{"@context":{"@vocab":"https://cir.nii.ac.jp/schema/1.0/","rdfs":"http://www.w3.org/2000/01/rdf-schema#","dc":"http://purl.org/dc/elements/1.1/","dcterms":"http://purl.org/dc/terms/","foaf":"http://xmlns.com/foaf/0.1/","prism":"http://prismstandard.org/namespaces/basic/2.0/","cinii":"http://ci.nii.ac.jp/ns/1.0/","datacite":"https://schema.datacite.org/meta/kernel-4/","ndl":"http://ndl.go.jp/dcndl/terms/","jpcoar":"https://github.com/JPCOAR/schema/blob/master/2.0/"},"@id":"https://cir.nii.ac.jp/crid/1390282679538657152.json","@type":"Article","productIdentifier":[{"identifier":{"@type":"DOI","@value":"10.11330/jtss.53.103"}},{"identifier":{"@type":"NDL_BIB_ID","@value":"027574916"}},{"identifier":{"@type":"URI","@value":"http://id.ndl.go.jp/bib/027574916"}},{"identifier":{"@type":"URI","@value":"https://ndlsearch.ndl.go.jp/books/R000000004-I027574916"}},{"identifier":{"@type":"NAID","@value":"130005411078"}}],"dc:title":[{"@language":"ja","@value":"Al-5Mg合金溶射皮膜における添加元素が引張密着強度に及ぼす影響"},{"@language":"en","@value":"Effect of Additional Elements on Tensile Adhesive Strength of Sprayed Al-5Mg Coatings"},{"@language":"ja-Kana","@value":"Al-5Mg ゴウキン ヨウシャ ヒマク ニ オケル テンカ ゲンソ ガ ヒッパリ ミッチャク キョウド ニ オヨボス エイキョウ"}],"dc:language":"ja","description":[{"type":"abstract","notation":[{"@language":"en","@value":"Sprayed Al-5Mg coating is widely used as a protection against corrosion on infrastructures composed of steels, such as bridges and elevated roads near seacoast. Previously, the first-principles calculation had indicated that additional metals of Sn, Li, Zn, Ca, Y and Bi have a possibility to improve cathodic protection ability for sprayed Al-5Mg coatings. In this paper, those additional metals effects on tensile adhesive strength of sprayed Al-5Mg coatings were examined. Consequently, the tensile adhesive strength of the sprayed Al-5Mg coating was 8 MPa, and those of 0.35 mass% Sn, 2.95 mass% Zn, 0.16 mass% Ca, 0.04 mass% Y and 0.19 mass% Bi added coatings were over 8 MPa. By contrast, 0.23 mass% Li added coating was 7 MPa, reduced in strength,because the hardness of its coating became lower. It was recognized that additional metals of Sn, Zn, Ca, Y and Bi were not reduce the tensile adhesive strength of sprayed Al-5Mg coating."}],"abstractLicenseFlag":"disallow"}],"creator":[{"@id":"https://cir.nii.ac.jp/crid/1420282801187220224","@type":"Researcher","personIdentifier":[{"@type":"KAKEN_RESEARCHERS","@value":"50359410"},{"@type":"NRID","@value":"1000050359410"},{"@type":"NRID","@value":"9000017115618"},{"@type":"NRID","@value":"9000391522688"},{"@type":"NRID","@value":"9000303919555"},{"@type":"NRID","@value":"9000403032609"},{"@type":"NRID","@value":"9000017948743"},{"@type":"NRID","@value":"9000363179181"},{"@type":"NRID","@value":"9000345404172"}],"foaf:name":[{"@language":"ja","@value":"足立 振一郎"},{"@language":"en","@value":"ADACHI Shinichiro"}],"jpcoar:affiliationName":[{"@language":"en","@value":"Technology Research Institute of Osaka Prefecture"},{"@language":"ja","@value":"大阪府立産業技術総合研究所"}]},{"@id":"https://cir.nii.ac.jp/crid/1410282679538657155","@type":"Researcher","personIdentifier":[{"@type":"NRID","@value":"9000345404173"}],"foaf:name":[{"@language":"ja","@value":"井上 博之"},{"@language":"en","@value":"INOUE Hiroyuki"}],"jpcoar:affiliationName":[{"@language":"en","@value":"大阪府立大学"},{"@language":"ja","@value":"Osaka Prefecture University"}]},{"@id":"https://cir.nii.ac.jp/crid/1420564276181797248","@type":"Researcher","personIdentifier":[{"@type":"KAKEN_RESEARCHERS","@value":"10405342"},{"@type":"NRID","@value":"1000010405342"},{"@type":"NRID","@value":"9000003631899"},{"@type":"NRID","@value":"9000402786204"},{"@type":"NRID","@value":"9000257851165"},{"@type":"NRID","@value":"9000257844377"},{"@type":"NRID","@value":"9000001579953"},{"@type":"NRID","@value":"9000326649377"},{"@type":"NRID","@value":"9000399378189"},{"@type":"NRID","@value":"9000248199203"},{"@type":"NRID","@value":"9000263062749"},{"@type":"NRID","@value":"9000257849539"},{"@type":"NRID","@value":"9000261028372"},{"@type":"NRID","@value":"9000410334892"},{"@type":"NRID","@value":"9000021340470"},{"@type":"NRID","@value":"9000347131787"},{"@type":"NRID","@value":"9000257852373"},{"@type":"NRID","@value":"9000257989484"},{"@type":"NRID","@value":"9000391522689"},{"@type":"NRID","@value":"9000404822447"},{"@type":"NRID","@value":"9000259332682"},{"@type":"NRID","@value":"9000021122824"},{"@type":"NRID","@value":"9000309161709"},{"@type":"NRID","@value":"9000386206661"},{"@type":"NRID","@value":"9000316209879"},{"@type":"NRID","@value":"9000410514211"},{"@type":"NRID","@value":"9000309161266"},{"@type":"NRID","@value":"9000257848867"},{"@type":"NRID","@value":"9000415427042"},{"@type":"NRID","@value":"9000415044545"},{"@type":"NRID","@value":"9000266427899"},{"@type":"NRID","@value":"9000261028381"},{"@type":"NRID","@value":"9000000497472"},{"@type":"NRID","@value":"9000410957733"},{"@type":"NRID","@value":"9000399361154"},{"@type":"NRID","@value":"9000398984921"},{"@type":"NRID","@value":"9000409878516"},{"@type":"NRID","@value":"9000257850918"},{"@type":"NRID","@value":"9000411836637"},{"@type":"NRID","@value":"9000021346527"},{"@type":"NRID","@value":"9000309161262"},{"@type":"NRID","@value":"9000309161307"},{"@type":"NRID","@value":"9000390885981"},{"@type":"NRID","@value":"9000412040027"},{"@type":"NRID","@value":"9000257839335"},{"@type":"NRID","@value":"9000258728332"},{"@type":"NRID","@value":"9000345404174"},{"@type":"NRID","@value":"9000408583326"},{"@type":"NRID","@value":"9000410731493"},{"@type":"NRID","@value":"9000406387769"},{"@type":"RESEARCHMAP","@value":"https://researchmap.jp/UT001146"}],"foaf:name":[{"@language":"ja","@value":"上杉 徳照"},{"@language":"en","@value":"UESUGI Tokuteru"}],"jpcoar:affiliationName":[{"@language":"en","@value":"大阪府立大学"},{"@language":"ja","@value":"Osaka Prefecture University"}]},{"@id":"https://cir.nii.ac.jp/crid/1410001204560103683","@type":"Researcher","personIdentifier":[{"@type":"NRID","@value":"9000392610104"}],"foaf:name":[{"@language":"ja","@value":"東 健司"},{"@language":"en","@value":"HIGASHI Kenji"}],"jpcoar:affiliationName":[{"@language":"en","@value":"大阪府立大学"},{"@language":"ja","@value":"Osaka Prefecture University"}]},{"@id":"https://cir.nii.ac.jp/crid/1410282679538657154","@type":"Researcher","personIdentifier":[{"@type":"NRID","@value":"9000345404176"}],"foaf:name":[{"@language":"ja","@value":"植野 修一"},{"@language":"en","@value":"UENO Syuichi"}],"jpcoar:affiliationName":[{"@language":"en","@value":"Kanmeta Engineering Co.,Ltd."},{"@language":"ja","@value":"カンメタエンジニアリング株式会社"}]}],"publication":{"publicationIdentifier":[{"@type":"PISSN","@value":"09166076"},{"@type":"LISSN","@value":"09166076"},{"@type":"EISSN","@value":"21861080"},{"@type":"NDL_BIB_ID","@value":"000000074217"},{"@type":"ISSN","@value":"09166076"},{"@type":"NCID","@value":"AN10502250"}],"prism:publicationName":[{"@language":"ja","@value":"日本溶射学会誌　溶射"},{"@language":"en","@value":"Journal of Japan Thermal Spray Society"},{"@language":"en","@value":"Jornal of Japan Thermal Spray Society"},{"@language":"en","@value":"JJTSS"},{"@language":"en","@value":"JTSS"},{"@language":"ja","@value":"溶射"}],"dc:publisher":[{"@language":"en","@value":"Japan Thermal Spray Society"},{"@language":"ja","@value":"一般社団法人 日本溶射学会"}],"prism:publicationDate":"2016","prism:volume":"53","prism:number":"3","prism:startingPage":"103","prism:endingPage":"105"},"url":[{"@id":"http://id.ndl.go.jp/bib/027574916"},{"@id":"https://ndlsearch.ndl.go.jp/books/R000000004-I027574916"}],"availableAt":"2016","dataSourceIdentifier":[{"@type":"JALC","@value":"oai:japanlinkcenter.org:2001266224"},{"@type":"NDL_SEARCH","@value":"oai:ndlsearch.ndl.go.jp:R000000004-I027574916"},{"@type":"CIA","@value":"130005411078"}]}