- 【Updated on May 12, 2025】 Integration of CiNii Dissertations and CiNii Books into CiNii Research
- Trial version of CiNii Research Knowledge Graph Search feature is available on CiNii Labs
- 【Updated on June 30, 2025】Suspension and deletion of data provided by Nikkei BP
- Regarding the recording of “Research Data” and “Evidence Data”
Bibliographic Information
- Other Title
-
- フレッシュコンクリート中の塩化物イオン量の簡易測定
- フレッシュコンクリート チュウ ノ エンカブツ イオンリョウ ノ カンイ ソクテイ
Search this article
Description
A simple measurement of chloride ion content in fresh concrete using a silver-silver chloride electrode was investigated. The salinity sensor was used to measure the amount of chloride ions in mortar, focusing on the influence of the time limit for unloading and bleeding of ready-mixed concrete. As a result, the following conclusions were obtained. (1) Within the unloading time limit of ready-mixed concrete, the measurement results of the chloride ion content in mortar by the salt sensor are almost unchanged. (2) Mortar bleeding has little effect on the measurement of chloride ion content by the salt sensor.( 3) Measurement accuracy of chloride ion content in fresh mortar by salinity sensor is about +/−10%.
Journal
-
- JOURNAL OF OSAKA SANGYO UNIVERSITY Natural Sciences
-
JOURNAL OF OSAKA SANGYO UNIVERSITY Natural Sciences 133 17-25, 2023-03-31
大阪産業大学学会
- Tweet
Details 詳細情報について
-
- CRID
- 1050014648078707712
-
- NII Book ID
- AN0002870X
-
- ISSN
- 02871394
-
- NDL BIB ID
- 032838362
-
- Text Lang
- ja
-
- Article Type
- departmental bulletin paper
-
- Data Source
-
- IRDB
- NDL Search