{"@context":{"@vocab":"https://cir.nii.ac.jp/schema/1.0/","rdfs":"http://www.w3.org/2000/01/rdf-schema#","dc":"http://purl.org/dc/elements/1.1/","dcterms":"http://purl.org/dc/terms/","foaf":"http://xmlns.com/foaf/0.1/","prism":"http://prismstandard.org/namespaces/basic/2.0/","cinii":"http://ci.nii.ac.jp/ns/1.0/","datacite":"https://schema.datacite.org/meta/kernel-4/","ndl":"http://ndl.go.jp/dcndl/terms/","jpcoar":"https://github.com/JPCOAR/schema/blob/master/2.0/"},"@id":"https://cir.nii.ac.jp/crid/1390282679694670592.json","@type":"Article","productIdentifier":[{"identifier":{"@type":"DOI","@value":"10.4012/dmj.2013-284"}},{"identifier":{"@type":"COI","@value":"1:STN:280:DC%2BC2cfpt1GltQ%3D%3D"}},{"identifier":{"@type":"PMID","@value":"24988882"}},{"identifier":{"@type":"URI","@value":"https://www.jstage.jst.go.jp/article/dmj/33/4/33_2013-284/_pdf"}},{"identifier":{"@type":"NAID","@value":"130004679317"}},{"identifier":{"@type":"URI","@value":"https://search.jamas.or.jp/link/ui/2015176102"}}],"resourceType":"学術雑誌論文(journal article)","dc:title":[{"@language":"en","@value":"Fit of zirconia all-ceramic crowns with different cervical margin designs, before and after porcelain firing and glazing"}],"dc:language":"en","description":[{"type":"abstract","notation":[{"@language":"en","@value":"The purpose of this study is to investigate the fit of zirconia cores and all-ceramic crowns prepared with different cervical margin designs. The radius of curvature between the axial wall and the occlusal surface was set to 1 mm in an abutment using the cervical shoulder marginal design (S) and to 0.2 and 0.5 mm in abutments with round shoulders (0.2RS and 0.5RS, respectively). The internal gaps of the cores were 45–138 μm (S), 41–141 μm (0.2RS), and 43–133 μm (0.5RS). The internal gaps of the all-ceramic crowns were 40–115 μm (S), 45–113 μm (0.2RS), and 42–126 μm (0.5RS). There were no significant differences in one-way ANOVA for any region in any marginal design before and after firing the porcelain. The marginal gaps between the all-ceramic crowns and dies were 27±25 (S), 30±29 (0.2RS), and 24±27 μm (0.5RS), again with no significant differences in one-way ANOVA."}],"abstractLicenseFlag":"disallow"}],"creator":[{"@id":"https://cir.nii.ac.jp/crid/1420282801188467456","@type":"Researcher","personIdentifier":[{"@type":"KAKEN_RESEARCHERS","@value":"60431590"},{"@type":"NRID","@value":"1000060431590"},{"@type":"NRID","@value":"9000398587209"},{"@type":"NRID","@value":"9000408919380"},{"@type":"NRID","@value":"9000408455017"},{"@type":"NRID","@value":"9000411222571"},{"@type":"NRID","@value":"9000345224026"},{"@type":"NRID","@value":"9000402772075"},{"@type":"NRID","@value":"9000259839963"},{"@type":"NRID","@value":"9000415155443"},{"@type":"NRID","@value":"9000413249457"},{"@type":"NRID","@value":"9000412544217"},{"@type":"NRID","@value":"9000402937211"},{"@type":"NRID","@value":"9000412657723"},{"@type":"NRID","@value":"9000415181818"},{"@type":"NRID","@value":"9000259839437"},{"@type":"NRID","@value":"9000399810279"},{"@type":"RESEARCHMAP","@value":"https://researchmap.jp/shokomiura"}],"foaf:name":[{"@language":"en","@value":"MIURA Shoko"}],"jpcoar:affiliationName":[{"@language":"en","@value":"Department of Restorative Dentistry, Division of Fixed Prosthodontics, Tohoku University Graduate School of Dentistry"}]},{"@id":"https://cir.nii.ac.jp/crid/1420845751163742208","@type":"Researcher","personIdentifier":[{"@type":"KAKEN_RESEARCHERS","@value":"60260444"},{"@type":"NRID","@value":"1000060260444"},{"@type":"NRID","@value":"9000002510798"},{"@type":"NRID","@value":"9000261036342"},{"@type":"NRID","@value":"9000307262114"},{"@type":"NRID","@value":"9000000706962"},{"@type":"NRID","@value":"9000238225012"},{"@type":"NRID","@value":"9000023610195"},{"@type":"NRID","@value":"9000391818009"},{"@type":"NRID","@value":"9000259839438"},{"@type":"RESEARCHMAP","@value":"https://researchmap.jp/read0184513"}],"foaf:name":[{"@language":"en","@value":"INAGAKI Ryoichi"}],"jpcoar:affiliationName":[{"@language":"en","@value":"Department of Restorative Dentistry, Division of Fixed Prosthodontics, Tohoku University Graduate School of Dentistry"}]},{"@id":"https://cir.nii.ac.jp/crid/1030003658416690176","@type":"Researcher","personIdentifier":[{"@type":"KAKEN_RESEARCHERS","@value":"70169407"},{"@type":"NRID","@value":"1000070169407"},{"@type":"NRID","@value":"9000259839966"},{"@type":"NRID","@value":"9000259839439"}],"foaf:name":[{"@language":"en","@value":"KASAHARA Shin"}],"jpcoar:affiliationName":[{"@language":"en","@value":"Department of Restorative Dentistry, Division of Fixed Prosthodontics, Tohoku University Graduate School of Dentistry"}]},{"@id":"https://cir.nii.ac.jp/crid/1030003658503907205","@type":"Researcher","personIdentifier":[{"@type":"KAKEN_RESEARCHERS","@value":"70005073"},{"@type":"NRID","@value":"1000070005073"},{"@type":"NRID","@value":"9000398584966"},{"@type":"NRID","@value":"9000020311166"},{"@type":"NRID","@value":"9000020341355"},{"@type":"NRID","@value":"9000005484518"},{"@type":"NRID","@value":"9000021344864"},{"@type":"NRID","@value":"9000014548833"},{"@type":"NRID","@value":"9000391820974"},{"@type":"NRID","@value":"9000391821329"},{"@type":"NRID","@value":"9000398584240"},{"@type":"NRID","@value":"9000391824468"},{"@type":"NRID","@value":"9000391820790"},{"@type":"NRID","@value":"9000259839968"},{"@type":"NRID","@value":"9000006681535"},{"@type":"NRID","@value":"9000391829817"},{"@type":"NRID","@value":"9000398586534"},{"@type":"NRID","@value":"9000398586376"},{"@type":"NRID","@value":"9000398585919"},{"@type":"NRID","@value":"9000391817461"},{"@type":"NRID","@value":"9000398586934"},{"@type":"NRID","@value":"9000398586765"},{"@type":"NRID","@value":"9000391826737"},{"@type":"NRID","@value":"9000398587677"},{"@type":"NRID","@value":"9000398587693"},{"@type":"NRID","@value":"9000398587212"},{"@type":"NRID","@value":"9000398587776"},{"@type":"NRID","@value":"9000020469321"},{"@type":"NRID","@value":"9000391822621"},{"@type":"NRID","@value":"9000398587527"},{"@type":"NRID","@value":"9000391827097"},{"@type":"NRID","@value":"9000391823971"},{"@type":"NRID","@value":"9000398586521"},{"@type":"NRID","@value":"9000398585378"},{"@type":"NRID","@value":"9000023610204"},{"@type":"NRID","@value":"9000391818011"},{"@type":"NRID","@value":"9000259839440"},{"@type":"NRID","@value":"9000020543357"},{"@type":"NRID","@value":"9000391817796"},{"@type":"NRID","@value":"9000391818530"},{"@type":"RESEARCHMAP","@value":"https://researchmap.jp/read0168602"}],"foaf:name":[{"@language":"en","@value":"YODA Masanobu"}],"jpcoar:affiliationName":[{"@language":"en","@value":"Department of Restorative Dentistry, Division of Fixed Prosthodontics, Tohoku University Graduate School of Dentistry"}]}],"publication":{"publicationIdentifier":[{"@type":"PISSN","@value":"02874547"},{"@type":"LISSN","@value":"02874547"},{"@type":"EISSN","@value":"18811361"}],"prism:publicationName":[{"@language":"en","@value":"Dental Materials Journal"},{"@language":"en","@value":"Dent. Mater. J."},{"@language":"en","@value":"Dental Materials Journal"}],"dc:publisher":[{"@language":"en","@value":"The Japanese Society for Dental Materials and Devices"},{"@language":"ja","@value":"一般社団法人　日本歯科理工学会"}],"prism:publicationDate":"2014","prism:volume":"33","prism:number":"4","prism:startingPage":"484","prism:endingPage":"489"},"reviewed":"false","dcterms:accessRights":"http://purl.org/coar/access_right/c_abf2","url":[{"@id":"https://www.jstage.jst.go.jp/article/dmj/33/4/33_2013-284/_pdf"},{"@id":"https://search.jamas.or.jp/link/ui/2015176102"}],"availableAt":"2014","foaf:topic":[{"@id":"https://cir.nii.ac.jp/all?q=Zirconia%20all-ceramic%20restoration","dc:title":"Zirconia all-ceramic restoration"},{"@id":"https://cir.nii.ac.jp/all?q=Y-TZP","dc:title":"Y-TZP"},{"@id":"https://cir.nii.ac.jp/all?q=CAD/CAM","dc:title":"CAD/CAM"},{"@id":"https://cir.nii.ac.jp/all?q=Adaptation","dc:title":"Adaptation"},{"@id":"https://cir.nii.ac.jp/all?q=Margin%20design","dc:title":"Margin design"}],"project":[{"@id":"https://cir.nii.ac.jp/crid/1040000782231709056","@type":"Project","projectIdentifier":[{"@type":"KAKEN","@value":"24792058"},{"@type":"JGN","@value":"JP24792058"},{"@type":"URI","@value":"https://kaken.nii.ac.jp/grant/KAKENHI-PROJECT-24792058/"}],"notation":[{"@language":"ja","@value":"ジルコニアオールセラミック修復用陶材の強度向上の要件を探る"},{"@language":"en","@value":"The factors to improve the strength of zirconia all-ceramic veneering porcelain."}]},{"@id":"https://cir.nii.ac.jp/crid/1040282257283150208","@type":"Project","projectIdentifier":[{"@type":"KAKEN","@value":"26462908"},{"@type":"JGN","@value":"JP26462908"},{"@type":"URI","@value":"https://kaken.nii.ac.jp/grant/KAKENHI-PROJECT-26462908/"}],"notation":[{"@language":"ja","@value":"フルカウントゥアジルコニア修復の長期予後を目指した前向き臨床研究"},{"@language":"en","@value":"Prospective clinical study aiming at long-term prognosis of full-contour zirconia restoration."}]}],"relatedProduct":[{"@id":"https://cir.nii.ac.jp/crid/1360002215337640448","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@value":"Clinical evaluation of zirconia-based all-ceramic single crowns: an up to 12-year retrospective cohort study"}]},{"@id":"https://cir.nii.ac.jp/crid/1360011144842790656","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Clinical marginal and internal gaps of In‐Ceram crowns fabricated using the GN‐I system"}]},{"@id":"https://cir.nii.ac.jp/crid/1360292618492115200","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Marginal and internal fit of all‐ceramic CAD/CAM crown‐copings on chamfer preparations"}]},{"@id":"https://cir.nii.ac.jp/crid/1360855570970820352","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Marginal Adaptation of Cerec 3 CAD/CAM Composite Crowns Using Two Different Finish Line Preparation Designs"}]},{"@id":"https://cir.nii.ac.jp/crid/1360855571170588928","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"The estimation of cement film thickness by an in vivo technique"}]},{"@id":"https://cir.nii.ac.jp/crid/1361137045707549312","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Clinical and research advancements in cast-gold restorations"}]},{"@id":"https://cir.nii.ac.jp/crid/1361137045759965184","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Non‐cast titanium restorations in fixed prosthodontics"}]},{"@id":"https://cir.nii.ac.jp/crid/1361418519411514880","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Evaluation of marginal fit of two allceramic copings with two finish lines"}]},{"@id":"https://cir.nii.ac.jp/crid/1361418521220753408","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Clinical marginal and internal gaps of Procera AllCeram crowns"}]},{"@id":"https://cir.nii.ac.jp/crid/1361699995827670400","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"The fit of gold inlays and three ceramic inlay systems: A clinical and in vitro study"}]},{"@id":"https://cir.nii.ac.jp/crid/1361699995947848448","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"The Effect of Different Fabrication Steps on the Marginal Adaptation of Two Types of Glass‐Infiltrated Ceramic Crown Copings Fabricated by CAD/CAM Technology"}]},{"@id":"https://cir.nii.ac.jp/crid/1361981469512455936","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"An In Vitro Evaluation of Fit of Zirconium‐Oxide‐Based Ceramic Four‐Unit Fixed Partial Dentures, Generated with Three Different CAD/CAM Systems, before and after Porcelain Firing Cycles and after Glaze Cycles"}]},{"@id":"https://cir.nii.ac.jp/crid/1361981470028521984","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Fit of metal ceramic crowns cast in Au-1.6 wt% Ti alloy for different abutment finish line curvature"}]},{"@id":"https://cir.nii.ac.jp/crid/1361981470160091520","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Adaptation of all-ceramic fixed partial dentures"}]},{"@id":"https://cir.nii.ac.jp/crid/1362544418592057344","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"In vitro marginal adaptation of alumina porcelain ceramic crowns"}]},{"@id":"https://cir.nii.ac.jp/crid/1362544419860865024","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"An investigation of dental luting cement solubility as a function of the marginal gap"}]},{"@id":"https://cir.nii.ac.jp/crid/1362825894213717632","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"The Clinical Success Of All-Ceramic Restorations"}]},{"@id":"https://cir.nii.ac.jp/crid/1362825894261490816","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Marginal fit of gold inlay castings"}]},{"@id":"https://cir.nii.ac.jp/crid/1363107368233409280","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Evaluation of the marginal accuracy of different all‐ceramic crown systems after simulation in the artificial mouth"}]},{"@id":"https://cir.nii.ac.jp/crid/1363388843516825088","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"The effect of cement thickness on the fracture strength of all‐ceramic crowns"}]},{"@id":"https://cir.nii.ac.jp/crid/1363388845454192000","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Influence of the veneering process on the marginal fit of zirconia fixed dental prostheses"}]},{"@id":"https://cir.nii.ac.jp/crid/1363388845690637952","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Comparison of the Marginal Adaptation of Zirconium Dioxide Crowns in Preparations with Two Different Finish Lines"}]},{"@id":"https://cir.nii.ac.jp/crid/1363670318900926080","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Clinical study of the internal gaps of zirconia and metal frameworks for fixed partial dentures"}]},{"@id":"https://cir.nii.ac.jp/crid/1363951794607305088","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Influence of firing cycles on the margin distortion of 3 all-ceramic crown systems"}]},{"@id":"https://cir.nii.ac.jp/crid/1363951794762909056","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Precision of fit: The Procera AllCeram crown"}]},{"@id":"https://cir.nii.ac.jp/crid/1364233268451606656","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Evaluation of marginal and internal fit of ceramic crown copings"}]},{"@id":"https://cir.nii.ac.jp/crid/1390001204715465728","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@language":"en","@value":"Marginal and Internal Adaptation of Zirconium Dioxide Ceramic Copings and Crowns with Different Finish Line Designs"}]},{"@id":"https://cir.nii.ac.jp/crid/1390001204716028416","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["references"],"jpcoar:relatedTitle":[{"@language":"en","@value":"Effect of Sintering on the Marginal and Internal Fit of CAD/CAM-fabricated Zirconia Frameworks"}]},{"@id":"https://cir.nii.ac.jp/crid/1390001204716768128","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["references"],"jpcoar:relatedTitle":[{"@language":"en","@value":"Durability of Tungsten Carbide Burs for the Fabrication of Titanium Crowns using Dental CAD/CAM"}]},{"@id":"https://cir.nii.ac.jp/crid/1390001204716932224","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["references"],"jpcoar:relatedTitle":[{"@language":"en","@value":"Radio-opacity of core materials for all-ceramic restorations"}]},{"@id":"https://cir.nii.ac.jp/crid/1390282679694647808","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@language":"en","@value":"SEM evaluation of the precision of fit of CAD/CAM zirconia and metal-ceramic posterior crowns"}]},{"@id":"https://cir.nii.ac.jp/crid/1390282680277552000","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@language":"en","@value":"A Basic Study on Fitness of All-ceramic Crown fabricated by CAD/CAM System"},{"@language":"ja","@value":"ＣＡＤ／ＣＡＭシステムで製作したオールセラミッククラウンの適合に関する基礎的研究"}]},{"@id":"https://cir.nii.ac.jp/crid/1390282680278465792","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@language":"ja","@value":"CAD/CAM冠の現状と将来展望"},{"@language":"en","@value":"Current status and future prospect of CAD/CAM composite crown"},{"@language":"ja-Kana","@value":"CAD/CAMカン ノ ゲンジョウ ト ショウライ テンボウ"}]},{"@id":"https://cir.nii.ac.jp/crid/1390294276466668160","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@language":"en","@value":"Comparison of the accuracy of resin-composite crowns fabricated by three-dimensional printing and milling methods"}]},{"@id":"https://cir.nii.ac.jp/crid/1390294949471373952","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@language":"en","@value":"Fracture strength and behavior of resin-faced CAD/CAM anterior crowns"}]},{"@id":"https://cir.nii.ac.jp/crid/1390850656304683520","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@language":"en","@value":"The effect of resin-coating technique on the bond strength between composite resin blocks for CAD/CAM and luting agents"}]},{"@id":"https://cir.nii.ac.jp/crid/1390855356034984064","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@language":"en","@value":"Effects of Cuspal Inclination and Luting Agent on Fracture Load Values in Composite Resin CAD/CAM Crowns"}]},{"@id":"https://cir.nii.ac.jp/crid/1390864713567322624","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@language":"en","@value":"The manufacturing characterization of zirconia core copings of CAD/CAM systems"}]},{"@id":"https://cir.nii.ac.jp/crid/1390869854627032192","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@language":"en","@value":"Effects of implant abutment CAD/CAM design parameters on subgingival remnant          cement"}]}],"dataSourceIdentifier":[{"@type":"JALC","@value":"oai:japanlinkcenter.org:1003786568"},{"@type":"CROSSREF","@value":"10.4012/dmj.2013-284"},{"@type":"PUBMED","@value":"24988882"},{"@type":"CIA","@value":"130004679317"},{"@type":"KAKEN","@value":"PRODUCT-14889356"},{"@type":"KAKEN","@value":"PRODUCT-15271016"},{"@type":"OPENAIRE","@value":"doi_dedup___::1ebdb9d97926a96aabd6ea0d0303a56a"},{"@type":"CROSSREF","@value":"10.1007/s00784-017-2142-y_references_DOI_W9w91X2lurMtHnpPRY6f9y1qmsU"},{"@type":"CROSSREF","@value":"10.2186/ajps.9.1_references_DOI_W9w91X2lurMtHnpPRY6f9y1qmsU"},{"@type":"CROSSREF","@value":"10.4012/dmj.2022-074_references_DOI_W9w91X2lurMtHnpPRY6f9y1qmsU"},{"@type":"CROSSREF","@value":"10.4012/dmj.2016-305_references_DOI_W9w91X2lurMtHnpPRY6f9y1qmsU"},{"@type":"CROSSREF","@value":"10.47416/apjod.20-0273_references_DOI_W9w91X2lurMtHnpPRY6f9y1qmsU"},{"@type":"CROSSREF","@value":"10.4012/dmj.2022-127_references_DOI_W9w91X2lurMtHnpPRY6f9y1qmsU"},{"@type":"CROSSREF","@value":"10.2209/tdcpublication.2020-0017_references_DOI_W9w91X2lurMtHnpPRY6f9y1qmsU"},{"@type":"CROSSREF","@value":"10.2186/jpr.jpr_d_24_00304_references_DOI_W9w91X2lurMtHnpPRY6f9y1qmsU"}]}