Seroma Formation Associated with Expanded Polytetrafluoroethylene Graft Used for Dialysis Access : A Case Report

HANDLE Web Site Open Access

Bibliographic Information

Other Title
  • 透析用ePTFEグラフトに生じた血清腫の1例
  • トウセキヨウ ePTFE グラフト ニ ショウジタ ケッセイ シュ ノ 1レイ

Search this article

Abstract

The patient was a 67-year-old man with end stage renal failure. Hemodialysis had been started in 1998. An expanded polytetrafluoroethylene (PTFE) graft was inserted into his left forearm and used for vascular access. He received a partial replacement of the expanded PTFE graft in September 2013. A seroma formed after this intervention and subsequently grew larger. He thus underwent seroma removal and bypass graft surgery. Four months after the surgery, to date, he remains free of seroma recurrence.