7万kW級超電導発電機の電力系統における同期調相機運転試験

DOI DOI Web Site Web Site Web Site ほか1件をすべて表示 一部だけ表示 被引用文献1件 参考文献16件 オープンアクセス

書誌事項

タイトル別名
  • Field Test of 70MW Class Superconducting Generator in The Mode of Synchronous Condenser
  • 7マンkWキュウ チョウデンドウハツデンキ ノ デンリョク ケイトウ ニ オケル ドウキチョウソウキ ウンテン シケン
  • Field test of a 70‐MW‐class superconducting generator in the mode of a synchronous condenser

この論文をさがす

説明

In order to study the basic performance of the superconducting generator in the actual electric power system, the quick response excitation type generator was connected to 77kV commercial power grid of the KANSAI Electric Power Co., Inc. In the test, the model machine was operated as a rotary condenser supplying about leading 40MV ar to the electric power system. In the tests, the model machine operated stably. The results show that the superconductig generator has effects for stabilizing voltage fluctuations of electric power system and also for reducing shunt reactor.