{"@context":{"@vocab":"https://cir.nii.ac.jp/schema/1.0/","rdfs":"http://www.w3.org/2000/01/rdf-schema#","dc":"http://purl.org/dc/elements/1.1/","dcterms":"http://purl.org/dc/terms/","foaf":"http://xmlns.com/foaf/0.1/","prism":"http://prismstandard.org/namespaces/basic/2.0/","cinii":"http://ci.nii.ac.jp/ns/1.0/","datacite":"https://schema.datacite.org/meta/kernel-4/","ndl":"http://ndl.go.jp/dcndl/terms/","jpcoar":"https://github.com/JPCOAR/schema/blob/master/2.0/"},"@id":"https://cir.nii.ac.jp/crid/1390282681366513792.json","@type":"Article","productIdentifier":[{"identifier":{"@type":"DOI","@value":"10.6009/jjrt.kj00000921538"}},{"identifier":{"@type":"URI","@value":"https://www.jstage.jst.go.jp/article/jjrt/58/12/58_KJ00000921538/_pdf"}},{"identifier":{"@type":"NAID","@value":"110003434028"}},{"identifier":{"@type":"URI","@value":"https://search.jamas.or.jp/link/ui/2003196503"}}],"dc:title":[{"@language":"ja","@value":"造影3DMRAにおける血管径と撮像タイミングについて : 拍動流によるシミュレーション"},{"@language":"en","@value":"A Study of the Influence Scan Timing and Depiction of Blood Vessel Diameter in CE-3DMRA : Simulation by Pulsatile Flow"},{"@value":"A study of the influence scan timing and depiction of blood vessel diameter in CE‐3DMRA: simulation by pulsitile flow"}],"dc:language":"ja","description":[{"type":"abstract","notation":[{"@language":"en","@value":"In imaging using contrast-enhanced three-dimensional magnetic resonance angiography (CE-3DMRA), optimizing the delay time from the start of intravenous injection of contrast medium to the start of scanning has generally been an important concern when obtaining blood vessel images of good contrast. Recent methods of mechanically assessing the attainment of contrast medium injection include Smart-Prep and others. Another method is the Test Bolus, in which a small amount of contrast medium determines the timing of scan start, in quest of the time intensity curve. Because these methods are not necessarily satisfactory, the corrected method is used in clinical cases. In terms of how scan timing affects blood vessel depiction, no study has examined pulsatile flow, which is carried out by simulation. On the other hand, there are reports on data filling of k-space using imitation blood vessels on a computer and simple experimental equipment. This research examined experimentally blood vessel depiction according to scan timing and the diameter of blood vessels by using a systemic circulation simulator that incorporated hemodynamic circulation in which pulsatile flow is the same as that of a human body, using an artificial heart developed especially for MRI. It is thought that scan timing in CE-3DMRA affects the depiction of blood vessels for which the diameter of the blood vessel differs from the experimental result. Phase-encoding k-space data filling is the contrast-to-noise ratio (CNR) of each blood vessel irrespective of sequential and centric k-space ordering. The timing shift phenomenon, in which a blood vessel is so thin that the scan timing is overdue and shows a relatively high value, can occur. Moreover, that scan timing affects not only the diameter of a blood vessel but also depiction of the narrowing of a stenotic blood vessel or a branch blood vessel was demonstrated clinically and experimentally. Therefore, blood vessel depiction changes with scan timing, and it is clinically important to determine the time of arrival of contrast medium and the duration of the enhancement effect in quest of the time intensity curve by test bolus when clearly describing the target blood vessel."}],"abstractLicenseFlag":"disallow"}],"creator":[{"@id":"https://cir.nii.ac.jp/crid/1410001206368100994","@type":"Researcher","personIdentifier":[{"@type":"NRID","@value":"9000005054531"}],"foaf:name":[{"@language":"ja","@value":"矢部 仁"},{"@language":"en","@value":"YABE HITOSHI"}],"jpcoar:affiliationName":[{"@language":"en","@value":"Department of Technological Radiology, Saitama Cardiovascular and Respiratory Center"},{"@language":"ja","@value":"埼玉県立循環器・呼吸器病センター放射線技術部"}]},{"@id":"https://cir.nii.ac.jp/crid/1410282681362213638","@type":"Researcher","personIdentifier":[{"@type":"NRID","@value":"9000005054532"}],"foaf:name":[{"@language":"ja","@value":"村田 孝弘"},{"@language":"en","@value":"MURATA TAKAHIRO"}],"jpcoar:affiliationName":[{"@language":"en","@value":"Department of Technological Radiology, Saitama Cardiovascular and Respiratory Center"},{"@language":"ja","@value":"埼玉県立循環器・呼吸器病センター放射線技術部"}]},{"@id":"https://cir.nii.ac.jp/crid/1410282681366513793","@type":"Researcher","foaf:name":[{"@language":"ja","@value":"久保田 正男"},{"@language":"en","@value":"KUBOTA MASAO"}],"jpcoar:affiliationName":[{"@language":"en","@value":"Department of Technological Radiology, Saitama Cardiovascular and Respiratory Center"},{"@language":"ja","@value":"埼玉県立循環器・呼吸器病センター放射線技術部"}]}],"publication":{"publicationIdentifier":[{"@type":"PISSN","@value":"03694305"},{"@type":"EISSN","@value":"18814883"},{"@type":"CODEN","@value":"NIPHAP"},{"@type":"PISSN","@value":"http://id.crossref.org/issn/03694305"},{"@type":"NCID","@value":"AN00197784"}],"prism:publicationName":[{"@language":"en","@value":"Japanese Journal of Radiological Technology"},{"@language":"ja","@value":"日本放射線技術学会雑誌"},{"@language":"en","@value":"Nippon Hoshasen Gijutsu Gakkai Zasshi"},{"@language":"en","@value":"Jpn. J. Radiol. Technol."},{"@language":"ja","@value":"日放技学誌"}],"dc:publisher":[{"@language":"en","@value":"Japanese Society of Radiological Technology"},{"@language":"ja","@value":"公益社団法人 日本放射線技術学会"}],"prism:publicationDate":"2002","prism:volume":"58","prism:number":"12","prism:startingPage":"1599","prism:endingPage":"1608"},"reviewed":"false","url":[{"@id":"https://www.jstage.jst.go.jp/article/jjrt/58/12/58_KJ00000921538/_pdf"},{"@id":"https://search.jamas.or.jp/link/ui/2003196503"}],"availableAt":"2002","foaf:topic":[{"@id":"https://cir.nii.ac.jp/all?q=Contrast-enhanced%20magnetic%20resonance%20angiography%20(CE-3DMRA)","dc:title":"Contrast-enhanced magnetic resonance angiography (CE-3DMRA)"},{"@id":"https://cir.nii.ac.jp/all?q=Blood%20vessel%20depiction","dc:title":"Blood vessel depiction"},{"@id":"https://cir.nii.ac.jp/all?q=k-space%20profile%20ordering","dc:title":"k-space profile ordering"},{"@id":"https://cir.nii.ac.jp/all?q=Scan%20timing","dc:title":"Scan timing"},{"@id":"https://cir.nii.ac.jp/all?q=Systemic%20circulation%20simulator","dc:title":"Systemic circulation simulator"}],"relatedProduct":[{"@id":"https://cir.nii.ac.jp/crid/1360285705162030592","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@value":"Noninvasive visualization of endoleaks after endovascular aortic aneurysm repair through unenhanced MRI with motion‐sensitized driven equilibrium preparation: Phantom experiments"}]},{"@id":"https://cir.nii.ac.jp/crid/1390001206361896576","@type":"Article","relationType":["isReferencedBy","isCitedBy"],"jpcoar:relatedTitle":[{"@language":"en","@value":"Applicability of PROSET-MRA for Evaluating Pediatric Moyamoya Disease"},{"@language":"ja","@value":"小児もやもや病における水選択的励起法付加ＭＲＡの有用性について"},{"@language":"ja-Kana","@value":"ショウニ モ ヤ モ ヤ ビョウ ニ オケル ミズ センタクテキレイキホウ フカ MRA ノ ユウヨウセイ ニ ツイテ"}]},{"@id":"https://cir.nii.ac.jp/crid/1390001206362061952","@type":"Article","relationType":["isCitedBy"],"jpcoar:relatedTitle":[{"@language":"en","@value":"Trial for Power Spectrum Analysis in Various Injection Timing for Contrast Medium"},{"@language":"ja","@value":"造影タイミングの変化におけるパワースペクトル解析の試み"},{"@language":"ja-Kana","@value":"ゾウエイ タイミング ノ ヘンカ ニ オケル パワースペクトル カイセキ ノ ココロミ"}]},{"@id":"https://cir.nii.ac.jp/crid/1390001206385531648","@type":"Article","relationType":["cites"],"jpcoar:relatedTitle":[{"@language":"ja","@value":"造影MR angiographyのシミュレーションによる検討 : 造影タイミングとk空間走査が血管像に及ぼす影響"},{"@language":"en","@value":"Study of Enhanced MR Angiography by Simulation Method"},{"@value":"152 造影MR angiographyのシミュレーションによる検討 : 造影タイミングとk空間走査が血管像に及ぼす影響"}]},{"@id":"https://cir.nii.ac.jp/crid/1390001206389037440","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isCitedBy"],"jpcoar:relatedTitle":[{"@language":"ja","@value":"Elliptical Centric法を用いた造影三次元MR Angiographyにおける造影効果持続時間および撮像タイミングに関する検討"},{"@language":"en","@value":"Duration of Enhancement and Scan Timing in Three-dimensional Contrast-enhanced MR Angiography Using the Elliptical Centric Phase-encoding Technique"}]},{"@id":"https://cir.nii.ac.jp/crid/1390282681362107264","@type":"Article","relationType":["cites"],"jpcoar:relatedTitle":[{"@language":"ja","@value":"造影剤タイミングモニタリング機能(Smart Prep<sup>®</sup>法)を使用した造影三次元MR angiographyの有用性"},{"@language":"en","@value":"Evaluation of Three-dimensional Gadolinium-enhanced MR Angiography Using the Timing Monitoring Function of Contrast Material(Smart Prep^【○!R】 Technique)"}]},{"@id":"https://cir.nii.ac.jp/crid/1390282681367163520","@type":"Article","relationType":["cites"],"jpcoar:relatedTitle":[{"@language":"ja","@value":"造影三次元MR angiographyにおける撮像タイミングに関するシミュレーション"},{"@language":"en","@value":"Simulation Study of Scan Timing in Three-dimensional Contrast-enhanced MR Angiography"}]},{"@id":"https://cir.nii.ac.jp/crid/1570854174821655168","@type":"Article","relationType":["cites"],"jpcoar:relatedTitle":[{"@value":"高速撮像の臨床-心臓大血管-"}]},{"@id":"https://cir.nii.ac.jp/crid/1571417124775079040","@type":"Article","relationType":["cites"],"jpcoar:relatedTitle":[{"@value":"造影三次元MR angiographyにおける造影持続時間に関するシミュレーション"}]},{"@id":"https://cir.nii.ac.jp/crid/1571417125791696384","@type":"Article","relationType":["isCitedBy"],"jpcoar:relatedTitle":[{"@language":"ja","@value":"3D-T1TFEにおける造影タイミングとk空間充填配列の違いによるアーチファクトについての検証"},{"@language":"en","@value":"Verifying MR Imaging Artifact by Changing the Timing of Contrast Enhancement and k-space Ordering Scheme in 3D T1TFE"}]},{"@id":"https://cir.nii.ac.jp/crid/1571698599702042624","@type":"Article","relationType":["cites"],"jpcoar:relatedTitle":[{"@language":"ja","@value":"脂肪抑制法を用いた骨盤部高速3次元造影MRAの有用性"},{"@language":"en","@value":"Fast Three-dimensional Contrast-enhanced MR Angiography of the Pelvis Using Fat Suppression Method"}]},{"@id":"https://cir.nii.ac.jp/crid/1572261549640263168","@type":"Article","relationType":["cites"],"jpcoar:relatedTitle":[{"@language":"ja","@value":"骨盤部の高速脂肪抑制付加3D造影ダイナミックMRIを用いた選択的動脈,静脈撮像"},{"@language":"en","@value":"Selective Delineation of Pelvic Arteries and Veins Using Three-dimensional Gadolinium-enhanced Dynamic MR Angiography with Fat-suppression"}]},{"@id":"https://cir.nii.ac.jp/crid/1572824499608768000","@type":"Article","relationType":["cites"],"jpcoar:relatedTitle":[{"@language":"ja","@value":"三次元造影MRAをいかに用いるか"},{"@language":"en","@value":"How Should We Use Contrast-enhanced 3D MR Angiography?"}]},{"@id":"https://cir.nii.ac.jp/crid/1573105974534901376","@type":"Article","relationType":["cites"],"jpcoar:relatedTitle":[{"@value":"ガドリニウム造影三次元MR angiography"}]},{"@id":"https://cir.nii.ac.jp/crid/1573105974635341056","@type":"Article","relationType":["cites"],"jpcoar:relatedTitle":[{"@value":"高速撮像法の基礎"}]},{"@id":"https://cir.nii.ac.jp/crid/1573105974635342080","@type":"Article","relationType":["cites"],"jpcoar:relatedTitle":[{"@language":"en","@value":"Gadolinium-enhanced MR aortography"}]}],"dataSourceIdentifier":[{"@type":"JALC","@value":"oai:japanlinkcenter.org:2002862272"},{"@type":"CROSSREF","@value":"10.6009/jjrt.kj00000921538"},{"@type":"CIA","@value":"110003434028"},{"@type":"CROSSREF","@value":"10.1002/jmri.23993_references_DOI_1BLKZRXuqaN2YNrwBm8ZNJLpNEI"},{"@type":"CROSSREF","@value":"10.6009/jjrt.67.346_references_DOI_1BLKZRXuqaN2YNrwBm8ZNJLpNEI"}]}