{"@context":{"@vocab":"https://cir.nii.ac.jp/schema/1.0/","rdfs":"http://www.w3.org/2000/01/rdf-schema#","dc":"http://purl.org/dc/elements/1.1/","dcterms":"http://purl.org/dc/terms/","foaf":"http://xmlns.com/foaf/0.1/","prism":"http://prismstandard.org/namespaces/basic/2.0/","cinii":"http://ci.nii.ac.jp/ns/1.0/","datacite":"https://schema.datacite.org/meta/kernel-4/","ndl":"http://ndl.go.jp/dcndl/terms/","jpcoar":"https://github.com/JPCOAR/schema/blob/master/2.0/"},"@id":"https://cir.nii.ac.jp/crid/1390587915165946752.json","@type":"Article","productIdentifier":[{"identifier":{"@type":"DOI","@value":"10.1585/pfr.20.1201052"}},{"identifier":{"@type":"URI","@value":"https://www.jstage.jst.go.jp/article/pfr/20/0/20_1201052/_pdf"}}],"dc:title":[{"@language":"en","@value":"Revisit to Cormack Inversion Using Function Modification Technique for Plasma Tomography"}],"dc:language":"en","description":[{"type":"abstract","notation":[{"@language":"en","@value":"<p>The Cormack inversion is a well-known procedure for tomography. However, the Fourier-Bessel function expansion could be preferably used for plasma tomography, since plasma images obtained with the Cormack inversion tend to produce a false plasma image in the boundary without regards to its advantage: the direct structural analysis of plasma is possible using a set of line-integrated data. Here we propose an application of function modification technique to revive the advantage of the Cormack inversion and present successful experimental result in a tomography system of a cylindrical plasma.</p>"}],"abstractLicenseFlag":"disallow"}],"creator":[{"@id":"https://cir.nii.ac.jp/crid/1410587915165946754","@type":"Researcher","foaf:name":[{"@language":"en","@value":"NISHIMURA Yuki"}],"jpcoar:affiliationName":[{"@language":"en","@value":"Interdisciplinary Graduate School of Engineering Science, Kyushu University"}]},{"@id":"https://cir.nii.ac.jp/crid/1410587915165946756","@type":"Researcher","foaf:name":[{"@language":"en","@value":"NAGASHIMA Yoshihiko"}],"jpcoar:affiliationName":[{"@language":"en","@value":"Research Institute for Applied Mechanics, Kyushu University"}]},{"@id":"https://cir.nii.ac.jp/crid/1410587915165946759","@type":"Researcher","foaf:name":[{"@language":"en","@value":"MOON Chanho"}],"jpcoar:affiliationName":[{"@language":"en","@value":"Research Institute for Applied Mechanics, Kyushu University"}]},{"@id":"https://cir.nii.ac.jp/crid/1410587915165946757","@type":"Researcher","foaf:name":[{"@language":"en","@value":"NISHIZAWA Takashi"}],"jpcoar:affiliationName":[{"@language":"en","@value":"Research Institute for Applied Mechanics, Kyushu University"}]},{"@id":"https://cir.nii.ac.jp/crid/1410587915165946762","@type":"Researcher","foaf:name":[{"@language":"en","@value":"KOBAYASHI Taiki"}],"jpcoar:affiliationName":[{"@language":"en","@value":"Research Institute for Applied Mechanics, Kyushu University"}]},{"@id":"https://cir.nii.ac.jp/crid/1410587915165946758","@type":"Researcher","foaf:name":[{"@language":"en","@value":"KASUYA Naohiro"}],"jpcoar:affiliationName":[{"@language":"en","@value":"Research Institute for Applied Mechanics, Kyushu University"}]},{"@id":"https://cir.nii.ac.jp/crid/1410587915165946755","@type":"Researcher","foaf:name":[{"@language":"en","@value":"KOBAYASHI Tatsuya"}],"jpcoar:affiliationName":[{"@language":"en","@value":"Research Institute for Applied Mechanics, Kyushu University"},{"@language":"en","@value":"National Institute for Fusion Science, National Institutes of Natural Sciences"}]},{"@id":"https://cir.nii.ac.jp/crid/1410587915165946760","@type":"Researcher","foaf:name":[{"@language":"en","@value":"FUJISAWA Akihide"}],"jpcoar:affiliationName":[{"@language":"en","@value":"Research Institute for Applied Mechanics, Kyushu University"}]},{"@id":"https://cir.nii.ac.jp/crid/1410587915165946761","@type":"Researcher","foaf:name":[{"@language":"en","@value":"TOKUZAWA Tokihiko"}],"jpcoar:affiliationName":[{"@language":"en","@value":"Research Institute for Applied Mechanics, Kyushu University"},{"@language":"en","@value":"National Institute for Fusion Science, National Institutes of Natural Sciences"}]},{"@id":"https://cir.nii.ac.jp/crid/1410587915165946753","@type":"Researcher","foaf:name":[{"@language":"en","@value":"IDO Takeshi"}],"jpcoar:affiliationName":[{"@language":"en","@value":"Research Institute for Applied Mechanics, Kyushu University"},{"@language":"en","@value":"National Institute for Fusion Science, National Institutes of Natural Sciences"}]},{"@id":"https://cir.nii.ac.jp/crid/1410587915165946752","@type":"Researcher","foaf:name":[{"@language":"en","@value":"SHIMIZU Akihiro"}],"jpcoar:affiliationName":[{"@language":"en","@value":"Research Institute for Applied Mechanics, Kyushu University"},{"@language":"en","@value":"National Institute for Fusion Science, National Institutes of Natural Sciences"}]}],"publication":{"publicationIdentifier":[{"@type":"EISSN","@value":"18806821"},{"@type":"LISSN","@value":"18806821"}],"prism:publicationName":[{"@language":"en","@value":"Plasma and Fusion Research"},{"@language":"en","@value":"Plasma and Fusion Research"}],"dc:publisher":[{"@language":"en","@value":"The Japan Society of Plasma Science and Nuclear Fusion Research"},{"@language":"ja","@value":"一般社団法人 プラズマ・核融合学会"}],"prism:publicationDate":"2025","prism:volume":"20","prism:number":"0","prism:startingPage":"n/a"},"reviewed":"false","url":[{"@id":"https://www.jstage.jst.go.jp/article/pfr/20/0/20_1201052/_pdf"}],"availableAt":"2025","foaf:topic":[{"@id":"https://cir.nii.ac.jp/all?q=plasma%20diagnostics","dc:title":"plasma diagnostics"},{"@id":"https://cir.nii.ac.jp/all?q=tomography","dc:title":"tomography"},{"@id":"https://cir.nii.ac.jp/all?q=Cormack%20inversion","dc:title":"Cormack inversion"},{"@id":"https://cir.nii.ac.jp/all?q=image%20reconstruction","dc:title":"image reconstruction"},{"@id":"https://cir.nii.ac.jp/all?q=Fourier-Zernike%20function","dc:title":"Fourier-Zernike function"}],"relatedProduct":[{"@id":"https://cir.nii.ac.jp/crid/1360011144699446912","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Tomography of <i>m</i>=1 mode structure in tokamak plasma using least-square-fitting method and Fourier–Bessel expansions"}]},{"@id":"https://cir.nii.ac.jp/crid/1360285709385465088","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Tomography as a promising diagnostic tool for plasma turbulence"}]},{"@id":"https://cir.nii.ac.jp/crid/1362825895688649088","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Representation of a Function by Its Line Integrals, with Some Radiological Applications. II"}]},{"@id":"https://cir.nii.ac.jp/crid/1390581148797213056","@type":"Article","resourceType":"学術雑誌論文(journal article)","relationType":["references"],"jpcoar:relatedTitle":[{"@language":"en","@value":"A Method to Analyze Plasma Images Using Modified Fourier-Bessel Functions"}]}],"dataSourceIdentifier":[{"@type":"JALC","@value":"oai:japanlinkcenter.org:2014824440"},{"@type":"CROSSREF","@value":"10.1585/pfr.20.1201052"}]}