Quasi-stable temperature of the steady state of microwave heated hematite
この論文をさがす
説明
Microwave heated materials often reach a quasi-stable temperature resulting in thermal runaway. To control steady state in microwave processing, it is important to predict the quasi-stable temperature of the steady state. We demonstrated that the microwave heating behavior of hematite varies significantly with its initial temperature. In microwave heating, hematite samples could not be heated from room temperature, whereas hematite samples preheated to 410 °C or higher was heated to a temperature of 1020 °C. The microwave heating behavior can be accurately predicted by considering the steady-state energy balance.
収録刊行物
-
- Chemical Engineering and Processing: Process Intensification
-
Chemical Engineering and Processing: Process Intensification 76 1-5, 2014-02
Elsevier B.V.
- Tweet
詳細情報 詳細情報について
-
- CRID
- 1050564285742215168
-
- NII論文ID
- 120005399096
-
- NII書誌ID
- AA10511464
-
- ISSN
- 02552701
-
- HANDLE
- 2433/185143
-
- 本文言語コード
- en
-
- 資料種別
- journal article
-
- データソース種別
-
- IRDB
- Crossref
- CiNii Articles
- OpenAIRE