighing from 55 to 87 kg. In the longest case, a calf with the pump unit survived for 87 days and a calf with the EHTAH system survived for 70 days. The EHTAH system was powered by the TETS, and was powered every day by the internal battery for 40 minutes. These results indicate that the EHTAH system has the potential to become a fully implantable cardiac replacement system. © 2010 Wiley Periodicals, Inc. Electron Comm Jpn, 93(9): 34–46, 2010; Published online in Wiley Online Library (<jats:ext-link xmlns:xlink=\"http://www.w3.org/1999/xlink\" xlink:href=\"http://wileyonlinelibrary.com\">wileyonlinelibrary.com</jats:ext-link>). DOI 10.1002/ecj.10220</jats:p>"}]}],"creator":[{"@id":"https://cir.nii.ac.jp/crid/1583950557781227787","@type":"Researcher","personIdentifier":[{"@type":"NRID","@value":"9000415158448"}],"foaf:name":[{"@value":"Akihiko Homma"}]},{"@id":"https://cir.nii.ac.jp/crid/1583950557781227779","@type":"Researcher","personIdentifier":[{"@type":"NRID","@value":"9000415158449"}],"foaf:name":[{"@value":"Yoshiyuki Taenaka"}]},{"@id":"https://cir.nii.ac.jp/crid/1420564276180328576","@type":"Researcher","personIdentifier":[{"@type":"KAKEN_RESEARCHERS","@value":"00216996"},{"@type":"NRID","@value":"1000000216996"},{"@type":"NRID","@value":"9000255818801"},{"@type":"NRID","@value":"9000415158450"},{"@type":"NRID","@value":"9000398125589"},{"@type":"RESEARCHMAP","@value":"https://researchmap.jp/read0003966"}],"foaf:name":[{"@value":"Eisuke Tatsumi"}]},{"@id":"https://cir.nii.ac.jp/crid/1583950557781227783","@type":"Researcher","personIdentifier":[{"@type":"NRID","@value":"9000415158451"}],"foaf:name":[{"@value":"Yoshiaki Takewa"}]},{"@id":"https://cir.nii.ac.jp/crid/1583950557781227776","@type":"Researcher","personIdentifier":[{"@type":"NRID","@value":"9000415158452"}],"foaf:name":[{"@value":"Toshihide Mizuno"}]},{"@id":"https://cir.nii.ac.jp/crid/1583950557781227786","@type":"Researcher","personIdentifier":[{"@type":"NRID","@value":"9000415158453"}],"foaf:name":[{"@value":"Kyoko Shioya"}]},{"@id":"https://cir.nii.ac.jp/crid/1383949023319206538","@type":"Researcher","foaf:name":[{"@value":"Hwan Sung Lee"}]},{"@id":"https://cir.nii.ac.jp/crid/1583950557781227781","@type":"Researcher","personIdentifier":[{"@type":"NRID","@value":"9000415158455"}],"foaf:name":[{"@value":"Tomonori Tsukiya"}]},{"@id":"https://cir.nii.ac.jp/crid/1583950557781227784","@type":"Researcher","personIdentifier":[{"@type":"NRID","@value":"9000415158456"}],"foaf:name":[{"@value":"Yukihide Kakuta"}]},{"@id":"https://cir.nii.ac.jp/crid/1583950557781227777","@type":"Researcher","personIdentifier":[{"@type":"NRID","@value":"9000415158457"}],"foaf:name":[{"@value":"Nobumasa Katagiri"}]},{"@id":"https://cir.nii.ac.jp/crid/1583950557781227782","@type":"Researcher","personIdentifier":[{"@type":"NRID","@value":"9000415158458"}],"foaf:name":[{"@value":"Tomohiro Nishinaka"}]},{"@id":"https://cir.nii.ac.jp/crid/1583950557781227778","@type":"Researcher","personIdentifier":[{"@type":"NRID","@value":"9000415158459"}],"foaf:name":[{"@value":"Kohji Koshiji"}]}],"publication":{"publicationIdentifier":[{"@type":"PISSN","@value":"19429533"},{"@type":"EISSN","@value":"19429541"}],"prism:publicationName":[{"@value":"Electronics and Communications in Japan"}],"dc:publisher":[{"@value":"Wiley"}],"prism:publicationDate":"2010-08-24","prism:volume":"93","prism:number":"9","prism:startingPage":"34","prism:endingPage":"46"},"reviewed":"false","dc:rights":["http://onlinelibrary.wiley.com/termsAndConditions#vor"],"url":[{"@id":"https://api.wiley.com/onlinelibrary/tdm/v1/articles/10.1002%2Fecj.10220"},{"@id":"https://onlinelibrary.wiley.com/doi/pdf/10.1002/ecj.10220"}],"createdAt":"2010-09-08","modifiedAt":"2023-11-21","foaf:topic":[{"@id":"https://cir.nii.ac.jp/all?q=Applied%20Mathematics","dc:title":"Applied Mathematics"},{"@id":"https://cir.nii.ac.jp/all?q=Electrical%20and%20Electronic%20Engineering","dc:title":"Electrical and Electronic Engineering"},{"@id":"https://cir.nii.ac.jp/all?q=Computer%20Networks%20and%20Communications","dc:title":"Computer Networks and Communications"},{"@id":"https://cir.nii.ac.jp/all?q=General%20Physics%20and%20Astronomy","dc:title":"General Physics and Astronomy"},{"@id":"https://cir.nii.ac.jp/all?q=Signal%20Processing","dc:title":"Signal Processing"}],"relatedProduct":[{"@id":"https://cir.nii.ac.jp/crid/1361418520183126784","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"IN VITRO AND IN VIVO EVALUATION OF LEFT-RIGHT BALANCING ABILITY OF AN INTERATRIAL SHUNT IN AN ELECTROHYDRAULIC TAH (EHTAH) SYSTEM"}]},{"@id":"https://cir.nii.ac.jp/crid/1361418521133500160","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Transcutaneous Optical Telemetry System With Infrared Laser Diode"}]},{"@id":"https://cir.nii.ac.jp/crid/1362825894983565952","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"One Piece Ultracompact Totally Implantable Electromechanical Total Artificial Heart for Permanent Use"}]},{"@id":"https://cir.nii.ac.jp/crid/1362825896149913856","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Selection of a Rechargeable Internal Back-up Battery for a Totally Implantable Artificial Heart"}]},{"@id":"https://cir.nii.ac.jp/crid/1363388843363890560","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"A Transcutaneous Energy Transmission System with Rechargeable Internal Back-up Battery for a Totally Implantable Total Artificial Heart"}]},{"@id":"https://cir.nii.ac.jp/crid/1363670319165246464","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"DEVELOPMENT OF AN ULTRA-COMPACT AND LOW-NOISE PORTABLE DRIVER FOR PNEUMATIC VENTRICULAR ASSIST DEVICES"}]},{"@id":"https://cir.nii.ac.jp/crid/1363951794959806848","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Cardiac Replacement with a Total Artificial Heart as a Bridge to Transplantation"}]},{"@id":"https://cir.nii.ac.jp/crid/1363951794999852160","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Initial experience with the AbioCor implantable replacement heart system"}]},{"@id":"https://cir.nii.ac.jp/crid/1364233268763172352","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Development of mechanical circulatory support devices at the University of Tokyo"}]},{"@id":"https://cir.nii.ac.jp/crid/1370579922347062144","@type":"Product","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Development of portable, small drive device Mobart NCVC for an air‐driven assistive artificial heart that aims to improve safety and QOL for patients with assistive artificial heart devices."}]},{"@id":"https://cir.nii.ac.jp/crid/1373949023319206532","@type":"Product","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Closing behavior of the mechanical heart valve in a total heart."}]},{"@id":"https://cir.nii.ac.jp/crid/1373949023319206534","@type":"Product","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Development of a compact portable driver for pneumatic ventricular assist device."}]}],"dataSourceIdentifier":[{"@type":"CROSSREF","@value":"10.1002/ecj.10220"},{"@type":"CIA","@value":"210000166225"},{"@type":"OPENAIRE","@value":"doi_dedup___::12a0c1c0f309bf58b72096327affa1d7"}]}