{"@context":{"@vocab":"https://cir.nii.ac.jp/schema/1.0/","rdfs":"http://www.w3.org/2000/01/rdf-schema#","dc":"http://purl.org/dc/elements/1.1/","dcterms":"http://purl.org/dc/terms/","foaf":"http://xmlns.com/foaf/0.1/","prism":"http://prismstandard.org/namespaces/basic/2.0/","cinii":"http://ci.nii.ac.jp/ns/1.0/","datacite":"https://schema.datacite.org/meta/kernel-4/","ndl":"http://ndl.go.jp/dcndl/terms/","jpcoar":"https://github.com/JPCOAR/schema/blob/master/2.0/"},"@id":"https://cir.nii.ac.jp/crid/1390282679581453312.json","@type":"Article","productIdentifier":[{"identifier":{"@type":"DOI","@value":"10.1541/ieejpes1990.117.7_1039"}},{"identifier":{"@type":"NDL_BIB_ID","@value":"4248125"}},{"identifier":{"@type":"URI","@value":"http://id.ndl.go.jp/bib/4248125"}},{"identifier":{"@type":"URI","@value":"https://ndlsearch.ndl.go.jp/books/R000000004-I4248125"}},{"identifier":{"@type":"URI","@value":"https://www.jstage.jst.go.jp/article/ieejpes1990/117/7/117_7_1039/_pdf"}},{"identifier":{"@type":"NAID","@value":"130006841223"}},{"identifier":{"@type":"NAID","@value":"10016960952"}},{"identifier":{"@type":"NAID","@value":"10009876125"}}],"dc:title":[{"@language":"ja","@value":"発変電所における低圧制御回路に発生する過電圧の実験的検討"},{"@language":"en","@value":"Expertimental Study of Overvoltages in Low-Voltage Control Circuit of Power Stations and Substations"},{"@language":"ja-Kana","@value":"ハツヘンデンショ ニ オケル テイアツ セイギョ カイロ ニ ハッセイスル カ"}],"description":[{"type":"abstract","notation":[{"@language":"en","@value":"Low-voltage control circuits of power stations and substations have a very important role to maintain the high quality and reliability of electric power systems. Digital circuits are widely used in the low-voltage control circuits by introducing integrated circuits. Operation voltages and the insulation level of the control circuits are much smaller than power-frequency voltages and the insulation level of the main circuits. Thus, faults and troubles in the control circuits increase nevertheless those in the main circuits decrease.<br> A study on the control circuits is focused on the effective and accurate operation of the power systems by the use of the control circuits. The insulation design of the control circuits, however, has not been investigated satisfactorily. Then, this paper presents measured overvoltages in a low-voltage control circuit model consisting of a control cable and control pannels installed on a grounding net for a lightning impulse voltage being applied on a main circuit consisting of a surge arrester and a potential divider."}],"abstractLicenseFlag":"disallow"}],"creator":[{"@id":"https://cir.nii.ac.jp/crid/1410282679580760833","@type":"Researcher","personIdentifier":[{"@type":"NRID","@value":"9000000006637"},{"@type":"NRID","@value":"9000391533012"},{"@type":"NRID","@value":"9000391534237"},{"@type":"NRID","@value":"9000391535347"}],"foaf:name":[{"@language":"ja","@value":"林田 弘"},{"@language":"en","@value":"Hayashida Hiroshi"}],"jpcoar:affiliationName":[{"@language":"en","@value":"Kansai Electric Power Co., Inc."},{"@language":"ja","@value":"関西電力"}]},{"@id":"https://cir.nii.ac.jp/crid/1410282679581453316","@type":"Researcher","personIdentifier":[{"@type":"NRID","@value":"9000000899396"},{"@type":"NRID","@value":"9000391535348"}],"foaf:name":[{"@language":"ja","@value":"中釜 義昭"},{"@language":"en","@value":"Nakagama Yoshiaki"}],"jpcoar:affiliationName":[{"@language":"en","@value":"Kansai Electric Power Co., Inc."},{"@language":"ja","@value":"関西電力"}]},{"@id":"https://cir.nii.ac.jp/crid/1410001204603698052","@type":"Researcher","personIdentifier":[{"@type":"NRID","@value":"9000000177421"},{"@type":"NRID","@value":"9000391535349"},{"@type":"NRID","@value":"9000391532316"}],"foaf:name":[{"@language":"ja","@value":"福園 秀伸"},{"@language":"en","@value":"Fukuzono Hidenobu"}],"jpcoar:affiliationName":[{"@language":"en","@value":"Kansai Tech Corp."},{"@language":"ja","@value":"関西テック"}]},{"@id":"https://cir.nii.ac.jp/crid/1410282679581453312","@type":"Researcher","personIdentifier":[{"@type":"NRID","@value":"9000000898890"},{"@type":"NRID","@value":"9000391538095"},{"@type":"NRID","@value":"9000391535350"}],"foaf:name":[{"@language":"ja","@value":"豊田 章"},{"@language":"en","@value":"Toyota Akira"}],"jpcoar:affiliationName":[{"@language":"en","@value":"Kansai Tech Corp."},{"@language":"ja","@value":"関西テック"}]},{"@id":"https://cir.nii.ac.jp/crid/1410001204601693056","@type":"Researcher","personIdentifier":[{"@type":"NRID","@value":"9000000006243"},{"@type":"NRID","@value":"9000391539137"},{"@type":"NRID","@value":"9000391532297"},{"@type":"NRID","@value":"9000391539049"},{"@type":"NRID","@value":"9000415158671"}],"foaf:name":[{"@language":"ja","@value":"関岡 昇三"},{"@language":"en","@value":"Sekioka Shozo"}],"jpcoar:affiliationName":[{"@language":"en","@value":"Kansai Tech Corp."},{"@language":"ja","@value":"関西テック"}]}],"publication":{"publicationIdentifier":[{"@type":"PISSN","@value":"03854213"},{"@type":"LISSN","@value":"03854213"},{"@type":"EISSN","@value":"13488147"},{"@type":"NDL_BIB_ID","@value":"000000015706"},{"@type":"ISSN","@value":"03854213"},{"@type":"NCID","@value":"AN10136334"}],"prism:publicationName":[{"@language":"en","@value":"IEEJ Transactions on Power and Energy"},{"@language":"ja","@value":"電気学会論文誌Ｂ（電力・エネルギー部門誌）"},{"@language":"ja","@value":"電気学会論文誌．　Ｂ"},{"@value":"電気学会論文誌. B"},{"@language":"en","@value":"IEEJ Trans. PE"},{"@language":"ja","@value":"電学論Ｂ"},{"@language":"en","@value":"IEEJ Trans.PE"},{"@language":"ja","@value":"電気学会論文誌．　Ｂ"}],"dc:publisher":[{"@language":"en","@value":"The Institute of Electrical Engineers of Japan"},{"@language":"ja","@value":"一般社団法人 電気学会"}],"prism:publicationDate":"1997","prism:volume":"117","prism:number":"7","prism:startingPage":"1039","prism:endingPage":"1049"},"reviewed":"false","url":[{"@id":"http://id.ndl.go.jp/bib/4248125"},{"@id":"https://ndlsearch.ndl.go.jp/books/R000000004-I4248125"},{"@id":"https://www.jstage.jst.go.jp/article/ieejpes1990/117/7/117_7_1039/_pdf"}],"availableAt":"1997","foaf:topic":[{"@id":"https://cir.nii.ac.jp/all?q=%E4%BD%8E%E5%9C%A7%E5%88%B6%E5%BE%A1%E5%9B%9E%E8%B7%AF","dc:title":"低圧制御回路"},{"@id":"https://cir.nii.ac.jp/all?q=%E9%81%BF%E9%9B%B7%E5%99%A8","dc:title":"避雷器"},{"@id":"https://cir.nii.ac.jp/all?q=%E5%88%B6%E5%BE%A1%E3%82%B1%E3%83%BC%E3%83%96%E3%83%AB","dc:title":"制御ケーブル"},{"@id":"https://cir.nii.ac.jp/all?q=%E8%80%90%E9%9B%B7%E8%A8%AD%E8%A8%88","dc:title":"耐雷設計"}],"relatedProduct":[{"@id":"https://cir.nii.ac.jp/crid/1390282679579661440","@type":"Article","relationType":["isReferencedBy","isCitedBy"],"jpcoar:relatedTitle":[{"@language":"en","@value":"Study on Measure to the Reduction of the Surge Voltage on Low Voltage Circuit in Substation"},{"@language":"ja","@value":"変電所低圧制御回路に発生するサージ電圧低減対策の検討"},{"@language":"ja-Kana","@value":"ヘンデンショ テイアツ セイギョ カイロ ニ ハッセイスル サージ デンアツ テイゲン タイサク ノ ケントウ"}]},{"@id":"https://cir.nii.ac.jp/crid/1570009749813085824","@type":"Article","relationType":["cites"],"jpcoar:relatedTitle":[{"@value":"77kV変電所侵入雷サージの測定"}]},{"@id":"https://cir.nii.ac.jp/crid/1570291224789795712","@type":"Article","relationType":["cites"],"jpcoar:relatedTitle":[{"@value":"全天候型分割可搬式インパルス電圧発生装置の開発と接地抵抗非線形特性試験への適用"}]},{"@id":"https://cir.nii.ac.jp/crid/1570291226528507904","@type":"Article","relationType":["cites"],"jpcoar:relatedTitle":[{"@value":"低圧制御回路絶縁設計"}]},{"@id":"https://cir.nii.ac.jp/crid/1570854176706325120","@type":"Article","relationType":["cites"],"jpcoar:relatedTitle":[{"@language":"en","@value":"Effects of the metal sheathed cables upon the performances of the distribution substations grounding systems"}]},{"@id":"https://cir.nii.ac.jp/crid/1570854176722436352","@type":"Article","relationType":["cites"],"jpcoar:relatedTitle":[{"@value":"変電所接地網大電流特性が雷サージ解析に与える影響"}]},{"@id":"https://cir.nii.ac.jp/crid/1571135651159173632","@type":"Article","relationType":["isCitedBy"],"jpcoar:relatedTitle":[{"@language":"en","@value":"A Study on Induced Surge voltages on a Control Cable by a Lightning Current Flowing into a Grounding Grid"}]},{"@id":"https://cir.nii.ac.jp/crid/1571698599673353856","@type":"Article","relationType":["cites"],"jpcoar:relatedTitle":[{"@value":"発変電所における低圧制御回路の雷害実態調査結果の分析"}]},{"@id":"https://cir.nii.ac.jp/crid/1571980074650058752","@type":"Article","relationType":["cites"],"jpcoar:relatedTitle":[{"@value":"発変電所耐雷設計基準要綱"}]},{"@id":"https://cir.nii.ac.jp/crid/1571980074650062080","@type":"Article","relationType":["cites"],"jpcoar:relatedTitle":[{"@value":"低圧制御回路のサージに関する実験的検討"}]},{"@id":"https://cir.nii.ac.jp/crid/1571980074650063232","@type":"Article","relationType":["cites"]},{"@id":"https://cir.nii.ac.jp/crid/1572261548969870976","@type":"Article","relationType":["cites"],"jpcoar:relatedTitle":[{"@value":"酸化亜鉛形避雷器の特性と評価試験法"}]},{"@id":"https://cir.nii.ac.jp/crid/1572261550184603136","@type":"Article","relationType":["isCitedBy"],"jpcoar:relatedTitle":[{"@language":"ja","@value":"FDTD法による埋設地線から制御線への誘導電圧計算の一検討"},{"@language":"en","@value":"A Simulation Study of voltages on an aerial wire induced by a current through a conterpoise using the FDTD method"}]},{"@id":"https://cir.nii.ac.jp/crid/1572543026566588544","@type":"Article","relationType":["cites"],"jpcoar:relatedTitle":[{"@language":"en","@value":"The effect of surges on electronic appliances"}]},{"@id":"https://cir.nii.ac.jp/crid/1572824499580193536","@type":"Article","relationType":["cites"],"jpcoar:relatedTitle":[{"@value":"電力系統運用のインテリジェント化"}]},{"@id":"https://cir.nii.ac.jp/crid/1572824499580195712","@type":"Article","relationType":["cites"],"jpcoar:relatedTitle":[{"@value":"発変電所および地中送電線の耐雷設計ガイド"}]},{"@id":"https://cir.nii.ac.jp/crid/1572824499580197632","@type":"Article","relationType":["cites"],"jpcoar:relatedTitle":[{"@value":"77kV変電所接地網インピーダンスのインパルス大電流特性"}]},{"@id":"https://cir.nii.ac.jp/crid/1573387448876714624","@type":"Article","relationType":["cites"],"jpcoar:relatedTitle":[{"@value":"過渡現象解析プログラムEMTPの最近の動向"}]},{"@id":"https://cir.nii.ac.jp/crid/1573387450978476672","@type":"Article","relationType":["cites"],"jpcoar:relatedTitle":[{"@language":"en","@value":"Magnitude and frequency of transient induced voltages in low-voltage control circuits of power stations and substations"}]},{"@id":"https://cir.nii.ac.jp/crid/1573668923853427584","@type":"Article","relationType":["cites"]},{"@id":"https://cir.nii.ac.jp/crid/1573668924510321280","@type":"Article","relationType":["cites"],"jpcoar:relatedTitle":[{"@value":"低圧制御回路絶縁試験法 試験電圧標準"}]},{"@id":"https://cir.nii.ac.jp/crid/1573950399487035520","@type":"Article","relationType":["cites"],"jpcoar:relatedTitle":[{"@value":"汎用過渡現象解析プログラムにおけるフラッシオーバ特性計算"}]},{"@id":"https://cir.nii.ac.jp/crid/1574231873958294016","@type":"Article","relationType":["cites"],"jpcoar:relatedTitle":[{"@value":"2相回路モデルによる雷サージ解析"}]}],"dataSourceIdentifier":[{"@type":"JALC","@value":"oai:japanlinkcenter.org:2002178386"},{"@type":"NDL_SEARCH","@value":"oai:ndlsearch.ndl.go.jp:R000000004-I4248125"},{"@type":"CROSSREF","@value":"10.1541/ieejpes1990.117.7_1039"},{"@type":"CIA","@value":"10009876125"},{"@type":"CIA","@value":"130006841223"},{"@type":"CIA","@value":"10016960952"},{"@type":"CROSSREF","@value":"10.1541/ieejpes.129.191_references_DOI_KEPisDWw3fjJyhdY2T1SY7Kvf3G"}]}