Adaptive Dead-Time Compensation Strategy for Permanent Magnet Synchronous Motor Drive

この論文をさがす

説明

This paper presents an adaptive dead-time compensation strategy to obtain fundamental phase voltage for inverter-fed vector-controlled permanent magnet synchronous motor drives. A phase dead-time compensation voltage (DTCV) to compensate the disturbance voltage due to undesirable characteristics of inverter, such as dead time, turn on/off time of switching devices, and on-voltages of switching devices and diode, is transformed into q-axis DTCV in the rotor reference frame. The relationship between q-axis DTCV and a dead-time compensation time (DTCT) is investigated. DTCT is identified online by using q-axis disturbance voltage, which is estimated by a disturbance observer. The amplitude of phase DTCV is adaptively determined according to the identified DTCT. The accuracy of identified DTCT is experimentally confirmed by calculating the mean absolute percentage error (MAPE) between calculated active power and measured one. MAPE for adaptive DTCT is within 5% at any operating point and is less than that for the fixed DTCT.

論文

収録刊行物

詳細情報 詳細情報について

問題の指摘

ページトップへ