Fume Generation in Al-Mg Alloy Welding with AC-pulsed GMA Welding Method

この論文をさがす

抄録

A novel AC-pulsed GMA inverter welder has been developed to reduce the weld fumes, generated from the overheated droplets of filler metal wire, which contain high vapor pressure alloying elements. In the fume collection experiment with our new welder, the effects of alloying, components both in solid wire and base metal on fume generation have been studied with different combinations of welding materials. We have found that Mg in the wire is the main fume generation source in DCEP-pulsed GMA welding of an Al-Mg alloy, and our AC-pulsed GMA inverter welder can suppress its effect satisfactorily. The effects of welding parameters (welding current, arc voltage, etc.) on fume generation have also been investigated. X-ray diffraction has been used to identify the compositions of fumes collected under different welding conditions. After observing droplet transfer with an ultra-high speed video camera, fume generating phenomena and mechanisms of fume suppression are discussed.

収録刊行物

被引用文献 (1)*注記

もっと見る

詳細情報 詳細情報について

  • CRID
    1570009752371940864
  • NII論文ID
    110006487049
  • NII書誌ID
    AA00867058
  • ISSN
    03874508
  • 本文言語コード
    en
  • データソース種別
    • CiNii Articles

問題の指摘

ページトップへ