角形鋼管側柱を対象とする外ダイアフラム形式梁フランジ接合部の耐力算定に関する研究
書誌事項
- タイトル別名
-
- Study on Strength Calculation of Beam-Flange to Rectangular Hollow Section Side Column Connections with Exterior Diaphragm
- 公開日
- 2025-01-15
- 資源種別
- departmental bulletin paper
- DOI
-
- 10.15017/7337586
- 公開者
- 九州大学大学院人間環境学研究院都市・建築学部門
この論文をさがす
説明
By utilizing FEM analysis on monotonic tensile experiments, this study analyzed on the behavior of beam-torectangular hollow section (RHS) side column connections with exterior diaphragms. This article reevaluates the plastic and yield strength of this kind of connections with a new formular basing on a suggested formular for connections on interior columns, of which the aim is to enhance accuracy in strength prediction and address recent discoveries in connections’ mechanical behavior. Meanwhile an approximate formular is also given. Comparing Matsuo's traditional method to the new approach reveals, the latter showed a superior accuracy and safety, giving lower estimates on yield strength and plastic strength, according to a static analysis.