Measurement of Heat Quantity in a Small Cusp-Type Direct Energy Converter for Divertor Thermal Load Reduction

説明

<p>Divertor thermal load is one of the significant problems for a tokamak fusion device, and reduction of the thermal load is required. An application of a Cusp-Type Direct Energy Converter (CuspDEC), which is the device for D-3He fusion power generation to separate charged particles and convert their energy directly into electricity, was proposed to mitigate the heat flux of the divertor plasma. In order to install the CuspDEC in the narrow divertor region, a small-size CuspDEC simulator equipped with permanent magnets (PM-CuspDEC) was constructed to demonstrate divertor simulation experiment in GAMMA 10/PDX, and the performance of charge separation was examined. On one hand, development of measurement technology of heat quantity was also researched. A new calorimeter (CM) made for suppressing heat transmission has newly been manufactured to measure the small energy of end-loss flux in GAMMA 10/PDX experiment. The CM consists of a copper plate and thermocouples and can measure heat quantity and an inflow current simultaneously. The composed new CM is installed in the PM-CuspDEC, and its performance is investigated. A helium ion is used in the experiment of measuring heat quantity. The CM has successfully worked and measured the slight variation of the temperature.</p>

収録刊行物

  • Plasma and Fusion Research

    Plasma and Fusion Research 13 (0), 3405050-3405050, 2018-05-22

    一般社団法人 プラズマ・核融合学会

被引用文献 (1)*注記

もっと見る

参考文献 (4)*注記

もっと見る

詳細情報 詳細情報について

問題の指摘