Comparison of Chronic Angioscopic Findings of Bare Metal Stents, 1st-Generation Drug-Eluting Stents and 2nd-Generation Drug-Eluting Stents – Multicenter Study of Intra-Coronary Angioscopy After Stent (MICASA) –
-
- Dai Kazuoki
- Department of Cardiology, Hiroshima City Hospital
-
- Matsuoka Hiroshi
- Department of Cardiology, Ehime Prefectural Imabari Hospital
-
- Kawakami Hideo
- Department of Cardiology, Ehime Prefectural Imabari Hospital
-
- Sato Tetsuya
- Department of Cardiology, Okayama Red Cross Hospital
-
- Watanabe Kouki
- Department of Cardiology, Saiseikai Matsuyama Hospital
-
- Nakama Yasuharu
- Department of Cardiology, Hiroshima City Hospital
-
- Ishihara Masaharu
- Division of Coronary Heart Disease, Department of Internal Medicine, Hyogo College of Medicine
Search this article
Description
<p>Background:No previous study has reported a comprehensive comparison of the chronic angioscopic findings after bare metal stent (BMS), and 1st- and 2nd-generation drug-eluting stents (DES).</p><p>Methods and Results:The Multicenter Study on Intra-Coronary Angioscopy after Stent (MICASA) is a multicenter registry of coronary angioscopy. A total of 264 stents were observed by coronary angioscopy 1 year after PCI. There were 15 BMS, 90 1st-generation DES, and 159 2nd-generation DES. Neointimal coverage (NC) of the stent was classified into 4 grades from 0 (no coverage) to 3 (complete coverage). Yellow color (YC) of plaque at the stented segment was graded from 0 (white) to 3 (bright yellow). Minimum (Min-) and Maximum (Max-) NC grade were significantly lower with 1st- and 2nd-generation DES than with BMS. Although the Max-NC grade was similar, the Min-NC grade was significantly higher for 2nd-generation DES than for 1st-generation DES. Both the YC grade and the incidence of thrombus with 2nd-generation DES were lower than with the 1st-generation DES and were comparable to BMS. Multivariate analysis showed that low-density lipoprotein, 1st-generation DES, and acute coronary syndrome were independent factors for yellow plaque (YG2 or 3), and that hypertension and 1st-generation DES were independent factors for the incidence of thrombus.</p><p>Conclusions:Coronary angioscopy revealed more homogeneous coverage with white neointima and less thrombus after 2nd-generation DES as compared with 1st-generation DES. These findings may explain the favorable clinical outcomes observed for patients treated with 2nd-generation DES. (Circ J 2016; 80: 1916–1921)</p>
Journal
-
- Circulation Journal
-
Circulation Journal 80 (9), 1916-1921, 2016
The Japanese Circulation Society
- Tweet
Details 詳細情報について
-
- CRID
- 1390282680085524224
-
- NII Article ID
- 130005406846
-
- NII Book ID
- AA11591968
-
- ISSN
- 13474820
- 13469843
-
- NDL BIB ID
- 027558279
-
- PubMed
- 27357218
-
- Text Lang
- en
-
- Article Type
- journal article
-
- Data Source
-
- JaLC
- NDL Search
- Crossref
- PubMed
- CiNii Articles
- KAKEN
- OpenAIRE
-
- Abstract License Flag
- Disallowed