- Integration of CiNii Books functions for fiscal year 2025 has completed
- Trial version of CiNii Research Knowledge Graph Search feature is available on CiNii Labs
- 【Updated on November 26, 2025】Regarding the recording of “Research Data” and “Evidence Data”
- Incorporated Jxiv preprints from JaLC and adding coverage from NDL Search
Postoperative astigmatism errors by two toric intraocular lens calculation formula using anterior segment optical coherence tomography
-
- Kagetsu Riku
- Sato Eye & Internal Medicine Clinic
-
- Tsutsui Kenta
- Sato Eye & Internal Medicine Clinic
-
- Horita Mikiko
- Sato Eye & Internal Medicine Clinic
-
- Ichiki Satoshi
- Sato Eye & Internal Medicine Clinic
-
- Hayashi Minami
- Sato Eye & Internal Medicine Clinic
-
- Koshiyama Takeshi
- Sato Eye & Internal Medicine Clinic
-
- Wakita Miki
- Sato Eye & Internal Medicine Clinic
-
- Osaka Megumi
- Sato Eye & Internal Medicine Clinic
-
- Matsuyama Eri
- Sato Eye & Internal Medicine Clinic
-
- Sato Tomoki
- Sato Eye & Internal Medicine Clinic
-
- Kawaji Takahiro
- Sato Eye & Internal Medicine Clinic
-
- Hayataka Hisako
- Sato Eye & Internal Medicine Clinic
-
- Goto Shinsuke
- Sato Eye & Internal Medicine Clinic
Bibliographic Information
- Other Title
-
- 前眼部OCTを用いた2つのトーリック眼内レンズ計算式による術後乱視誤差の検討
- Published
- 2022
- DOI
-
- 10.4263/jorthoptic.52f119
- Publisher
- JAPANESE ASSOCIATION OF CERTIFIED ORTHOPTISTS
Search this article
Description
<p> 【Purpose】Anterior segment optical coherence tomography (AS-OCT) has two methods for toric intraocular lens (T-IOL) calculation: the Barrett toric formula (BT formula) based on keratomerty (K) and the CASIA2 toric formula (CT formula) based on Fourier real power cylinder (FRCyl). We compared the postoperative astigmatism errors obtained using both formulas.</p><p> 【Subjects and Methods】Subjects were 39 eyes of 39 patients (20 males and 19 females; mean age, 68.8±9.7 years) who were implanted with multifocal T-IOL (ACTIVEFOCUSTM SV25T3-6, Alcon). The T-IOL power was determined using the CT formula in all eyes at the time of surgery. We retrospectively examined the following: 1) comparisons of the preoperative corneal with-the-rule (WTR) and against-the-rule (ATR) astigmatic measurements obtained using the K and FRCyl values, and 2) comparisons of the postoperative astigmatism errors and the percentages of eyes that had achieved a refractive astigmatism error within ±0.50 D and ±1.00 D with both formulas.</p><p> 【Results】The degree of the preoperative corneal ATR astigmatism obtained with FRCyl was significantly higher (p = 0.04). The respective mean postoperative WTR and ATR astigmatism errors were 0.64±0.36 D (the BT formula) and 0.45±0.39 D (the CT formula) (p = 0.18); and 0.37±0.27 D (the BT formula) and 0.36±0.29 D (the CT formula) (p = 0.84). No significant difference was seen between the values obtained by both formulas. The percentages of eyes that had achieved a refractive astigmatism error within ±0.50 D were 66% with both formulas (p = 0.59); and the percentages for those achieving within±1.0 D were 90% with the BT formula and 95% with the CT formula (p = 0.67). No significant difference was seen between these percentages.</p><p> 【Conclusion】The CT formula installed on the AS-OCT showed the same astigmatism correction effect as same as the effect by the BT formula. T-IOL with power calculated using the CT formula installed on the AS-OCT could achieve the same astigmatism correction effect as that using the BT formula.</p>
Journal
-
- JAPANESE ORTHOPTIC JOURNAL
-
JAPANESE ORTHOPTIC JOURNAL 52 (0), 151-158, 2022
JAPANESE ASSOCIATION OF CERTIFIED ORTHOPTISTS
- Tweet
Details 詳細情報について
-
- CRID
- 1390295369737885568
-
- ISSN
- 18839215
- 03875172
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- Crossref
-
- Abstract License Flag
- Disallowed