{"@context":{"@vocab":"https://cir.nii.ac.jp/schema/1.0/","rdfs":"http://www.w3.org/2000/01/rdf-schema#","dc":"http://purl.org/dc/elements/1.1/","dcterms":"http://purl.org/dc/terms/","foaf":"http://xmlns.com/foaf/0.1/","prism":"http://prismstandard.org/namespaces/basic/2.0/","cinii":"http://ci.nii.ac.jp/ns/1.0/","datacite":"https://schema.datacite.org/meta/kernel-4/","ndl":"http://ndl.go.jp/dcndl/terms/","jpcoar":"https://github.com/JPCOAR/schema/blob/master/2.0/"},"@id":"https://cir.nii.ac.jp/crid/1390282680221439616.json","@type":"Article","productIdentifier":[{"identifier":{"@type":"DOI","@value":"10.18948/shasetaikai.2013.1.0_69"}},{"identifier":{"@type":"NAID","@value":"130006896949"}}],"dc:title":[{"@language":"ja","@value":"水熱源ヒートポンプによる省エネルギー給湯の可能性"},{"@language":"en","@value":"Energy Conservation Possibilities of Domestic Hot Water Supply by Water-Source Heat Pumps"}],"dc:language":"ja","description":[{"type":"abstract","notation":[{"@language":"ja","@value":"<p>省エネルギーと利便性を目指した新しい給湯システムを提示する。このシステムは水ループとこれに接続する分散型水熱源ヒートポンプで局所式給湯し,水ループの循環水温度は未利用熱等で20℃程度に保たれる。瞬間式の水熱源給湯ヒートポンプを試作実験した結果,給湯温度が40℃のとき,COPは約8が得られた。冷媒にCO2を用いてローレンツサイクルにすれば,さらに高いCOPが得られることを予測した。</p>"}],"abstractLicenseFlag":"disallow"}],"creator":[{"@id":"https://cir.nii.ac.jp/crid/1410282680221439618","@type":"Researcher","personIdentifier":[{"@type":"NRID","@value":"9000391680371"}],"foaf:name":[{"@language":"ja","@value":"日野 俊之"}],"jpcoar:affiliationName":[{"@language":"ja","@value":"東京大学"}]},{"@id":"https://cir.nii.ac.jp/crid/1410282680221439616","@type":"Researcher","personIdentifier":[{"@type":"NRID","@value":"9000391680372"}],"foaf:name":[{"@language":"ja","@value":"大岡 龍三"}],"jpcoar:affiliationName":[{"@language":"ja","@value":"東京大学"}]},{"@id":"https://cir.nii.ac.jp/crid/1410282680221439620","@type":"Researcher","personIdentifier":[{"@type":"NRID","@value":"9000391680373"}],"foaf:name":[{"@language":"ja","@value":"小野 勝男"}],"jpcoar:affiliationName":[{"@language":"ja","@value":"LIXIL"}]},{"@id":"https://cir.nii.ac.jp/crid/1410282680221439619","@type":"Researcher","personIdentifier":[{"@type":"NRID","@value":"9000391680374"}],"foaf:name":[{"@language":"ja","@value":"吉田 吏志"}],"jpcoar:affiliationName":[{"@language":"ja","@value":"LIXIL"}]},{"@id":"https://cir.nii.ac.jp/crid/1410282680221439617","@type":"Researcher","personIdentifier":[{"@type":"NRID","@value":"9000391680375"}],"foaf:name":[{"@language":"ja","@value":"兒玉 和生"}],"jpcoar:affiliationName":[{"@language":"ja","@value":"東京大学"}]}],"publication":{"publicationIdentifier":[{"@type":"PISSN","@value":"18803806"},{"@type":"EISSN","@value":"24242179"}],"prism:publicationName":[{"@language":"ja","@value":"空気調和・衛生工学会大会　学術講演論文集"},{"@language":"en","@value":"Techinical Papers of Annual Meeting the Society of Heating,Air-conditioning and Sanitary Engineers of Japan"}],"dc:publisher":[{"@language":"en","@value":"The Society of Heating,Air-Conditioning&Sanitary Engineers of Japan"},{"@language":"ja","@value":"公益社団法人 空気調和・衛生工学会"}],"prism:publicationDate":"2013","prism:volume":"2013.1","prism:number":"0","prism:startingPage":"69","prism:endingPage":"72"},"jpcoar:conferenceName":"平成25年度空気調和・衛生工学会大会（長野）","availableAt":"2013","foaf:topic":[{"@id":"https://cir.nii.ac.jp/all?q=%E7%B5%A6%E6%B9%AF","dc:title":"給湯"},{"@id":"https://cir.nii.ac.jp/all?q=%E3%83%92%E3%83%BC%E3%83%88%E3%83%9D%E3%83%B3%E3%83%97","dc:title":"ヒートポンプ"},{"@id":"https://cir.nii.ac.jp/all?q=%E6%9C%AA%E5%88%A9%E7%94%A8%E7%86%B1","dc:title":"未利用熱"},{"@id":"https://cir.nii.ac.jp/all?q=%E6%B0%B4%E3%83%AB%E3%83%BC%E3%83%97","dc:title":"水ループ"},{"@id":"https://cir.nii.ac.jp/all?q=%E3%83%AD%E3%83%BC%E3%83%AC%E3%83%B3%E3%83%84%E3%82%B5%E3%82%A4%E3%82%AF%E3%83%AB","dc:title":"ローレンツサイクル"},{"@id":"https://cir.nii.ac.jp/all?q=%E9%80%86%E3%82%AB%E3%83%AB%E3%83%8E%E3%83%BC%E3%82%B5%E3%82%A4%E3%82%AF%E3%83%AB","dc:title":"逆カルノーサイクル"}],"dataSourceIdentifier":[{"@type":"JALC","@value":"oai:japanlinkcenter.org:2003442497"},{"@type":"CIA","@value":"130006896949"}]}