{"@context":{"@vocab":"https://cir.nii.ac.jp/schema/1.0/","rdfs":"http://www.w3.org/2000/01/rdf-schema#","dc":"http://purl.org/dc/elements/1.1/","dcterms":"http://purl.org/dc/terms/","foaf":"http://xmlns.com/foaf/0.1/","prism":"http://prismstandard.org/namespaces/basic/2.0/","cinii":"http://ci.nii.ac.jp/ns/1.0/","datacite":"https://schema.datacite.org/meta/kernel-4/","ndl":"http://ndl.go.jp/dcndl/terms/","jpcoar":"https://github.com/JPCOAR/schema/blob/master/2.0/"},"@id":"https://cir.nii.ac.jp/crid/1390291158024687232.json","@type":"Article","productIdentifier":[{"identifier":{"@type":"DOI","@value":"10.6009/jjrt.780201"}},{"identifier":{"@type":"PMID","@value":"35185093"}},{"identifier":{"@type":"NDL_BIB_ID","@value":"032015435"}},{"identifier":{"@type":"URI","@value":"http://id.ndl.go.jp/bib/032015435"}},{"identifier":{"@type":"URI","@value":"https://ndlsearch.ndl.go.jp/books/R000000004-I032015435"}},{"identifier":{"@type":"URI","@value":"https://www.jstage.jst.go.jp/article/jjrt/78/2/78_780201/_pdf"}},{"identifier":{"@type":"NAID","@value":"130008161709"}},{"identifier":{"@type":"URI","@value":"https://search.jamas.or.jp/link/ui/2022111536"}}],"resourceType":"学術雑誌論文(journal article)","dc:title":[{"@language":"en","@value":"Development of the Radiation Protective Curtain for the Dose Reduction of Caregivers during Computed Tomography Examinations"},{"@language":"ja","@value":"CT撮影時における介助者の被ばく低減を目的とした放射線防護カーテンの開発"},{"@language":"ja-Kana","@value":"CT サツエイジ ニ オケル カイジョシャ ノ ヒバクテイゲン オ モクテキ ト シタ ホウシャセン ボウゴ カーテン ノ カイハツ"}],"dc:language":"ja","description":[{"type":"abstract","notation":[{"@language":"en","@value":"<p><i>Purpose</i>: During computed tomography (CT) examinations, it may be necessary to assist the patient to maintain an appropriate body position. However, there is little protective equipment available for caregivers who approach the gantry. This study aimed to evaluate the effectiveness of novel radiation protective curtains in reducing radiation exposure to caregivers while assisting patients, especially during CT examinations of the head. <i>Method</i>: The absorbed dose in air around the gantry during CT examinations of the head was measured using glass dosimeters. The measurement points from the center of the gantry were 40 to 120 cm in the front, 0 to 100 cm for each side in the right and left, and 60 to 180 cm from the floor. Measurements were performed at each 20-cm interval, and all points were accumulated 10 times. The absorbed dose in air in a CT room was compared with and without the protective curtains. Next, we assumed the height of the caregiver to be 170 cm, and measured the points for the crystalline lens, chest, and abdomen. Also, using the protective glasses and the protective apron, we measured the absorbed dose in air for the caregivers behind the protective curtains. <i>Result</i>: The absorbed exposure dose in air toward the crystalline lenses, chest, and abdomen was reduced more than 90% by using the protective curtains and more than 95% by using the protective apron and protective glasses in addition to them. <i>Conclusion</i>: This study showed the usefulness of protective curtains in reducing the absorbed exposure dose in air to caregivers.</p>"},{"@language":"ja","@value":"<p>【目的】CT検査において，患者の監視や体動抑制等が必要な場合，検査室内で患者介助を行う医療従事者に特化した放射線防護用具を用いた研究報告は見かけない．われわれは，特に介助機会の多い頭部CT検査時における介助者被ばくの低減を目的として，放射線防護カーテン（以下，防護カーテン）を開発し，その有用性について検討した．【方法】CT装置にてランドファントムを頭部条件で撮影し，防護カーテンの有無における介助者の水晶体，胸部，腹部を想定した位置の空気吸収線量（以下，空間線量）をガラス線量計にて測定した．【結果】防護カーテンの使用により，CT室内の広域にわたる空間線量は大きく低減した．また，水晶体，胸部，腹部の位置では約90%以上の空間線量が低減し，更に，防護カーテンに防護眼鏡および防護衣を併用することにより，約95%以上の空間線量が低減した．【結語】本研究において製作した防護カーテンの有用性が示唆された．</p>"}],"abstractLicenseFlag":"disallow"}],"creator":[{"@id":"https://cir.nii.ac.jp/crid/1410291158024687234","@type":"Researcher","personIdentifier":[{"@type":"NRID","@value":"9000415350490"}],"foaf:name":[{"@language":"en","@value":"Kato Kyoichi"},{"@language":"ja","@value":"加藤 京一"}],"jpcoar:affiliationName":[{"@language":"ja","@value":"昭和大学大学院保健医療学研究科"},{"@language":"en","@value":"Graduate School of Health Sciences, Showa University"},{"@language":"ja","@value":"学校法人昭和大学統括放射線技術部"},{"@language":"en","@value":"Department of Radiology, Showa University"}]},{"@id":"https://cir.nii.ac.jp/crid/1410291158024687236","@type":"Researcher","personIdentifier":[{"@type":"NRID","@value":"9000415350489"}],"foaf:name":[{"@language":"en","@value":"Hoshina Takumi"},{"@language":"ja","@value":"保科 匠"}],"jpcoar:affiliationName":[{"@language":"en","@value":"Hoshina Co., Ltd"},{"@language":"ja","@value":"株式会社保科製作所"}]},{"@id":"https://cir.nii.ac.jp/crid/1410291158024687235","@type":"Researcher","personIdentifier":[{"@type":"NRID","@value":"9000415350487"}],"foaf:name":[{"@language":"en","@value":"Nakashima Junya"},{"@language":"ja","@value":"中島 潤也"}],"jpcoar:affiliationName":[{"@language":"ja","@value":"昭和大学江東豊洲病院放射線技術部"},{"@language":"en","@value":"Department of Radiological Technology, Showa University Koto Toyosu Hospital"},{"@language":"ja","@value":"昭和大学大学院保健医療学研究科"},{"@language":"en","@value":"Graduate School of Health Sciences, Showa University"}]},{"@id":"https://cir.nii.ac.jp/crid/1410291158024687233","@type":"Researcher","personIdentifier":[{"@type":"NRID","@value":"9000415350488"}],"foaf:name":[{"@language":"ja","@value":"宮坂 航示"},{"@language":"en","@value":"Miyasaka Koji"}],"jpcoar:affiliationName":[{"@language":"en","@value":"Department of Radiological Technology, Showa University Fujigaoka Hospital (Current address: Yamato Municipal Hospital)"},{"@language":"ja","@value":"昭和大学藤が丘病院放射線技術部（現　大和市立病院診療放射線科）"}]},{"@id":"https://cir.nii.ac.jp/crid/1410291158024687232","@type":"Researcher","personIdentifier":[{"@type":"NRID","@value":"9000415350486"}],"foaf:name":[{"@language":"en","@value":"Moroi Satoka"},{"@language":"ja","@value":"諸井 里香"}],"jpcoar:affiliationName":[{"@language":"ja","@value":"昭和大学藤が丘病院放射線技術部"},{"@language":"en","@value":"Department of Radiological Technology, Showa University Fujigaoka Hospital"}]}],"publication":{"publicationIdentifier":[{"@type":"PISSN","@value":"03694305"},{"@type":"EISSN","@value":"18814883"},{"@type":"CODEN","@value":"NIPHAP"},{"@type":"NDL_BIB_ID","@value":"000000018960"},{"@type":"ISSN","@value":"03694305"},{"@type":"LISSN","@value":"03694305"},{"@type":"NCID","@value":"AN00197784"}],"prism:publicationName":[{"@language":"en","@value":"Japanese Journal of Radiological Technology"},{"@language":"ja","@value":"日本放射線技術学会雑誌"},{"@language":"en","@value":"Nippon Hoshasen Gijutsu Gakkai Zasshi"},{"@language":"en","@value":"Jpn. J. Radiol. Technol."},{"@language":"ja","@value":"日放技学誌"}],"dc:publisher":[{"@language":"en","@value":"Japanese Society of Radiological Technology"},{"@language":"ja","@value":"公益社団法人 日本放射線技術学会"}],"prism:publicationDate":"2022-02-20","prism:volume":"78","prism:number":"2","prism:startingPage":"140","prism:endingPage":"151"},"reviewed":"false","dcterms:accessRights":"http://purl.org/coar/access_right/c_abf2","url":[{"@id":"http://id.ndl.go.jp/bib/032015435"},{"@id":"https://ndlsearch.ndl.go.jp/books/R000000004-I032015435"},{"@id":"https://www.jstage.jst.go.jp/article/jjrt/78/2/78_780201/_pdf"},{"@id":"https://search.jamas.or.jp/link/ui/2022111536"}],"availableAt":"2022-02-20","foaf:topic":[{"@id":"https://cir.nii.ac.jp/all?q=computed%20tomography%20(CT)","dc:title":"computed tomography (CT)"},{"@id":"https://cir.nii.ac.jp/all?q=caregiver","dc:title":"caregiver"},{"@id":"https://cir.nii.ac.jp/all?q=radiation%20exposure","dc:title":"radiation exposure"},{"@id":"https://cir.nii.ac.jp/all?q=protective%20curtain","dc:title":"protective curtain"},{"@id":"https://cir.nii.ac.jp/all?q=radiation%20protection","dc:title":"radiation protection"},{"@id":"https://cir.nii.ac.jp/all?q=computed%20tomography%20%EF%BC%88CT%EF%BC%89","dc:title":"computed tomography （CT）"},{"@id":"https://cir.nii.ac.jp/all?q=caregiver","dc:title":"caregiver"},{"@id":"https://cir.nii.ac.jp/all?q=radiation%20exposure","dc:title":"radiation exposure"},{"@id":"https://cir.nii.ac.jp/all?q=protective%20curtain","dc:title":"protective curtain"},{"@id":"https://cir.nii.ac.jp/all?q=radiation%20protection","dc:title":"radiation protection"}],"relatedProduct":[{"@id":"https://cir.nii.ac.jp/crid/1360848658406946944","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Occupational eye dose in interventional cardiology procedures"}]},{"@id":"https://cir.nii.ac.jp/crid/1360869855125281408","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@value":"Relationship between assistant’s lens exposure and dose information during computed tomography examinations"}]},{"@id":"https://cir.nii.ac.jp/crid/1361981470123502336","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"ICRP PUBLICATION 118: ICRP Statement on Tissue Reactions and Early and Late Effects of Radiation in Normal Tissues and Organs — Threshold Doses for Tissue Reactions in a Radiation Protection Context"}]},{"@id":"https://cir.nii.ac.jp/crid/1390001206361789696","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["references"],"jpcoar:relatedTitle":[{"@language":"ja","@value":"ビスマスシートを用いたcomputed tomography fluoroscopyにおける術者被ばくと画質の評価"},{"@language":"en","@value":"Operator Dose Measurements and Image Quality Assessment in Computed Tomography Fluoroscopy Using Bismuth Sheet"},{"@value":"臨床技術 ビスマスシートを用いたcomputed tomography fluoroscopyにおける術者被ばくと画質の評価"},{"@language":"ja-Kana","@value":"リンショウ ギジュツ ビスマスシート オ モチイタ computed tomography fluoroscopy ニ オケル ジュツシャ ヒバク ト ガシツ ノ ヒョウカ"}]},{"@id":"https://cir.nii.ac.jp/crid/1390001206390653184","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@language":"ja","@value":"IVRで使用する天井懸垂型含鉛アクリル防護板と散乱線の相互作用に関する考察"},{"@language":"en","@value":"Interaction between a Ceiling Pendent-type Lead Acrylic Protective Board for Use in IVR and Scattered Radiation"}]},{"@id":"https://cir.nii.ac.jp/crid/1390001206391016192","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["references"],"jpcoar:relatedTitle":[{"@language":"ja","@value":"コリメータカバーを含鉛シートで覆った血管撮影装置における散乱線低減効果の検討"},{"@language":"en","@value":"Investigation of Scattered Radiation Reduction Effect by Use of Collimator Cover Covered with Leaded Sheet in Angiography Equipment"},{"@value":"臨床技術 コリメータカバーを含鉛シートで覆った血管撮影装置における散乱線低減効果の検討"},{"@language":"ja-Kana","@value":"リンショウ ギジュツ コリメータカバー オ ガンエン シート デ オオッタ ケッカン サツエイ ソウチ ニ オケル サンランセン テイゲン コウカ ノ ケントウ"}]},{"@id":"https://cir.nii.ac.jp/crid/1390282679134274944","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@language":"en","@value":"Simultaneous Imaging of Scattered X-ray and Visible Light Using a Hand-made Pinhole Camera"},{"@value":"散乱Ｘ線・可視光同時撮像ピンホールカメラの開発と透視中散乱線の撮像"},{"@language":"ja-Kana","@value":"サンラン Xセン カシコウ ドウジ サツゾウ ピンホールカメラ ノ カイハツ ト トウシ チュウ サンランセン ノ サツゾウ"}]},{"@id":"https://cir.nii.ac.jp/crid/1390282681338560896","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["references"],"jpcoar:relatedTitle":[{"@language":"ja","@value":"X線CTにおける線量評価を目的とした蛍光ガラス線量計の特性および使用方法の検討"},{"@language":"en","@value":"Properties and Usage of Radiophotoluminescent Glass Dosimeters for Computed Tomography Dosimetry"},{"@language":"ja-Kana","@value":"Xセン CT ニ オケル センリョウ ヒョウカ オ モクテキ ト シタ ケイコウ ガラスセンリョウケイ ノ トクセイ オヨビ シヨウ ホウホウ ノ ケントウ"}]},{"@id":"https://cir.nii.ac.jp/crid/1390282681338572032","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@language":"en","@value":"A Study of Operator's Hand and Finger Exposure Dose Reduction During Angiographic Procedures"},{"@language":"ja","@value":"血管撮影時における術者手指被曝線量低減方法に関する検討"},{"@language":"ja-Kana","@value":"ケッカン サツエイジ ニ オケル ジュツシャ シュシ ヒバク センリョウ テイゲン ホウホウ ニ カンスル ケントウ"}]},{"@id":"https://cir.nii.ac.jp/crid/1390575661578873600","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@language":"en","@value":"Measurement of Absorbed Dose in the Air in X-ray CT Examination Rooms Using a Special Protective Shield for CT"},{"@language":"ja","@value":"X線CT検査室におけるCT専用防護板使用時の空気吸収線量測定"},{"@language":"ja-Kana","@value":"Xセン CT ケンサシツ ニ オケル CT センヨウ ボウゴバン シヨウジ ノ クウキ キュウシュウセンリョウ ソクテイ"}]}],"dataSourceIdentifier":[{"@type":"JALC","@value":"oai:japanlinkcenter.org:2009141750"},{"@type":"NDL_SEARCH","@value":"oai:ndlsearch.ndl.go.jp:R000000004-I032015435"},{"@type":"CROSSREF","@value":"10.6009/jjrt.780201"},{"@type":"PUBMED","@value":"35185093"},{"@type":"CIA","@value":"130008161709"},{"@type":"OPENAIRE","@value":"doi_dedup___::d6e9a5877be47a152c55f837efb530b3"},{"@type":"CROSSREF","@value":"10.6009/jjrt.2022-1313_references_DOI_SkX2EUicMYKtnhZGKr75nOtrSfu"},{"@type":"CROSSREF","@value":"10.1088/1361-6498/ad4903_references_DOI_SkX2EUicMYKtnhZGKr75nOtrSfu"}]}