- 【Updated on May 12, 2025】 Integration of CiNii Dissertations and CiNii Books into CiNii Research
- Trial version of CiNii Research Knowledge Graph Search feature is available on CiNii Labs
- 【Updated on June 30, 2025】Suspension and deletion of data provided by Nikkei BP
- Regarding the recording of “Research Data” and “Evidence Data”
Cause of apical thinning on attenuation-corrected myocardial perfusion SPECT
Search this article
Description
Objectives: Decreases in apical and apex activities - namely, 'apical thinning' - are a well-known phenomenon in attenuation-corrected (AC) myocardial perfusion. The aim of this study was to compare actual myocardial thickness derived from a multidetector-row computed tomography with AC myocardial perfusion count from a hybrid single-photon emission computed tomography/computed tomography to investigate the cause of apical thinning. Methods: We enrolled 21 participants with a low likelihood of coronary artery disease (mean age 65±21 years, 13 men) from 185 consecutive patients and 11 healthy volunteers, who independently underwent Tc-sestamibi single-photon emission computed tomography/computed tomography and 64-slice multidetector-row computed tomography scans. AC and non-AC myocardial perfusion counts and thickness were measured on the basis of a 17-segment model and averaged at the apex, apical, mid, and basal walls. Results: Myocardial thickness at the apex was significantly thinner than that at the apical and mid walls (5.1±1.3, 7.3±1.3, and 9.9±2.4 mm, respectively; P<0.005). AC count at the apex was significantly lower than that at the apical and mid regions (76.0±5.5, 82.8±4.7, and 85.6±3.8, respectively; P<0.002). Moderate relationship was observed between myocardial thickness and AC count (y=-10.5+0.22x, r=0.54, P<0.0001. No relationship was found between thickness and non-AC count (r=0.16, P=0.263). Conclusion: The low apex and apical counts were caused by anatomical thinning of the myocardium in AC myocardial perfusion imaging. Attenuation correction provided an accurate relationship between myocardial count and thickness because of the partial volume effect. © 2011 Wolters Kluwer Health | Lippincott Williams and Wilkins.
Journal
-
- Nuclear Medicine Communications
-
Nuclear Medicine Communications 32 (11), 1039-, 2011-11-01
Lippincott, Williams & Wilkins
- Tweet
Keywords
- Aged, 80 and over
- Male
- Technetium Tc 99m Sestamibi
- Tomography, Emission-Computed, Single-Photon
- Myocardial Perfusion Imaging
- Coronary Artery Disease
- Middle Aged
- Image Enhancement
- Sensitivity and Specificity
- Multidetector Computed Tomography
- Image Processing, Computer-Assisted
- Humans
- Female
- Radiopharmaceuticals
- Artifacts
- Algorithms
- Aged
Details 詳細情報について
-
- CRID
- 1050001335950834304
-
- NII Article ID
- 120003518404
-
- NII Book ID
- AA10624879
-
- ISSN
- 01433636
-
- HANDLE
- 2297/29526
-
- PubMed
- 21904268
-
- Text Lang
- en
-
- Article Type
- journal article
-
- Data Source
-
- IRDB
- Crossref
- CiNii Articles
- KAKEN
- OpenAIRE