{"@context":{"@vocab":"https://cir.nii.ac.jp/schema/1.0/","rdfs":"http://www.w3.org/2000/01/rdf-schema#","dc":"http://purl.org/dc/elements/1.1/","dcterms":"http://purl.org/dc/terms/","foaf":"http://xmlns.com/foaf/0.1/","prism":"http://prismstandard.org/namespaces/basic/2.0/","cinii":"http://ci.nii.ac.jp/ns/1.0/","datacite":"https://schema.datacite.org/meta/kernel-4/","ndl":"http://ndl.go.jp/dcndl/terms/","jpcoar":"https://github.com/JPCOAR/schema/blob/master/2.0/"},"@id":"https://cir.nii.ac.jp/crid/1390006817998385280.json","@type":"Article","productIdentifier":[{"identifier":{"@type":"DOI","@value":"10.15261/serdj.28.11"}},{"identifier":{"@type":"NDL_BIB_ID","@value":"031626993"}},{"identifier":{"@type":"URI","@value":"http://id.ndl.go.jp/bib/031626993"}},{"identifier":{"@type":"URI","@value":"https://ndlsearch.ndl.go.jp/books/R000000004-I031626993"}},{"identifier":{"@type":"URI","@value":"https://www.jstage.jst.go.jp/article/serdj/28/1/28_11/_pdf"}},{"identifier":{"@type":"NAID","@value":"130008049535"}}],"dc:title":[{"@language":"en","@value":"Axial Mixing in Emulsion-flow Column under Iodine Extraction"}],"dc:language":"en","description":[{"type":"abstract","notation":[{"@language":"en","@value":"<p>Strength of axial mixing in the emulsion phase during the progress of extraction was evaluated using the Peclet number under various flow conditions. The Peclet numbers were determined with the established tracer technology which applies inert species for iodine extraction. Very little effect of operating velocities of either aqueous and organic phases was found on the Peclet numbers. This fact indicates that an almost constant degree of axial mixing was kept in this column for different flow velocities of both phases. Furthermore, the degree of axial mixing of the emulsion-flow column was compared with conventional spray and packed columns by plotting the droplet Peclet number against the droplet Reynolds number. Points of the Peclet numbers of emulsion-flow column located in the middle of the spray and the packed columns, which suggests that the strength of axial mixing in the present column is in between spray and packed columns. </p>"}],"abstractLicenseFlag":"disallow"}],"creator":[{"@id":"https://cir.nii.ac.jp/crid/1410006817998385281","@type":"Researcher","personIdentifier":[{"@type":"NRID","@value":"9000412323235"}],"foaf:name":[{"@language":"en","@value":"HIRAYAMA Mikiro"}],"jpcoar:affiliationName":[{"@language":"en","@value":"Department of Chemical Engineering, Kagoshima University"}]},{"@id":"https://cir.nii.ac.jp/crid/1410006817998385283","@type":"Researcher","personIdentifier":[{"@type":"NRID","@value":"9000412323236"}],"foaf:name":[{"@language":"en","@value":"GOSHIMA Takashi"}],"jpcoar:affiliationName":[{"@language":"en","@value":"Department of Chemical Engineering, Kagoshima University"}]},{"@id":"https://cir.nii.ac.jp/crid/1410006817998385282","@type":"Researcher","personIdentifier":[{"@type":"NRID","@value":"9000412323237"}],"foaf:name":[{"@language":"en","@value":"MIZUTA Kei"}],"jpcoar:affiliationName":[{"@language":"en","@value":"Department of Chemical Engineering, Kagoshima University"}]},{"@id":"https://cir.nii.ac.jp/crid/1410006817998385280","@type":"Researcher","personIdentifier":[{"@type":"NRID","@value":"9000412323238"}],"foaf:name":[{"@language":"en","@value":"NII Susumu"}],"jpcoar:affiliationName":[{"@language":"en","@value":"Department of Chemical Engineering, Kagoshima University"}]}],"publication":{"publicationIdentifier":[{"@type":"PISSN","@value":"13417215"},{"@type":"LISSN","@value":"13417215"},{"@type":"EISSN","@value":"21884765"},{"@type":"NDL_BIB_ID","@value":"000000156123"},{"@type":"ISSN","@value":"13417215"},{"@type":"NCID","@value":"AA11114608"}],"prism:publicationName":[{"@language":"en","@value":"Solvent Extraction Research and Development, Japan"},{"@language":"ja","@value":"Solvent Extraction Research and Development, Japan"},{"@language":"en","@value":"SERDJ"},{"@language":"ja","@value":"抽出学会誌"}],"dc:publisher":[{"@language":"en","@value":"Japan Association of Solvent Extraction"},{"@language":"ja","@value":"日本溶媒抽出学会"}],"prism:publicationDate":"2021","prism:volume":"28","prism:number":"1","prism:startingPage":"11","prism:endingPage":"19"},"reviewed":"false","dcterms:accessRights":"http://purl.org/coar/access_right/c_abf2","url":[{"@id":"http://id.ndl.go.jp/bib/031626993"},{"@id":"https://ndlsearch.ndl.go.jp/books/R000000004-I031626993"},{"@id":"https://www.jstage.jst.go.jp/article/serdj/28/1/28_11/_pdf"}],"availableAt":"2021","foaf:topic":[{"@id":"https://cir.nii.ac.jp/all?q=General%20Chemical%20Engineering","dc:title":"General Chemical Engineering"},{"@id":"https://cir.nii.ac.jp/all?q=General%20Chemistry","dc:title":"General Chemistry"}],"relatedProduct":[{"@id":"https://cir.nii.ac.jp/crid/1360574094181107712","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Estimation of Effective Transport Properties in Packed Bed Reactors"}]},{"@id":"https://cir.nii.ac.jp/crid/1360855570532576768","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Axial dispersion in packed beds"}]},{"@id":"https://cir.nii.ac.jp/crid/1360855571244145024","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Fluid dispersion-generalization and comparison of mathematical models—I generalization of models"}]},{"@id":"https://cir.nii.ac.jp/crid/1361418518828565120","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Continuous flow systems"}]},{"@id":"https://cir.nii.ac.jp/crid/1361981470714075392","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Factors Influencing the Efficiency of Miscible Displacement"}]},{"@id":"https://cir.nii.ac.jp/crid/1361981470744977152","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Axial dispersion coefficients of the continuous phase in liquid-liquid spray towers"}]},{"@id":"https://cir.nii.ac.jp/crid/1362262946071420928","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Continuous-Phase Axial Dispersion in Liquid-Liquid Spray Towers"}]},{"@id":"https://cir.nii.ac.jp/crid/1362544420652972160","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Longitudinal Diffusivity of Liquids in Packed Beds"}]},{"@id":"https://cir.nii.ac.jp/crid/1362825894107431296","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Hydrodynamics of a pilot plant spray extraction column"}]},{"@id":"https://cir.nii.ac.jp/crid/1363107368928497920","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Axial Dispersion in a Spray-Type Extraction Tower"}]},{"@id":"https://cir.nii.ac.jp/crid/1363670318885468928","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Notes on the diffusion-type model for the longitudinal mixing of fluids in flow"}]},{"@id":"https://cir.nii.ac.jp/crid/1363951794298851712","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Axial dispersion in liquid flow through packed beds"}]},{"@id":"https://cir.nii.ac.jp/crid/1364233268420041856","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Longitudinal Dispersion of the Continuous Phase in Spray Extraction Columns"}]},{"@id":"https://cir.nii.ac.jp/crid/1364233269189865856","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Axial dispersion of mass in flow through fixed beds"}]},{"@id":"https://cir.nii.ac.jp/crid/1364233269833655040","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Mixing of fluids flowing through beds of packed solids"}]},{"@id":"https://cir.nii.ac.jp/crid/1390006839645942144","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@language":"en","@value":"Evaluation of Mass-transfer Performance of Emulsion-flow Column with Height of Transfer Unit (HTU) and Number of Theoretical Plates, and Comparison of HTU with Column-type Extractors"}]},{"@id":"https://cir.nii.ac.jp/crid/1390014746557045504","@type":"Article","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@language":"en","@value":"Flow Characteristics and Mass-Transfer in Droplet Layer Formed in an Emulsion-Flow Column by Using Extraction of Iodine from Organic Phase"}]},{"@id":"https://cir.nii.ac.jp/crid/1390282679237125632","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["references"],"jpcoar:relatedTitle":[{"@language":"en","@value":"New Apparatus for Liquid-Liquid Extraction, \"Emulsion Flow\" Extractor"}]},{"@id":"https://cir.nii.ac.jp/crid/1390282679486708864","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"充てん層の軸方向混合特性　　側混合モデルによる解析"},{"@language":"en","@value":"Axial Mixing Characteristics in Packed Beds"},{"@language":"ja-Kana","@value":"ジュウテンソウ ノ ジク ホウコウ コンゴウ トクセイ ガワ コンゴウ モデル"}]},{"@id":"https://cir.nii.ac.jp/crid/1390282679638355840","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["references"],"jpcoar:relatedTitle":[{"@language":"ja","@value":"新しい液液抽出法\"エマルションフロー法\""},{"@language":"en","@value":"New Liquid-liquid Extraction Apparatus, \"Emulsion-flow\" Extractor"},{"@language":"ja-Kana","@value":"アタラシイエキエキ チュウシュツホウ\"エマルションフローホウ\""}]},{"@id":"https://cir.nii.ac.jp/crid/1390282680717860224","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@language":"en","@value":"Continuous Liquid-Liquid Extraction of Nickel from Simulated Electroless Nickel Plating Liquid Wastes by Using a Counter Current Emulsion Flow Extractor"},{"@value":"Continuous Liquid-Liquid Extraction of Nickel from Simulated Electroless Nickel Plating Liquid Wastes by a Using Counter Current Emulsion flow Extractor"}]},{"@id":"https://cir.nii.ac.jp/crid/1390282752324873088","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["references"],"jpcoar:relatedTitle":[{"@language":"en","@value":"Size Distribution of Droplets in a Two Liquid-phase Mixture Compared between Liquid Spraying and Mechanical Stirring"}]},{"@id":"https://cir.nii.ac.jp/crid/1390568456335357824","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@language":"en","@value":"Quantification of Iodine Mass Transfer and Height of Emulsion Phase in “Emulsion-flow” Column"}]},{"@id":"https://cir.nii.ac.jp/crid/1390584708066720512","@type":"Article","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@language":"en","@value":"Application of Queueing Theory and Foam Drainage Model to Enhance Understanding of Droplet Layer in Emulsion-flow Column Extractor"}]},{"@id":"https://cir.nii.ac.jp/crid/1390845712997264000","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["references"],"jpcoar:relatedTitle":[{"@language":"en","@value":"Continuous Liquid–Liquid Extraction of Uranium from Uranium-containing Wastewater Using an Organic Phase-refining-type Emulsion Flow Extractor"}]}],"dataSourceIdentifier":[{"@type":"JALC","@value":"oai:japanlinkcenter.org:2008486364"},{"@type":"NDL_SEARCH","@value":"oai:ndlsearch.ndl.go.jp:R000000004-I031626993"},{"@type":"CROSSREF","@value":"10.15261/serdj.28.11"},{"@type":"CIA","@value":"130008049535"},{"@type":"OPENAIRE","@value":"doi_dedup___::233dc2604cc5dfe80f33243363b31f45"},{"@type":"CROSSREF","@value":"10.15261/serdj.32.9_references_DOI_SXqVwWpdFrUuJZmTwWMWr0uePR2"},{"@type":"CROSSREF","@value":"10.15261/serdj.30.159_references_DOI_SXqVwWpdFrUuJZmTwWMWr0uePR2"},{"@type":"CROSSREF","@value":"10.2116/analsci.20p320_references_DOI_SXqVwWpdFrUuJZmTwWMWr0uePR2"}]}