Use of Leaky Coaxial cable (LCX) of a VHF/UHF antenna is proposed to monitor intensity of heavy rains along the cable in real time. Using a pair of LCXs with a transmitting antenna and a receiving antenna installed in parallel each other, receiving signals at arbitrary locations along LCX can be determined. For quantitative evaluation between rainfall intensity and the LCX signals, an artificial rainfall experiment was conducted. The LCX signal was nonstationary, and a component of fluctuation due to rainfall was below a noise floor. For denoising, a multiresolution analysis using a Daubechies wavelet was applied to the signals. As a result, the component of the fluctuation due to rainfall was extracted, and one-minute rainfall intensity of the artificial heavy rains was detected successfully. Conducting a field rainfall experiment using the dual LCX system as well, real heavy rains were also detected from a noisy signal using MRA.