{"@context":{"@vocab":"https://cir.nii.ac.jp/schema/1.0/","rdfs":"http://www.w3.org/2000/01/rdf-schema#","dc":"http://purl.org/dc/elements/1.1/","dcterms":"http://purl.org/dc/terms/","foaf":"http://xmlns.com/foaf/0.1/","prism":"http://prismstandard.org/namespaces/basic/2.0/","cinii":"http://ci.nii.ac.jp/ns/1.0/","datacite":"https://schema.datacite.org/meta/kernel-4/","ndl":"http://ndl.go.jp/dcndl/terms/","jpcoar":"https://github.com/JPCOAR/schema/blob/master/2.0/"},"@id":"https://cir.nii.ac.jp/crid/1390587675160106368.json","@type":"Article","productIdentifier":[{"identifier":{"@type":"DOI","@value":"10.18948/shasetaikai.2024.06.0_341"}}],"dc:title":[{"@language":"ja","@value":"熱環境シミュレーションとCFDの連成解析によるバイオフィリック建築の熱環境評価"},{"@language":"en","@value":"Hygrothermal Environment Assessment of Biophilic Architecture through Coupled Analysis of Building Energy Simulation and CFD"}],"dc:language":"ja","description":[{"type":"abstract","notation":[{"@language":"ja","@value":"<p>本研究では、バイオフィリック要素としての室内滝・池が設計の最適化に向け、設計段階での精緻な予測・検討を実現させることを目的とした。そのため、熱環境シミュレーションとCFDの連成解析手法を提案し、滝・池を取り入れた空間の熱環境と熱負荷を精緻に予測・検討することが可能となった。また、滝・池を有する空間で最適な温熱環境および省エネルギー性を実現するためには、設計段階での定量的な検討が不可欠であることが検証できた。</p>"}],"abstractLicenseFlag":"disallow"}],"creator":[{"@id":"https://cir.nii.ac.jp/crid/1410587675160106368","@type":"Researcher","foaf:name":[{"@language":"ja","@value":"尾崎 明仁"}],"jpcoar:affiliationName":[{"@language":"ja","@value":"九州大学"}]},{"@id":"https://cir.nii.ac.jp/crid/1410587675160106369","@type":"Researcher","foaf:name":[{"@language":"ja","@value":"YANG Xianzhe"}],"jpcoar:affiliationName":[{"@language":"ja","@value":"九州大学"}]},{"@id":"https://cir.nii.ac.jp/crid/1410587675160106372","@type":"Researcher","foaf:name":[{"@language":"ja","@value":"劉 城準"}],"jpcoar:affiliationName":[{"@language":"ja","@value":"九州大学"}]},{"@id":"https://cir.nii.ac.jp/crid/1410587675160106371","@type":"Researcher","foaf:name":[{"@language":"ja","@value":"有馬 雄祐"}],"jpcoar:affiliationName":[{"@language":"ja","@value":"九州大学"}]},{"@id":"https://cir.nii.ac.jp/crid/1410587675160106374","@type":"Researcher","foaf:name":[{"@language":"ja","@value":"高辻 量"}],"jpcoar:affiliationName":[{"@language":"ja","@value":"日建設計"}]},{"@id":"https://cir.nii.ac.jp/crid/1410587675160106370","@type":"Researcher","foaf:name":[{"@language":"ja","@value":"永瀬 修"}],"jpcoar:affiliationName":[{"@language":"ja","@value":"日建設計"}]},{"@id":"https://cir.nii.ac.jp/crid/1410587675160106373","@type":"Researcher","foaf:name":[{"@language":"ja","@value":"崔 連希"}],"jpcoar:affiliationName":[{"@language":"ja","@value":"九州大学"}]}],"publication":{"publicationIdentifier":[{"@type":"PISSN","@value":"18803806"},{"@type":"EISSN","@value":"24242179"}],"prism:publicationName":[{"@language":"ja","@value":"空気調和・衛生工学会大会　学術講演論文集"},{"@language":"en","@value":"Techinical Papers of Annual Meeting the Society of Heating,Air-conditioning and Sanitary Engineers of Japan"}],"dc:publisher":[{"@language":"en","@value":"The Society of Heating,Air-Conditioning&Sanitary Engineers of Japan"},{"@language":"ja","@value":"公益社団法人 空気調和・衛生工学会"}],"prism:publicationDate":"2024","prism:volume":"2024.06","prism:number":"0","prism:startingPage":"341","prism:endingPage":"344"},"jpcoar:conferenceName":"令和６年度空気調和・衛生工学会大会（佐賀）","availableAt":"2024","foaf:topic":[{"@id":"https://cir.nii.ac.jp/all?q=%E7%86%B1%E7%92%B0%E5%A2%83","dc:title":"熱環境"},{"@id":"https://cir.nii.ac.jp/all?q=CFD","dc:title":"CFD"},{"@id":"https://cir.nii.ac.jp/all?q=%E9%80%A3%E6%88%90%E8%A7%A3%E6%9E%90","dc:title":"連成解析"}],"dataSourceIdentifier":[{"@type":"JALC","@value":"oai:japanlinkcenter.org:2014659177"}]}