極低比速度セミオープン羽根車の内部流れに関する研究

Bibliographic Information

Other Title
  • キョクテイヒ ソクド セミオープン ハネグルマ ノ ナイブ ナガレ ニ カンスル ケンキュウ
  • Internal Flow Characteristics of a Very Low Specific-Speed Semi-Open Impeller

Search this article

Abstract

In the range of very low specific-speed (ns≦100 [m, m3/min, rpm]), performance of a centrifugal pump is much different from that of a normal ns pump. In order to obtain a basic knowledge of pump performance, the internal flow in a semi-open impeller is measured by PIV method and calculated by a commercial CFD code. The results show that strong reverse flow at an impeller outlet is formed and reduces tangential velocity of the absolute flow at an impeller outlet. In the case of β2=90°impeller, a large vortex is formed in the impeller passage at partial flow rate and causes a performance instability. The reverse flow at an impeller outlet brings low angular momentum into an impeller and causes a sharp drop of tangential velocity just before the impeller outlet, which results in a increase of slip factor in the case of β2=30°impeller.

Journal

  • ターボ機械

    ターボ機械 31 (1), 43-52, 2003-01

    日本工業出版

Citations (2)*help

See more

References(15)*help

See more

Details 詳細情報について

Report a problem

Back to top