{"@context":{"@vocab":"https://cir.nii.ac.jp/schema/1.0/","rdfs":"http://www.w3.org/2000/01/rdf-schema#","dc":"http://purl.org/dc/elements/1.1/","dcterms":"http://purl.org/dc/terms/","foaf":"http://xmlns.com/foaf/0.1/","prism":"http://prismstandard.org/namespaces/basic/2.0/","cinii":"http://ci.nii.ac.jp/ns/1.0/","datacite":"https://schema.datacite.org/meta/kernel-4/","ndl":"http://ndl.go.jp/dcndl/terms/","jpcoar":"https://github.com/JPCOAR/schema/blob/master/2.0/"},"@id":"https://cir.nii.ac.jp/crid/1390282679632709248.json","@type":"Article","productIdentifier":[{"identifier":{"@type":"DOI","@value":"10.7130/hokkaidoshakai.29.372"}},{"identifier":{"@type":"NAID","@value":"10013926214"}},{"identifier":{"@type":"URI","@value":"https://search.jamas.or.jp/link/ui/2003149806"}}],"dc:title":[{"@value":"静脈リザーバーの各種性能評価"}],"dc:language":"ja","description":[{"type":"abstract","notation":[{"@value":"【要旨】現在当院で使用している静脈リザーバー(VR)を用いて,これらが持っている特徴を実験的に検証し若干の知見を得たので報告する。3種類のVR(E-VR,C-VR,L-VR)それぞれに人工心肺模擬回路を用いて実験を行った。実験に用いた灌流液は,6Lの牛血を用い,灌流量4L/min,温度ガスコントロール行った後,実験を行った。実験は,VRの撹拌能力とバブルトラップ能力について検討した。その結果,実験1:E-VRとL-VRは,5分以内ですべての各静脈レベルで同等のHct値になり撹絆は良好であった,C-VRは5分経過後も撹拌遅延した。実験2:E-VRとL-VRは,CRポートから注入するも各静脈レベルでのHctの変化はなく撹拌は良好であった。C-VRは,上澄みが分離しVR内の撹拌がされにくかった。実験3:E-VRとC-VRは,空気混入が少なく,L-VRは,エアー注入後明らかに変化が見られた。E-VRは各実験とも良好な結果が得られた。LVRとC-VRは撹拌能力とエアートラップ能力は相反する現象が得られた。人工肺の特徴と同様,静脈リザーバーの特徴を把握することが重要であり,安全性を高める上で必要不可欠である。Key words: 静脈リザーバー,撹拌能力,エアートラップ能力"}],"abstractLicenseFlag":"disallow"}],"creator":[{"@id":"https://cir.nii.ac.jp/crid/1410001204655439746","@type":"Researcher","personIdentifier":[{"@type":"NRID","@value":"9000017287862"},{"@type":"NRID","@value":"9000254375638"},{"@type":"NRID","@value":"9000254375412"},{"@type":"NRID","@value":"9000254376251"}],"foaf:name":[{"@language":"ja","@value":"山崎 隆文"}],"jpcoar:affiliationName":[{"@language":"ja","@value":"亀田総合病院ME室"}]},{"@id":"https://cir.nii.ac.jp/crid/1410009221357880192","@type":"Researcher","personIdentifier":[{"@type":"NRID","@value":"9000001376174"},{"@type":"NRID","@value":"9000254376254"}],"foaf:name":[{"@language":"ja","@value":"菱沼 浩孝"}],"jpcoar:affiliationName":[{"@language":"ja","@value":"亀田総合病院ME室"}]},{"@id":"https://cir.nii.ac.jp/crid/1410001204656174209","@type":"Researcher","personIdentifier":[{"@type":"NRID","@value":"9000001376272"}],"foaf:name":[{"@language":"ja","@value":"齊藤 建"}],"jpcoar:affiliationName":[{"@language":"ja","@value":"亀田総合病院ME室"}]},{"@id":"https://cir.nii.ac.jp/crid/1410282679631148418","@type":"Researcher","personIdentifier":[{"@type":"NRID","@value":"9000005790321"},{"@type":"NRID","@value":"9000254375644"},{"@type":"NRID","@value":"9000254375415"}],"foaf:name":[{"@language":"ja","@value":"河瀬 勇"}],"jpcoar:affiliationName":[{"@language":"ja","@value":"亀田総合病院心臓血管外科"}]},{"@id":"https://cir.nii.ac.jp/crid/1410001204656916230","@type":"Researcher","personIdentifier":[{"@type":"NRID","@value":"9000003499299"},{"@type":"NRID","@value":"9000254375642"},{"@type":"NRID","@value":"9000254375413"},{"@type":"NRID","@value":"9000254376256"},{"@type":"NRID","@value":"9000253457535"}],"foaf:name":[{"@language":"ja","@value":"外山 雅章"}],"jpcoar:affiliationName":[{"@language":"ja","@value":"亀田総合病院心臓血管外科"}]}],"publication":{"publicationIdentifier":[{"@type":"PISSN","@value":"09122664"},{"@type":"EISSN","@value":"18845452"},{"@type":"NCID","@value":"AN1020635X"}],"prism:publicationName":[{"@language":"en","@value":"Japanese Journal of Extra-Corporeal Technology"},{"@value":"体外循環技術"},{"@language":"ja","@value":"体外循環技術"},{"@language":"en","@value":"JJECT"},{"@language":"ja","@value":"体外循環技術"},{"@language":"en","@value":"Japanese journal of extra-corporeal technology"}],"dc:publisher":[{"@language":"en","@value":"The Japanese Society of Extra-Corporeal Technology in Medicine"},{"@language":"ja","@value":"一般社団法人 日本体外循環技術医学会"}],"prism:publicationDate":"2002","prism:volume":"29","prism:number":"4","prism:startingPage":"372","prism:endingPage":"376"},"reviewed":"false","url":[{"@id":"https://search.jamas.or.jp/link/ui/2003149806"}],"availableAt":"2002","relatedProduct":[{"@id":"https://cir.nii.ac.jp/crid/1360292619723817984","@type":"Article","relationType":["cites"],"jpcoar:relatedTitle":[{"@value":"Air embolism during cardiopulmonary bypass"}]},{"@id":"https://cir.nii.ac.jp/crid/1390282679631586688","@type":"Article","relationType":["isCitedBy"],"jpcoar:relatedTitle":[{"@value":"可動式レベルセンサーの使用経験―レベルセンサーユニットＬＳｃ　ＩＩについて―"}]},{"@id":"https://cir.nii.ac.jp/crid/1390282679632780672","@type":"Article","relationType":["isCitedBy"],"jpcoar:relatedTitle":[{"@value":"小児用静脈貯血槽の各種性能評価―気泡捕捉能を中心に―"},{"@language":"en","@value":"Evaluation of venous reservoirs for infants"}]},{"@id":"https://cir.nii.ac.jp/crid/1390282679633299072","@type":"Article","relationType":["isCitedBy"],"jpcoar:relatedTitle":[{"@value":"遠心ポンプ送血におけるエアー混入時の安全対策"},{"@language":"en","@value":"In in vitro study, removal micro bubble occurring from circuit tubing using centrifugal type blood pump during extracorporeal circulation for safety."}]},{"@id":"https://cir.nii.ac.jp/crid/1390574181078860928","@type":"Article","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@language":"en","@value":"Evaluation of capability for drug diffusion in the hard-shell venous reservoir"},{"@language":"ja","@value":"ハードシェル静脈リザーバーにおける薬液拡散の性能評価"}]},{"@id":"https://cir.nii.ac.jp/crid/1570572699935009024","@type":"Article","relationType":["cites"],"jpcoar:relatedTitle":[{"@value":"ポンプシステムとモニタリングシステム"}]},{"@id":"https://cir.nii.ac.jp/crid/1572261551048862080","@type":"Article","relationType":["isCitedBy"],"jpcoar:relatedTitle":[{"@language":"ja","@value":"フィルター体型膜型人工肺のバブルトラップ特性の実験的検討"},{"@language":"en","@value":"In order to evaluate the air bubble trapping characteristics of a micro-porous membrane oxygenator with a built-in arterial filter"}]},{"@id":"https://cir.nii.ac.jp/crid/1572824499748693632","@type":"Article","relationType":["cites"],"jpcoar:relatedTitle":[{"@language":"en","@value":"Assisted venous drainage, venous air and gaseous microemboli transmission into the arterial line ; An in-vitro Study"}]},{"@id":"https://cir.nii.ac.jp/crid/1572824499748696192","@type":"Article","relationType":["cites"],"jpcoar:relatedTitle":[{"@value":"遠心ポンプ脱血法におる静脈空気混入が及ぼす危険性について"}]},{"@id":"https://cir.nii.ac.jp/crid/1573387449702115456","@type":"Article","relationType":["cites"],"jpcoar:relatedTitle":[{"@value":"体外循環動脈ライン用バブルトラップの安全性と有効性について"}]},{"@id":"https://cir.nii.ac.jp/crid/1573668924678826112","@type":"Article","relationType":["cites"],"jpcoar:relatedTitle":[{"@value":"膜型人工肺が有する Bubble Trap Performance の測定"}]},{"@id":"https://cir.nii.ac.jp/crid/1573668924678827264","@type":"Article","relationType":["cites"],"jpcoar:relatedTitle":[{"@value":"完全閉鎖型人工心肺回路の臨床応用"}]},{"@id":"https://cir.nii.ac.jp/crid/1573668925932397056","@type":"Article","relationType":["isCitedBy"],"jpcoar:relatedTitle":[{"@language":"ja","@value":"静脈血リザーバーの性能試験に関する実験的検討"},{"@language":"en","@value":"Experimental study on performance testing of venous reservoir"}]},{"@id":"https://cir.nii.ac.jp/crid/1573950399752698112","@type":"Article","relationType":["isCitedBy"],"jpcoar:relatedTitle":[{"@language":"ja","@value":"ハードシェルタイプ静脈リザーバーの検討"},{"@language":"en","@value":"Examination of hard shell type venous reservoir"}]}],"dataSourceIdentifier":[{"@type":"JALC","@value":"oai:japanlinkcenter.org:0016303253"},{"@type":"CROSSREF","@value":"10.7130/hokkaidoshakai.29.372"},{"@type":"CIA","@value":"10013926214"},{"@type":"CROSSREF","@value":"10.7130/jject.49.87_references_DOI_J8cSN1Tajeh2rkh8xvtW6KYU6Yq"}]}