- 【Updated on May 12, 2025】 Integration of CiNii Dissertations and CiNii Books into CiNii Research
- Trial version of CiNii Research Automatic Translation feature is available on CiNii Labs
- Suspension and deletion of data provided by Nikkei BP
- Regarding the recording of “Research Data” and “Evidence Data”
Mechanomyogram and Electromyogram Responses of Upper Limb During Sustained Isometric Fatigue with Varying Shoulder and Elbow Postures.
-
- Mamaghani Nasser Koleini
- Ergonomics Section, Graduate School of Science and Technology, Chiba University
-
- Shimomura Yoshihiro
- Ergonomics Section, Department of Design and Architecture, Faculty of Engineering, Chiba University
-
- Iwanaga Koichi
- Ergonomics Section, Graduate School of Science and Technology, Chiba University
-
- Katsuura Tetsuo
- Ergonomics Section, Department of Design and Architecture, Faculty of Engineering, Chiba University
Search this article
Description
To investigate the behavior of mechanomyogram (MMG) and electromyogram (EMG) signals in the time and frequency domains during sustained isometric contraction, MMG and surface EMG were obtained simultaneously from four muscles: upper trapezius (TP), anterior deltoid (DL), biceps brachii (BB), and brachioradialis (BR) of 10 healthy male subjects. Experimental conditions consisted of 27 combinations of 9 postures [3 shoulder angles (SA): 0°, 30°, 60° and 3 elbow angles (EA): 120°, 90°, 60°] and 3 contraction levels: 20%, 40%, and 60% of maximum voluntary contraction (MVC). Subjective evaluations of fatigue were also assessed using the Borg scale at intervals of 60, 30, and 10 sec at 20%, 40%, and 60% MVC tests, respectively. The mean power frequency (MPF) and root mean square (RMS) of both signals were calculated. The current study found clear and significant relationships among physiological and psychological parameters on the one hand and SA and EA on the other. EA's effect on MVC was found to be significant. SA had a highly significant effect on both endurance time and Borg scale. In all experimental conditions, significant correlations were found between the changes in MPF and RMS of EMG in BB with SA and EA (or muscle length). In all four muscles, MMG frequency content was two or three times lower than EMG frequency content. During sustained isometric contraction, the EMG signal showed the well-known shift to lower frequencies (a continuous decrease from onset to completion of the contraction). In contrast, the MMG spectra did not show any shift, although its form changed (generally remaining about constant). Throughout the contraction, increased RMS of EMG was found for all tests, whereas in the MMG signal, a significant progressive increase in RMS was observed only at 20% MVC in all four muscles. This supports the hypothesis that the RMS amplitude of the MMG signal produced during contraction is highly correlated with force production. Possible explanations for this behavioral difference between the MMG and EMG signals are discussed. <br>
Journal
-
- Journal of PHYSIOLOGICAL ANTHROPOLOGY and Applied Human Science
-
Journal of PHYSIOLOGICAL ANTHROPOLOGY and Applied Human Science 21 (1), 29-43, 2002
Japan Society of Physiological Anthropology
- Tweet
Details 詳細情報について
-
- CRID
- 1390282679763463296
-
- NII Article ID
- 110002528539
-
- NII Book ID
- AA11462444
-
- COI
- 1:STN:280:DC%2BD383gs1SqsA%3D%3D
-
- ISSN
- 13475355
- 13453475
- https://id.crossref.org/issn/13413473
-
- PubMed
- 11938607
-
- Text Lang
- en
-
- Article Type
- journal article
-
- Data Source
-
- JaLC
- Crossref
- PubMed
- NDL Digital Collections (NII-ELS)
- CiNii Articles
- OpenAIRE
-
- Abstract License Flag
- Disallowed