{"@context":{"@vocab":"https://cir.nii.ac.jp/schema/1.0/","rdfs":"http://www.w3.org/2000/01/rdf-schema#","dc":"http://purl.org/dc/elements/1.1/","dcterms":"http://purl.org/dc/terms/","foaf":"http://xmlns.com/foaf/0.1/","prism":"http://prismstandard.org/namespaces/basic/2.0/","cinii":"http://ci.nii.ac.jp/ns/1.0/","datacite":"https://schema.datacite.org/meta/kernel-4/","ndl":"http://ndl.go.jp/dcndl/terms/","jpcoar":"https://github.com/JPCOAR/schema/blob/master/2.0/"},"@id":"https://cir.nii.ac.jp/crid/1390282679581237504.json","@type":"Article","productIdentifier":[{"identifier":{"@type":"DOI","@value":"10.1541/ieejpes1990.121.9_1130"}},{"identifier":{"@type":"NDL_BIB_ID","@value":"5894307"}},{"identifier":{"@type":"URI","@value":"http://id.ndl.go.jp/bib/5894307"}},{"identifier":{"@type":"URI","@value":"https://ndlsearch.ndl.go.jp/books/R000000004-I5894307"}},{"identifier":{"@type":"URI","@value":"https://www.jstage.jst.go.jp/article/ieejpes1990/121/9/121_9_1130/_pdf"}},{"identifier":{"@type":"NAID","@value":"130006841042"}},{"identifier":{"@type":"NAID","@value":"10006759121"}}],"dc:title":[{"@language":"ja","@value":"ダイオード・他励ハイブリッド順変換所と自励逆変換所の組合せによるHVDCシステムの提案と解析結果"},{"@language":"en","@value":"Proposal and Digital Analysis of HVDC Transmission Systems Incorporating Hybrid Diode and Thyristor Rectifiers and Voltage Source Inverters"},{"@language":"ja-Kana","@value":"ダイオード タレイハイブリッドジュン ヘンカンショ ト ジレイギャクヘンカンショ ノ クミアワセ ニ ヨル HVDC システム ノ テイアン ト カイセキ ケッカ"}],"description":[{"type":"abstract","notation":[{"@language":"en","@value":"Many researchers have proposed the application of diode rectifiers in the HVdc transmission systems, the major objective of which is cost reduction. However, simple replacement of thyristor converters at the rectifier station with diode ones while keeping line-commutated thyristor inverters on the other end will cause several problems which degrades HVdc system performance to a level that the HVdc system becomes impractical. The major problems are: (1) dc line overvoltage upon startup of the system, (2) large fault current upon occurence of dc line grounding fault, and (3) commutation failure of the inverters. To overcome these problems while almost keeping the cost reduction merit, the authors discuss the possible combination of diode rectifiers, line commutated thyristor converters and the voltage source converters. Series connection of diode and thyristor converters in the rectifier stations (which is called diode-thyristor hybrid rectifier station scheme) will solve problems (1) and (2). The use of voltage source converters in the inverter stations will remove problem (3). This combination will be a cost-effective solution when there is no need for bi-directional power flow and when the receiving end network needs the ability of voltage source inverters."}],"abstractLicenseFlag":"disallow"}],"creator":[{"@id":"https://cir.nii.ac.jp/crid/1410001204656315265","@type":"Researcher","personIdentifier":[{"@type":"NRID","@value":"9000003784803"},{"@type":"NRID","@value":"9000415157041"},{"@type":"NRID","@value":"9000315144331"},{"@type":"RESEARCHMAP","@value":"https://researchmap.jp/read0210080"}],"foaf:name":[{"@language":"ja","@value":"高木 亮"},{"@language":"en","@value":"TAKAGI Ryo"}],"jpcoar:affiliationName":[{"@language":"en","@value":"Tokyo Electric Power Co., Inc."},{"@language":"ja","@value":"東京電力"}]},{"@id":"https://cir.nii.ac.jp/crid/1420845751135915904","@type":"Researcher","personIdentifier":[{"@type":"KAKEN_RESEARCHERS","@value":"10212086"},{"@type":"NRID","@value":"1000010212086"},{"@type":"NRID","@value":"9000000164603"},{"@type":"NRID","@value":"9000240529399"},{"@type":"NRID","@value":"9000378058138"},{"@type":"NRID","@value":"9000369725302"},{"@type":"NRID","@value":"9000369725319"},{"@type":"NRID","@value":"9000415228049"},{"@type":"NRID","@value":"9000238251571"},{"@type":"NRID","@value":"9000391534756"},{"@type":"NRID","@value":"9000391539082"},{"@type":"NRID","@value":"9000369725312"},{"@type":"NRID","@value":"9000415149134"},{"@type":"NRID","@value":"9000415194988"},{"@type":"NRID","@value":"9000107370316"},{"@type":"NRID","@value":"9000404306370"},{"@type":"NRID","@value":"9000415175028"},{"@type":"NRID","@value":"9000356620754"},{"@type":"NRID","@value":"9000368919122"},{"@type":"NRID","@value":"9000391534701"},{"@type":"NRID","@value":"9000370240891"},{"@type":"NRID","@value":"9000368919002"},{"@type":"NRID","@value":"9000391535313"},{"@type":"NRID","@value":"9000368919060"},{"@type":"NRID","@value":"9000390926179"},{"@type":"NRID","@value":"9000391539326"},{"@type":"RESEARCHMAP","@value":"https://researchmap.jp/nakajima_tatsuhito"}],"foaf:name":[{"@language":"ja","@value":"中島 達人"},{"@language":"en","@value":"NAKAJIMA Tatsuhito"}],"jpcoar:affiliationName":[{"@language":"en","@value":"Tokyo Electric Power Co., Inc."},{"@language":"ja","@value":"東京電力"}]}],"publication":{"publicationIdentifier":[{"@type":"PISSN","@value":"03854213"},{"@type":"LISSN","@value":"03854213"},{"@type":"EISSN","@value":"13488147"},{"@type":"NDL_BIB_ID","@value":"000000015706"},{"@type":"ISSN","@value":"03854213"},{"@type":"NCID","@value":"AN10136334"}],"prism:publicationName":[{"@language":"en","@value":"IEEJ Transactions on Power and Energy"},{"@language":"ja","@value":"電気学会論文誌Ｂ（電力・エネルギー部門誌）"},{"@language":"ja","@value":"電気学会論文誌．　Ｂ"},{"@value":"電気学会論文誌. B"},{"@language":"en","@value":"IEEJ Trans. PE"},{"@language":"ja","@value":"電学論Ｂ"},{"@language":"en","@value":"IEEJ Trans.PE"},{"@language":"ja","@value":"電気学会論文誌．　Ｂ"}],"dc:publisher":[{"@language":"en","@value":"The Institute of Electrical Engineers of Japan"},{"@language":"ja","@value":"一般社団法人 電気学会"}],"prism:publicationDate":"2001","prism:volume":"121","prism:number":"9","prism:startingPage":"1130","prism:endingPage":"1138"},"reviewed":"false","dcterms:accessRights":"http://purl.org/coar/access_right/c_abf2","url":[{"@id":"http://id.ndl.go.jp/bib/5894307"},{"@id":"https://ndlsearch.ndl.go.jp/books/R000000004-I5894307"},{"@id":"https://www.jstage.jst.go.jp/article/ieejpes1990/121/9/121_9_1130/_pdf"}],"availableAt":"2001","foaf:topic":[{"@id":"https://cir.nii.ac.jp/all?q=%E7%9B%B4%E6%B5%81%E9%80%81%E9%9B%BB","dc:title":"直流送電"},{"@id":"https://cir.nii.ac.jp/all?q=%E3%83%80%E3%82%A4%E3%82%AA%E3%83%BC%E3%83%89%E5%A4%89%E6%8F%9B%E5%99%A8","dc:title":"ダイオード変換器"},{"@id":"https://cir.nii.ac.jp/all?q=%E8%87%AA%E3%83%BB%E4%BB%96%E5%8A%B1%E5%BC%8F%E5%A4%89%E6%8F%9B%E5%99%A8%E3%83%8F%E3%82%A4%E3%83%96%E3%83%AA%E3%83%83%E3%83%89%E6%96%B9%E5%BC%8F","dc:title":"自・他励式変換器ハイブリッド方式"},{"@id":"https://cir.nii.ac.jp/all?q=%E8%87%AA%E5%8A%B1%E5%BC%8F%E5%A4%89%E6%8F%9B%E5%99%A8","dc:title":"自励式変換器"}],"relatedProduct":[{"@id":"https://cir.nii.ac.jp/crid/1361699994553728256","@type":"Article","relationType":["cites"],"jpcoar:relatedTitle":[{"@value":"Development and testing of prototype models for a high-performance 300 MW self-commutated AC/DC converter"}]},{"@id":"https://cir.nii.ac.jp/crid/1570572699519433728","@type":"Article","relationType":["cites"],"jpcoar:relatedTitle":[{"@language":"en","@value":"Control and Protection Systems for DC Transmission System with Diode Valve Converter"}]},{"@id":"https://cir.nii.ac.jp/crid/1570854174496145408","@type":"Article","relationType":["cites"]},{"@id":"https://cir.nii.ac.jp/crid/1570854174496146560","@type":"Article","relationType":["cites"],"jpcoar:relatedTitle":[{"@value":"高性能交直変換器の開発"}]},{"@id":"https://cir.nii.ac.jp/crid/1570854174496147840","@type":"Article","relationType":["cites"],"jpcoar:relatedTitle":[{"@value":"ハイブリッド直流多端子送電制御保護方式の基本性能検証"}]},{"@id":"https://cir.nii.ac.jp/crid/1570854174496150272","@type":"Article","relationType":["cites"],"jpcoar:relatedTitle":[{"@value":"高性能交直変換器用制御システムの開発"}]},{"@id":"https://cir.nii.ac.jp/crid/1571417126631772288","@type":"Article","relationType":["cites"],"jpcoar:relatedTitle":[{"@language":"en","@value":"A Diode Rectifier Series Tap on an HVDC Line"}]},{"@id":"https://cir.nii.ac.jp/crid/1571698599426277632","@type":"Article","relationType":["cites"],"jpcoar:relatedTitle":[{"@language":"en","@value":"First Benchmark Model for HVDC Control Studies"}]},{"@id":"https://cir.nii.ac.jp/crid/1571980074402988928","@type":"Article","relationType":["cites"],"jpcoar:relatedTitle":[{"@value":"HVDC用順変換所におけるダイオード変換器とサイリスタ変換器の直列接続"}]},{"@id":"https://cir.nii.ac.jp/crid/1572543024356412672","@type":"Article","relationType":["cites"],"jpcoar:relatedTitle":[{"@language":"en","@value":"Guide for Preliminary Design and Specification of Hydro Stations with HVDC Unit Connected Generators"}]},{"@id":"https://cir.nii.ac.jp/crid/1572543025249549696","@type":"Article","relationType":["isCitedBy"],"jpcoar:relatedTitle":[{"@language":"ja","@value":"直流送電用自・他励式直列接続逆変換所に関する基礎検討"},{"@language":"en","@value":"Series Connection of Line Commutated Converters and Voltage Sourced Converters in an HVDC Inverter Station"}]},{"@id":"https://cir.nii.ac.jp/crid/1573668924263253632","@type":"Article","relationType":["cites"],"jpcoar:relatedTitle":[{"@value":"高電圧サイリスタバルブの試験法"}]}],"dataSourceIdentifier":[{"@type":"JALC","@value":"oai:japanlinkcenter.org:2002179328"},{"@type":"NDL_SEARCH","@value":"oai:ndlsearch.ndl.go.jp:R000000004-I5894307"},{"@type":"CROSSREF","@value":"10.1541/ieejpes1990.121.9_1130"},{"@type":"CIA","@value":"10006759121"},{"@type":"CIA","@value":"130006841042"},{"@type":"OPENAIRE","@value":"doi_dedup___::7cdff6d12d1dbf48e94d866031285739"}]}