{"@context":{"@vocab":"https://cir.nii.ac.jp/schema/1.0/","rdfs":"http://www.w3.org/2000/01/rdf-schema#","dc":"http://purl.org/dc/elements/1.1/","dcterms":"http://purl.org/dc/terms/","foaf":"http://xmlns.com/foaf/0.1/","prism":"http://prismstandard.org/namespaces/basic/2.0/","cinii":"http://ci.nii.ac.jp/ns/1.0/","datacite":"https://schema.datacite.org/meta/kernel-4/","ndl":"http://ndl.go.jp/dcndl/terms/","jpcoar":"https://github.com/JPCOAR/schema/blob/master/2.0/"},"@id":"https://cir.nii.ac.jp/crid/1390282680080225152.json","@type":"Article","productIdentifier":[{"identifier":{"@type":"DOI","@value":"10.1253/circj.cj-09-0221"}},{"identifier":{"@type":"URI","@value":"http://www.jstage.jst.go.jp/article/circj/73/SupplementA/73_CJ-09-0221/_pdf"}},{"identifier":{"@type":"NAID","@value":"10025939151"}},{"identifier":{"@type":"URI","@value":"https://search.jamas.or.jp/link/ui/2009311180"}}],"dc:title":[{"@language":"en","@value":"Implantable Left Ventricular Assist System"}],"dc:language":"en","description":[{"type":"abstract","notation":[{"@language":"en","@value":"The first clinical application of the first-generation pulsatile implantable left ventricular assist system (LVAS) was in the mid 1980 s as a bridge to transplantation and contributed to an advancement of this field from a clinical experiment to an established therapeutic option for treating advanced heart failure patients. However, there have been technological limitations that have surfaced as longer-term experience has been gained. These include a high incidence of thromboembolic complications, infection, mechanical failures associated with moving parts, and the large size of both implantable pump and percutaneous cable. In order to overcome the limitations of the first-generation pulsatile LVAS, a smaller rotary blood pump LVAS emerged as a possible alternative in the 1990 s and these new generation LVAS are in various stages of development and clinical application. This article reviews the history and current status of the implantable LVAS. (<i>Circ J</i> 2009; <b>Suppl A:</b> A-48-A-54)<br>"}],"abstractLicenseFlag":"disallow"}],"creator":[{"@id":"https://cir.nii.ac.jp/crid/1410282680080225152","@type":"Researcher","personIdentifier":[{"@type":"NRID","@value":"9000017041818"}],"foaf:name":[{"@language":"en","@value":"Nojiri Chisato"}],"jpcoar:affiliationName":[{"@language":"en","@value":"Terumo Heart, Inc, Ann Arbor"}]}],"publication":{"publicationIdentifier":[{"@type":"PISSN","@value":"13469843"},{"@type":"LISSN","@value":"13469843"},{"@type":"EISSN","@value":"13474820"},{"@type":"NCID","@value":"AA11591968"}],"prism:publicationName":[{"@language":"en","@value":"Circulation Journal"},{"@language":"en","@value":"Circ J"}],"dc:publisher":[{"@language":"en","@value":"The Japanese Circulation Society"},{"@language":"ja","@value":"一般社団法人 日本循環器学会"}],"prism:publicationDate":"2009","prism:volume":"73","prism:number":"SupplementA","prism:startingPage":"A48","prism:endingPage":"A54"},"reviewed":"false","url":[{"@id":"http://www.jstage.jst.go.jp/article/circj/73/SupplementA/73_CJ-09-0221/_pdf"},{"@id":"https://search.jamas.or.jp/link/ui/2009311180"}],"availableAt":"2009","foaf:topic":[{"@id":"https://cir.nii.ac.jp/all?q=Chronic%20heart%20failure","dc:title":"Chronic heart failure"},{"@id":"https://cir.nii.ac.jp/all?q=Congestive%20heart%20failure","dc:title":"Congestive heart failure"},{"@id":"https://cir.nii.ac.jp/all?q=Dilated%20cardiomyopathy","dc:title":"Dilated cardiomyopathy"},{"@id":"https://cir.nii.ac.jp/all?q=Heart-assist%20device","dc:title":"Heart-assist device"}],"relatedProduct":[{"@id":"https://cir.nii.ac.jp/crid/1360574095470918400","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Use of a Continuous-Flow Device in Patients Awaiting Heart Transplantation"}]},{"@id":"https://cir.nii.ac.jp/crid/1360855570225810560","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"A Prospective, Multicenter Trial of the VentrAssist Left Ventricular Assist Device for Bridge to Transplant: Safety and Efficacy"}]},{"@id":"https://cir.nii.ac.jp/crid/1360855570578277248","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Multicenter clinical evaluation of the HeartMate 1000 IP left ventricular assist device"}]},{"@id":"https://cir.nii.ac.jp/crid/1361137046462340096","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Worldwide Experience With the TCI HeartMate® System: Issues and Future Perspective"}]},{"@id":"https://cir.nii.ac.jp/crid/1361418518431836928","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"EPIDEMIOLOGY OF HEARY FAILURE"}]},{"@id":"https://cir.nii.ac.jp/crid/1361418520252713344","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Current Trends in Heart Transplantation"}]},{"@id":"https://cir.nii.ac.jp/crid/1361418520253318656","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"First experiences with a novel magnetically suspended axial flow left ventricular assist device"}]},{"@id":"https://cir.nii.ac.jp/crid/1361699994130791680","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Heart Disease and Stroke Statistics—2009 Update"}]},{"@id":"https://cir.nii.ac.jp/crid/1361699994570550272","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Long-Term Use of a Left Ventricular Assist Device for End-Stage Heart Failure"}]},{"@id":"https://cir.nii.ac.jp/crid/1362544418329697536","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Worldwide Experience With the MicroMed DeBakey Ventricular Assist Device® as a Bridge to Transplantation"}]},{"@id":"https://cir.nii.ac.jp/crid/1362544419989738112","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"ACC/AHA 2005 Guideline Update for the Diagnosis and Management of Chronic Heart Failure in the Adult—Summary Article"}]},{"@id":"https://cir.nii.ac.jp/crid/1362544420218602624","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Multicenter clinical evaluation of the HeartMate vented electric left ventricular assist system in patients awaiting heart transplantation"}]},{"@id":"https://cir.nii.ac.jp/crid/1363107370000168064","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Mechanical Circulatory Support With the Novacor LVAS: World-Wide Clinical Results"}]},{"@id":"https://cir.nii.ac.jp/crid/1363388843956062720","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Outcomes of Left Ventricular Assist Device Implantation as Destination Therapy in the Post-REMATCH Era"}]},{"@id":"https://cir.nii.ac.jp/crid/1363951794959806848","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Cardiac Replacement with a Total Artificial Heart as a Bridge to Transplantation"}]},{"@id":"https://cir.nii.ac.jp/crid/1364233268436750208","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Use of the Flowmaker (Jarvik 2000) Left Ventricular Assist Device for Destination Therapy and Bridging to Transplantation"}]},{"@id":"https://cir.nii.ac.jp/crid/1364233271154841856","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Registry of the International Society for Heart and Lung Transplantation: Twenty-fifth Official Adult Heart Transplant Report—2008"}]},{"@id":"https://cir.nii.ac.jp/crid/1390001205103677696","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy","isCitedBy"],"jpcoar:relatedTitle":[{"@language":"en","@value":"How to Treat Stage D Heart Failure?  - When to Implant Left Ventricular Assist Devices in the Era of Continuous Flow Pumps? -"}]},{"@id":"https://cir.nii.ac.jp/crid/1390001205104524672","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["references","cites"],"jpcoar:relatedTitle":[{"@language":"en","@value":"The DuraHeart VAD, a Magnetically Levitated Centrifugal Pump  The University of Vienna Bridge-to-Transplant Experience"}]},{"@id":"https://cir.nii.ac.jp/crid/1390001205510798336","@type":"Article","relationType":["isReferencedBy","isCitedBy"],"jpcoar:relatedTitle":[{"@language":"ja","@value":"DuraHeart<sup>TM</sup>左心補助人工心臓のグローバル開発"},{"@language":"en","@value":"Global Development of the DuraHeart<sup>TM</sup> Left Ventricular Assist System"},{"@value":"DuraHeart左心補助人工心臓のグローバル開発"},{"@language":"ja-Kana","@value":"DuraHeart サシン ホジョ ジンコウ シンゾウ ノ グローバル カイハツ"}]},{"@id":"https://cir.nii.ac.jp/crid/1390001206430981888","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["references"],"jpcoar:relatedTitle":[{"@language":"en","@value":"Treatment of Endstage Heart Disease With Mechanical Circulatory Assistance"}]},{"@id":"https://cir.nii.ac.jp/crid/1390848250108916736","@type":"Article","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@language":"en","@value":"Current status and future of development of ventricular assist devices in Japan"},{"@language":"ja","@value":"補助人工心臓の現状と今後の展開"}]},{"@id":"https://cir.nii.ac.jp/crid/1570291225967961856","@type":"Article","relationType":["cites"],"jpcoar:relatedTitle":[{"@language":"en","@value":"Current trends in heart transplantation"}]},{"@id":"https://cir.nii.ac.jp/crid/1570291225967963136","@type":"Article","relationType":["cites"],"jpcoar:relatedTitle":[{"@language":"en","@value":"Outcomes of left ventricular assist device implantation as destination therapy in the post-REMATH era : Implications for patient selection"}]},{"@id":"https://cir.nii.ac.jp/crid/1570572700944669440","@type":"Article","relationType":["cites"],"jpcoar:relatedTitle":[{"@language":"en","@value":"Worldwide experience with the TCI HeartMate system : Issues and future perspective"}]},{"@id":"https://cir.nii.ac.jp/crid/1570572700944671872","@type":"Article","relationType":["cites"],"jpcoar:relatedTitle":[{"@language":"en","@value":"Registry of the International Society for Heart and Lung Transplantation : Twenty-fifth official adult heart transplant report-2008"}]},{"@id":"https://cir.nii.ac.jp/crid/1570572700944674176","@type":"Article","relationType":["cites"],"jpcoar:relatedTitle":[{"@language":"en","@value":"Cardiac replacement with a total artificial heart as a bridge to transplantation"}]},{"@id":"https://cir.nii.ac.jp/crid/1571417125874801920","@type":"Article","relationType":["cites"],"jpcoar:relatedTitle":[{"@language":"en","@value":"Mechanical circulatory support with the Novacor LVAS : World wide clinical results"}]},{"@id":"https://cir.nii.ac.jp/crid/1571417125874806784","@type":"Article","relationType":["cites"],"jpcoar:relatedTitle":[{"@language":"en","@value":"ACC/AHA 2005 Guideline update for the diagnosis and management of chronic heart failure in adult-summary article : A report of the American College of Cardiology/American Heart Association Task Force on practical guidelines"}]},{"@id":"https://cir.nii.ac.jp/crid/1571698600851515776","@type":"Article","relationType":["cites"],"jpcoar:relatedTitle":[{"@language":"en","@value":"Clinical effectiveness and need for long-term circulatory support"}]},{"@id":"https://cir.nii.ac.jp/crid/1571698602149722880","@type":"Article","relationType":["cites"],"jpcoar:relatedTitle":[{"@language":"en","@value":"Teratment of Endstage Heart Disease With Mechanical Circulatory Assistance"}]},{"@id":"https://cir.nii.ac.jp/crid/1571980075828221568","@type":"Article","relationType":["cites"],"jpcoar:relatedTitle":[{"@language":"en","@value":"HeartMate LVAS Investigators. Left Ventricular Assist System. Multicenter clinical evaluation of the HeartMate vented electric left ventricular assist system in patients awaiting heart transplantation"}]},{"@id":"https://cir.nii.ac.jp/crid/1571980075828222720","@type":"Article","relationType":["cites"],"jpcoar:relatedTitle":[{"@language":"en","@value":"Long-term use of a left ventricular assist device for end-stage heart failure"}]},{"@id":"https://cir.nii.ac.jp/crid/1572261550804934016","@type":"Article","relationType":["cites"],"jpcoar:relatedTitle":[{"@language":"en","@value":"First experiences with a novel magnetically suspended axial flow left ventricular assist device"}]},{"@id":"https://cir.nii.ac.jp/crid/1572824500758357120","@type":"Article","relationType":["cites"],"jpcoar:relatedTitle":[{"@language":"en","@value":"Worldwide experience with the MicroMed DeBakey ventricular assist device as a bridge to transplantation"}]},{"@id":"https://cir.nii.ac.jp/crid/1573105975735066368","@type":"Article","relationType":["cites"],"jpcoar:relatedTitle":[{"@language":"en","@value":"A prospective, multicenter trial of the VentrAssist left ventricular assist device for bridge to transplant : Safety and efficacy"}]},{"@id":"https://cir.nii.ac.jp/crid/1573668925688486912","@type":"Article","relationType":["cites"],"jpcoar:relatedTitle":[{"@language":"en","@value":"Epidemiology of heart failure"}]},{"@id":"https://cir.nii.ac.jp/crid/1573668925688491008","@type":"Article","relationType":["cites"],"jpcoar:relatedTitle":[{"@language":"en","@value":"Multicenter clinical evaluation of the HeartMate 1000 IP left ventricular assist device"}]},{"@id":"https://cir.nii.ac.jp/crid/1573668925688492288","@type":"Article","relationType":["cites"],"jpcoar:relatedTitle":[{"@language":"en","@value":"Use of Flowmaker (Jarvik 2000) left ventricular assist device for destination therapy and bridging to transplantation"}]},{"@id":"https://cir.nii.ac.jp/crid/1573668925688493568","@type":"Article","relationType":["cites"],"jpcoar:relatedTitle":[{"@language":"en","@value":"Use of a continuous-flow device in patients awaiting heart transplantation"}]},{"@id":"https://cir.nii.ac.jp/crid/1573950400665199872","@type":"Article","relationType":["cites"],"jpcoar:relatedTitle":[{"@language":"en","@value":"Heart disease and stroke statistics : 2009 update"}]}],"dataSourceIdentifier":[{"@type":"JALC","@value":"oai:japanlinkcenter.org:0033309624"},{"@type":"CROSSREF","@value":"10.1253/circj.cj-09-0221"},{"@type":"CIA","@value":"10025939151"},{"@type":"CROSSREF","@value":"10.1253/circj.cj-11-0621_references_DOI_NYGSGasVUVSUDpHq6bRaJL9qRka"},{"@type":"CROSSREF","@value":"10.3918/jsicm.27_177_references_DOI_NYGSGasVUVSUDpHq6bRaJL9qRka"},{"@type":"CROSSREF","@value":"10.5759/jscas.13.7_references_DOI_NYGSGasVUVSUDpHq6bRaJL9qRka"}]}