{"@context":{"@vocab":"https://cir.nii.ac.jp/schema/1.0/","rdfs":"http://www.w3.org/2000/01/rdf-schema#","dc":"http://purl.org/dc/elements/1.1/","dcterms":"http://purl.org/dc/terms/","foaf":"http://xmlns.com/foaf/0.1/","prism":"http://prismstandard.org/namespaces/basic/2.0/","cinii":"http://ci.nii.ac.jp/ns/1.0/","datacite":"https://schema.datacite.org/meta/kernel-4/","ndl":"http://ndl.go.jp/dcndl/terms/","jpcoar":"https://github.com/JPCOAR/schema/blob/master/2.0/"},"@id":"https://cir.nii.ac.jp/crid/1390001204469870592.json","@type":"Article","productIdentifier":[{"identifier":{"@type":"DOI","@value":"10.24531/jjhs.6.3_201"}},{"identifier":{"@type":"NAID","@value":"110002345797"}},{"identifier":{"@type":"URI","@value":"https://search.jamas.or.jp/link/ui/2004217755"}}],"dc:title":[{"@language":"ja","@value":"ハンドヘルドダイナモメーターによる等尺性膝伸展筋力の測定 : 設定方法の違いが測定値に与える影響"},{"@language":"en","@value":"Measurements of Isometric Knee Extension Force with a Hand-Held Dynamometer : Influence which the Difference in the Setting Method has on Measured value"}],"dc:language":"ja","description":[{"type":"abstract","notation":[{"@language":"ja","@value":"本研究はハンドヘルドダイナモメーターに固定用ベルトを使用した等尺性膝伸展 筋力測定において, 設定方法の違いが測定値に与える影響を検討することを目的とした。 健常者18名の36脚に対して, アニマ社製徒手筋力測定器μTas MF-01 と固定用ベルトを 使用して, 訓練台および車椅子座位での3種類の設定方法にて等尺性膝伸展筋力を測定し た。その結果, 検者内での級内相関係数は, 訓練台上端坐位0.942, 車椅子座位0.767, 車 椅子座位(ベルトを杖と連結) 0.730であった。測定方法間での級内相関係数は, 1日目, 2日目の順に, 訓練台上端坐位一車椅子座位間0.604, 0.655, 訓練台上端坐位一車椅子座位 (ベルトを杖と連結)間0.797, 0.724, 車椅子座位一車椅子座位(ベルトを杖と連結)間 0.621, 0.663であった。したがって, 設定方法の違いが測定値に影響を与え, 訓練台上端 坐位での測定が再現性の見地から適切であると考えられた。"}],"abstractLicenseFlag":"disallow"}],"creator":[{"@id":"https://cir.nii.ac.jp/crid/1410001204468507523","@type":"Researcher","personIdentifier":[{"@type":"NRID","@value":"9000239887671"},{"@type":"NRID","@value":"9000258344060"}],"foaf:name":[{"@language":"ja","@value":"加藤 宗規"},{"@language":"en","@value":"Kato Munenori"}],"jpcoar:affiliationName":[{"@language":"en","@value":"Department of Physical Therapy, Touto Rehabilitation College"},{"@language":"ja","@value":"東都リハビリテーション学院理学療法学科"}]}],"publication":{"publicationIdentifier":[{"@type":"PISSN","@value":"13443844"},{"@type":"EISSN","@value":"2433149X"}],"prism:publicationName":[{"@language":"ja","@value":"東京保健科学学会誌"},{"@language":"en","@value":"The Journal of Tokyo Academy of Health Sciences"},{"@language":"ja","@value":"東京保学誌"},{"@language":"en","@value":"J Tokyo Health Sci"}],"dc:publisher":[{"@language":"en","@value":"Japan Academy of Health Sciences"},{"@language":"ja","@value":"日本保健科学学会"}],"prism:publicationDate":"2003","prism:volume":"6","prism:number":"3","prism:startingPage":"201","prism:endingPage":"204"},"url":[{"@id":"https://search.jamas.or.jp/link/ui/2004217755"}],"availableAt":"2003","foaf:topic":[{"@id":"https://cir.nii.ac.jp/all?q=%E3%83%8F%E3%83%B3%E3%83%89%E3%83%98%E3%83%AB%E3%83%89%E3%83%80%E3%82%A4%E3%83%8A%E3%83%A2%E3%83%A1%E3%83%BC%E3%82%BF%E3%83%BC","dc:title":"ハンドヘルドダイナモメーター"},{"@id":"https://cir.nii.ac.jp/all?q=%E7%AD%89%E5%B0%BA%E6%80%A7%E8%86%9D%E4%BC%B8%E5%B1%95%E7%AD%8B%E5%8A%9B","dc:title":"等尺性膝伸展筋力"},{"@id":"https://cir.nii.ac.jp/all?q=%E5%9B%BA%E5%AE%9A%E7%94%A8%E3%83%99%E3%83%AB%E3%83%88","dc:title":"固定用ベルト"},{"@id":"https://cir.nii.ac.jp/all?q=%E8%A8%AD%E5%AE%9A%E6%96%B9%E6%B3%95","dc:title":"設定方法"},{"@id":"https://cir.nii.ac.jp/all?q=%E5%86%8D%E7%8F%BE%E6%80%A7","dc:title":"再現性"}],"relatedProduct":[{"@id":"https://cir.nii.ac.jp/crid/1572543025588084608","@type":"Article","relationType":["isCitedBy"],"jpcoar:relatedTitle":[{"@language":"ja","@value":"片側人工膝関節全置換術術後の下肢挙上筋力評価"},{"@language":"en","@value":"Muscle strength evaluation of quadriceps femoris in knee extension after unilateral total knee arthroplasty"}]}],"dataSourceIdentifier":[{"@type":"JALC","@value":"oai:japanlinkcenter.org:2003390089"},{"@type":"CIA","@value":"110002345797"}]}