Improvement of Thomson Scattering Diagnostics Using Stimulated-Brillouin-Scattering-Based Phase Conjugate Mirrors
-
- HATAE Takaki
- Naka Fusion Research Establishment, Japan Atomic Energy Research Institute
-
- NAKATSUKA Masahiro
- Institute of Laser Engineering, Osaka University
-
- YOSHIDA Hidetsugu
- Institute of Laser Engineering, Osaka University
この論文をさがす
抄録
In order to improve the measurement performance of incoherent Thomson scattering diagnostics, a high performance phase conjugate mirror based on stimulated Brillouin scattering (SBS-PCM) is applied to a Thomson scattering system for the first time in the JT-60U tokamak. We have demonstrated that a SBS-PCM which uses heavy-fluorocarbon liquid showed a high reflectivity of 95% at a high input-power of 145 W. Using the SBS-PCM, two newly developed methods were employed to increase the amount of scattered light. In the first method, we first developed a new optical design to provide a double-pass scattering scheme with the SBS-PCM. In this new optical design, a laser beam passing through the plasma is reflected by the SBS-PCM, and the reflected beam is returned via the same path by means of the phase conjugate effect, and is then passed through the plasma again, in order to increase the scattered light. A double-pass Thomson scattering scheme using the SBS-PCM was demonstrated in JT-60U ohmic plasma, resulting in an increase of the scattered light by a factor of 1.6, and the reduction of relative error by 2/3 for electron temperature measurement in contrast to single-pass scattering. A multi-pass Thomson scattering scheme is also proposed based on the results of double-pass scattering. It is estimated that multi-pass scattering allows the generation of several times the amount of scattered light, and the reduction of the relative error for electron temperature measurement by 37% in contrast to single-pass scattering. Regarding the second method, a high average-power of YAG laser system was developed by applying the SBS-PCM to a existent diagnostic laser. As a result, the average-power was increased by over 8 times in contrast to the average power of the original system, achieving up to 368 W (7.4 J × 50 Hz).
収録刊行物
-
- プラズマ・核融合学会誌
-
プラズマ・核融合学会誌 80 (10), 870-882, 2004
社団法人 プラズマ・核融合学会
- Tweet
キーワード
詳細情報
-
- CRID
- 1390001206511923584
-
- NII論文ID
- 110003827868
-
- NII書誌ID
- AN10401672
-
- COI
- 1:CAS:528:DC%2BD2cXhtFWqu7rN
-
- NDL書誌ID
- 7137862
-
- ISSN
- 09187928
-
- 本文言語コード
- en
-
- データソース種別
-
- JaLC
- NDL
- Crossref
- NDL-Digital
- CiNii Articles
-
- 抄録ライセンスフラグ
- 使用不可