Seroma Formation Associated with Expanded Polytetrafluoroethylene Graft Used for Dialysis Access : A Case Report
-
- Sasaki, Yutaro
- The Department of Urology, Ehime Prefecture Central Hospital
-
- Shiozaki, Keito
- The Department of Urology, Ehime Prefecture Central Hospital
-
- Ozaki, Keisuke
- The Department of Urology, Ehime Prefecture Central Hospital
-
- Iio, Hiroyuki
- The Department of Urology, Ehime Prefecture Central Hospital
-
- Oda, Shimpei
- The Department of Urology, Ehime Prefecture Central Hospital
-
- Fujikata, Shiro
- The Department of Urology, Ehime Prefecture Central Hospital
-
- Kan, Masaharu
- The Department of Urology, Ehime Prefecture Central Hospital
Bibliographic Information
- Other Title
-
- 透析用ePTFEグラフトに生じた血清腫の1例
- トウセキヨウ ePTFE グラフト ニ ショウジタ ケッセイ シュ ノ 1レイ
Search this article
Abstract
The patient was a 67-year-old man with end stage renal failure. Hemodialysis had been started in 1998. An expanded polytetrafluoroethylene (PTFE) graft was inserted into his left forearm and used for vascular access. He received a partial replacement of the expanded PTFE graft in September 2013. A seroma formed after this intervention and subsequently grew larger. He thus underwent seroma removal and bypass graft surgery. Four months after the surgery, to date, he remains free of seroma recurrence.
Journal
-
- Hinyokika Kiyo
-
Hinyokika Kiyo 60 (10), 489-491, 2014-10
泌尿器科紀要刊行会
- Tweet
Keywords
Details 詳細情報について
-
- CRID
- 1050001335797014272
-
- NII Article ID
- 120005511058
-
- NII Book ID
- AN00208315
-
- ISSN
- 00181994
-
- HANDLE
- 2433/191174
-
- NDL BIB ID
- 025870638
-
- Text Lang
- ja
-
- Article Type
- departmental bulletin paper
-
- Data Source
-
- IRDB
- NDL
- CiNii Articles