書誌事項
- タイトル別名
-
- タンケッショウ NaCl ノ チョクリュウ デンキ テイコウ ト シツド ノ
- Relationships between the d.c. Electric Resistance of NaCl Single Crystal and Relative Humidity
この論文をさがす
抄録
application/pdf
The purpose of the present work is to develope the low electric resistance sensor for humidity measurement, because now the hygrometers of electric resistance type have been using the very high electric resistance sensors, and then are very expensive. The d.c. electric resistances of NaCl single crystals were measured by low cost ohmmeter through the electrodes attached on the surfaces of both sides of the creaved NaCl single crystals. The cleaved surfaces have the area of 7.7×7.7 mm^2, and the thickness of crystal was from 1.4 to 5.2 mm. The electrode materials used in this work were nickel, stainless steel and carbon. The measured values of the d.c. electric resistance of NaCl single crystal of 3.1 mm thick ranged between 2 MΩ and 50 KΩ over the range of relative humidities from 45% to 90%. These values did not change for three kinds of electrode materials ; Ni, stainless steel and C.
収録刊行物
-
- 北見工業大学研究報告
-
北見工業大学研究報告 9 (1), 85-89, 1977-11
北見工業大学
- Tweet
詳細情報 詳細情報について
-
- CRID
- 1050001338807001216
-
- NII論文ID
- 120000786511
-
- NII書誌ID
- AN00052475
-
- ISSN
- 03877035
-
- NDL書誌ID
- 1915111
-
- 本文言語コード
- ja
-
- 資料種別
- departmental bulletin paper
-
- データソース種別
-
- IRDB
- NDL
- CiNii Articles