{"@context":{"@vocab":"https://cir.nii.ac.jp/schema/1.0/","rdfs":"http://www.w3.org/2000/01/rdf-schema#","dc":"http://purl.org/dc/elements/1.1/","dcterms":"http://purl.org/dc/terms/","foaf":"http://xmlns.com/foaf/0.1/","prism":"http://prismstandard.org/namespaces/basic/2.0/","cinii":"http://ci.nii.ac.jp/ns/1.0/","datacite":"https://schema.datacite.org/meta/kernel-4/","ndl":"http://ndl.go.jp/dcndl/terms/","jpcoar":"https://github.com/JPCOAR/schema/blob/master/2.0/"},"@id":"https://cir.nii.ac.jp/crid/1390016449445648896.json","@type":"Article","productIdentifier":[{"identifier":{"@type":"DOI","@value":"10.18948/shasetaikai.2022.7.0_157"}}],"dc:title":[{"@language":"en","@value":"Field Measurement of Micro-Plastic Concentration in Indoor Environment  (Part4) Identification of microplastic components by LDIR analysis and adsorption SVOC concentration"},{"@language":"ja","@value":"居住空間におけるマイクロプラスチック問題の実態調査　（第4報）LDIR分析によるハウスダスト中のマイクロプラスチックの成分同定と表面吸着成分"}],"dc:language":"ja","description":[{"type":"abstract","notation":[{"@language":"ja","@value":"<p>本報を含む一連の研究では室内環境中で床面に沈着したマイクロプラスチックを対象として，そのサンプリング･分析法を検討した上で, 室内環境中に存在するマイクロプラスチック汚染の実態把握を目的とする．今回は関東地方の住宅におけるハウスダスト中のマイクロプラスチック問題について調査した．本報では，Laser Direct InfraRed (LDIR)ケミカルイメージングシステムを用いた定性分析結果とSVOC分析によるハウスダストの表面吸着成分分析結果について報告する．</p>"}],"abstractLicenseFlag":"disallow"}],"creator":[{"@id":"https://cir.nii.ac.jp/crid/1410016449445648901","@type":"Researcher","foaf:name":[{"@language":"ja","@value":"柏 一凡"}],"jpcoar:affiliationName":[{"@language":"ja","@value":"東洋大学"}]},{"@id":"https://cir.nii.ac.jp/crid/1410016449445648897","@type":"Researcher","foaf:name":[{"@language":"ja","@value":"倪 源"}],"jpcoar:affiliationName":[{"@language":"ja","@value":"東洋大学"}]},{"@id":"https://cir.nii.ac.jp/crid/1410016449445648898","@type":"Researcher","foaf:name":[{"@language":"ja","@value":"イム ウンス"}],"jpcoar:affiliationName":[{"@language":"ja","@value":"東洋大学"}]},{"@id":"https://cir.nii.ac.jp/crid/1410016449445648899","@type":"Researcher","foaf:name":[{"@language":"ja","@value":"黒須 俊治"}],"jpcoar:affiliationName":[{"@language":"ja","@value":"東洋大学"}]},{"@id":"https://cir.nii.ac.jp/crid/1410016449445648900","@type":"Researcher","foaf:name":[{"@language":"ja","@value":"伊藤 一秀"}],"jpcoar:affiliationName":[{"@language":"ja","@value":"九州大学"}]},{"@id":"https://cir.nii.ac.jp/crid/1410016449445648896","@type":"Researcher","foaf:name":[{"@language":"ja","@value":"田中 浩史"}],"jpcoar:affiliationName":[{"@language":"ja","@value":"株式会社　MCエバテック"}]}],"publication":{"publicationIdentifier":[{"@type":"PISSN","@value":"18803806"},{"@type":"EISSN","@value":"24242179"}],"prism:publicationName":[{"@language":"ja","@value":"空気調和・衛生工学会大会　学術講演論文集"},{"@language":"en","@value":"Techinical Papers of Annual Meeting the Society of Heating,Air-conditioning and Sanitary Engineers of Japan"}],"dc:publisher":[{"@language":"en","@value":"The Society of Heating,Air-Conditioning&Sanitary Engineers of Japan"},{"@language":"ja","@value":"公益社団法人 空気調和・衛生工学会"}],"prism:publicationDate":"2022","prism:volume":"2022.7","prism:number":"0","prism:startingPage":"157","prism:endingPage":"160"},"jpcoar:conferenceName":"令和４年度空気調和・衛生工学会大会（神戸）","availableAt":"2022","foaf:topic":[{"@id":"https://cir.nii.ac.jp/all?q=Indoor%20environment","dc:title":"Indoor environment"},{"@id":"https://cir.nii.ac.jp/all?q=Microplastics","dc:title":"Microplastics"},{"@id":"https://cir.nii.ac.jp/all?q=Micro%20fiber","dc:title":"Micro fiber"},{"@id":"https://cir.nii.ac.jp/all?q=House%20dust","dc:title":"House dust"},{"@id":"https://cir.nii.ac.jp/all?q=%C2%B5-FT-IR","dc:title":"µ-FT-IR"},{"@id":"https://cir.nii.ac.jp/all?q=LDIR","dc:title":"LDIR"}],"dataSourceIdentifier":[{"@type":"JALC","@value":"oai:japanlinkcenter.org:2011807573"}]}