{"@context":{"@vocab":"https://cir.nii.ac.jp/schema/1.0/","rdfs":"http://www.w3.org/2000/01/rdf-schema#","dc":"http://purl.org/dc/elements/1.1/","dcterms":"http://purl.org/dc/terms/","foaf":"http://xmlns.com/foaf/0.1/","prism":"http://prismstandard.org/namespaces/basic/2.0/","cinii":"http://ci.nii.ac.jp/ns/1.0/","datacite":"https://schema.datacite.org/meta/kernel-4/","ndl":"http://ndl.go.jp/dcndl/terms/","jpcoar":"https://github.com/JPCOAR/schema/blob/master/2.0/"},"@id":"https://cir.nii.ac.jp/crid/1390862776828076288.json","@type":"Article","productIdentifier":[{"identifier":{"@type":"DOI","@value":"10.1299/mej.23-00461"}},{"identifier":{"@type":"URI","@value":"https://www.jstage.jst.go.jp/article/mej/11/2/11_23-00461/_pdf"}}],"dc:title":[{"@language":"en","@value":"Overview of development program for engineering scale extraction chromatography MA(III) recovery system"}],"dc:language":"en","description":[{"type":"abstract","notation":[{"@language":"en","@value":"<p>Japan Atomic Energy Agency is developing extraction chromatography technology to recover MA(III) from spent nuclear fuel. Developments in the extraction chromatography system especially focusing on safety and stable operation are required for practical application of the technology. This paper discusses the main tasks that have to be challenged preferentially based on achievements obtained by previous studies and potential MA(III) recovery process flow. For the safety assessment, removal of fine particles, optimization in adsorbent for a reduction in pressure drop of the column, degradation behavior of the adsorbents, and recycling of the adsorbents are topics for development. Enhancement in resistance against radiation and acid of material in pump and development of automated operation system is required to maintain product quality during long time operation. Those studies are carried out simultaneously in a research project of 2019-2024, and new technologies such as a filter with porous media, porous adsorbents for low-pressure drop column, used adsorbent recycling, radiation resistant pump, and automated valve switching system using online analysis are developed in this project. A demonstration of the total system with a large-scale apparatus will be carried out at the end of the project.</p>"}],"abstractLicenseFlag":"disallow"}],"creator":[{"@id":"https://cir.nii.ac.jp/crid/1410862776828076290","@type":"Researcher","foaf:name":[{"@language":"en","@value":"WATANABE Sou"}],"jpcoar:affiliationName":[{"@language":"en","@value":"Japan Atomic Energy Agency"}]},{"@id":"https://cir.nii.ac.jp/crid/1410862776828076289","@type":"Researcher","foaf:name":[{"@language":"en","@value":"GOTO Ichiro"}],"jpcoar:affiliationName":[{"@language":"en","@value":"Japan Atomic Energy Agency"}]},{"@id":"https://cir.nii.ac.jp/crid/1410862776828076295","@type":"Researcher","foaf:name":[{"@language":"en","@value":"MIYAZAKI Yasunori"}],"jpcoar:affiliationName":[{"@language":"en","@value":"Japan Atomic Energy Agency"}]},{"@id":"https://cir.nii.ac.jp/crid/1410862776828076294","@type":"Researcher","foaf:name":[{"@language":"en","@value":"HASEGAWA Kenta"}],"jpcoar:affiliationName":[{"@language":"en","@value":"Japan Atomic Energy Agency"}]},{"@id":"https://cir.nii.ac.jp/crid/1410862776828076293","@type":"Researcher","foaf:name":[{"@language":"en","@value":"TAKEUCHI Masayuki"}],"jpcoar:affiliationName":[{"@language":"en","@value":"Japan Atomic Energy Agency"}]},{"@id":"https://cir.nii.ac.jp/crid/1410862776828076291","@type":"Researcher","foaf:name":[{"@language":"en","@value":"WATANABE Masayuki"}],"jpcoar:affiliationName":[{"@language":"en","@value":"Japan Atomic Energy Agency"}]},{"@id":"https://cir.nii.ac.jp/crid/1410862776828076288","@type":"Researcher","foaf:name":[{"@language":"en","@value":"TAKAHATAKE Youko"}],"jpcoar:affiliationName":[{"@language":"en","@value":"Japan Atomic Energy Agency"}]},{"@id":"https://cir.nii.ac.jp/crid/1410862776828076292","@type":"Researcher","foaf:name":[{"@language":"en","@value":"SANO Yuichi"}],"jpcoar:affiliationName":[{"@language":"en","@value":"Japan Atomic Energy Agency"}]}],"publication":{"publicationIdentifier":[{"@type":"EISSN","@value":"21879745"}],"prism:publicationName":[{"@language":"en","@value":"Mechanical Engineering Journal"},{"@language":"ja","@value":"Mechanical Engineering Journal"}],"dc:publisher":[{"@language":"en","@value":"The Japan Society of Mechanical Engineers"},{"@language":"ja","@value":"一般社団法人 日本機械学会"}],"prism:publicationDate":"2024","prism:volume":"11","prism:number":"2","prism:startingPage":"23-00461","prism:endingPage":"23-00461"},"reviewed":"false","url":[{"@id":"https://www.jstage.jst.go.jp/article/mej/11/2/11_23-00461/_pdf"}],"availableAt":"2024","foaf:topic":[{"@id":"https://cir.nii.ac.jp/all?q=Extraction%20chromatography","dc:title":"Extraction chromatography"},{"@id":"https://cir.nii.ac.jp/all?q=Minor%20actinide%20recovery","dc:title":"Minor actinide recovery"},{"@id":"https://cir.nii.ac.jp/all?q=Engineering%20scale%20system","dc:title":"Engineering scale system"},{"@id":"https://cir.nii.ac.jp/all?q=Safety%20assessment","dc:title":"Safety assessment"},{"@id":"https://cir.nii.ac.jp/all?q=Stable%20operation","dc:title":"Stable operation"}],"relatedProduct":[{"@id":"https://cir.nii.ac.jp/crid/1050001337572212096","@type":"Article","resourceType":"会議発表資料(conference paper)","relationType":["references"],"jpcoar:relatedTitle":[{"@language":"en","@value":"Flow-sheet study of MA recovery by extraction chromatography for SmART cycle project"},{"@language":"ja","@value":"SmARTサイクル研究のためのMA回収フローシートの開発"}]},{"@id":"https://cir.nii.ac.jp/crid/1360011143846984192","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Am, Cm recovery from genuine HLLW by extraction chromatography"}]},{"@id":"https://cir.nii.ac.jp/crid/1360017981409362560","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Improvement in flow-sheet of extraction chromatography for trivalent minor actinides recovery"}]},{"@id":"https://cir.nii.ac.jp/crid/1360574094872801536","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Chromatography Column System With Controlled Flow and Temperature for Engineering Scale Application"}]},{"@id":"https://cir.nii.ac.jp/crid/1360574095158544768","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Extraction Chromatography Experiments on Repeated Operation using Engineering Scale Column System"}]},{"@id":"https://cir.nii.ac.jp/crid/1360580932840778368","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Development of MA separation process with TEHDGA/SiO2-P for an advanced reprocessing"}]},{"@id":"https://cir.nii.ac.jp/crid/1360861295469486336","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Design of MA(III)/Ln(III) separation process of extraction chromatography technology"}]},{"@id":"https://cir.nii.ac.jp/crid/1362262944153163904","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Separation of actinides from spent nuclear fuel: A review"}]},{"@id":"https://cir.nii.ac.jp/crid/1362544418611415424","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Safety operation of chromatography column system with discharging hydrogen radiolytically generated"}]},{"@id":"https://cir.nii.ac.jp/crid/1362825894219955968","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Optimizing composition of TODGA/SiO2-P adsorbent for extraction chromatography process"}]},{"@id":"https://cir.nii.ac.jp/crid/1363670318935252864","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Microanalysis of silica-based adsorbent for effective recovery of radioactive elements"}]},{"@id":"https://cir.nii.ac.jp/crid/1363951795585538176","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@value":"Novel Extraction of Chromatographic Resins Based on Tetraalkyldiglycolamides: Characterization and Potential Applications"}]},{"@id":"https://cir.nii.ac.jp/crid/1390282679565256064","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@language":"en","@value":"Novel Soft–Hard Donor Ligand, NTAamide, for Mutual Separation of Trivalent Actinoids and Lanthanoids"}]},{"@id":"https://cir.nii.ac.jp/crid/1390282680163143808","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@language":"en","@value":"Experimental Study on the Basic Characteristics of a Novel Silica-Based CMPO Adsorbent"},{"@language":"ja","@value":"378. シリカ担持型CMPO吸着材の基礎特性に関する試験研究"}]},{"@id":"https://cir.nii.ac.jp/crid/1390305953579238400","@type":"Article","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@language":"en","@value":"Development of a Quantitative, Radiation-Resistant Feeding Pump for Use in Extraction Chromatography Techniques for MA(III) Recovery"}]},{"@id":"https://cir.nii.ac.jp/crid/1390564238024283392","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@language":"en","@value":"Selective Sc Recovery from Rare Earths in Nitric Acid Medium by Extraction Chromatography"}]},{"@id":"https://cir.nii.ac.jp/crid/1390845713050550528","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@language":"en","@value":"Influences of Pore and Particle Sizes of CMPO/SiO<sub>2</sub>-P Adsorbent on Extraction Chromatography Process"},{"@value":"Influences of Pore and Particle Sizes of CMPO/SiO2-P Adsorbent on Extraction Chromatography Process"}]},{"@id":"https://cir.nii.ac.jp/crid/1390845713053085056","@type":"Article","relationType":["references"],"jpcoar:relatedTitle":[{"@language":"en","@value":"Characteristics of TPDN/SiO2-P adsorbent for MA(III) recovery"}]},{"@id":"https://cir.nii.ac.jp/crid/1390868903532658432","@type":"Article","relationType":["isReferencedBy"],"jpcoar:relatedTitle":[{"@language":"en","@value":"Safety Improvement in the Packed Column of Extraction Chromatography System for Trivalent Minor Actinides Recovery"}]}],"dataSourceIdentifier":[{"@type":"JALC","@value":"oai:japanlinkcenter.org:2012732010"},{"@type":"CROSSREF","@value":"10.1299/mej.23-00461"},{"@type":"CROSSREF","@value":"10.15669/pnst.8.248_references_DOI_YA1PkyO5kybDvrV21qG3IahJNge"},{"@type":"CROSSREF","@value":"10.15669/pnst.8.238_references_DOI_YA1PkyO5kybDvrV21qG3IahJNge"}]}