- 【Updated on May 12, 2025】 Integration of CiNii Dissertations and CiNii Books into CiNii Research
- Trial version of CiNii Research Knowledge Graph Search feature is available on CiNii Labs
- 【Updated on June 30, 2025】Suspension and deletion of data provided by Nikkei BP
- Regarding the recording of “Research Data” and “Evidence Data”
Mechanical properties of a new thermally deformable mitral valve annuloplasty ring and its effects on the mitral valve
Search this article
Description
Ideally, an annuloplasty ring's shape should be changed intraoperatively if mitral valve repair is unsuccessful because of a short coaptation length or systolic anterior motion. Several post-implantation adjustable rings have been developed, but they are not freely deformable and are unsuitable for asymmetric repair of the valvular annulus. We developed a novel thermally deformable mitral annuloplasty ring to address these problems and assessed the ring's mechanical properties and its effect on the mitral valve anatomy. This ring was made of polycaprolactone. Tensile and bending tests were performed to evaluate the ring's mechanical properties. The ratio of the transverse and septal-lateral length was determined as 4:3. Using 10 pig hearts, we measured the post-deformation coaptation length and minimum distance from the coaptation to the ventricular septum, which is a factor of abnormal systolic anterior motion of the mitral valve. In the mechanical tests, the ring's yield point was greater than the deformation force of the annulus in humans. In pigs with deformation from 4:3 to 4:2, the coaptation length was significantly increased in each mitral valve part. In pigs with deformation from 4:3 to 4:4, the minimum distance from the coaptation to the ventricular septum was significantly increased. Asymmetrical ring deformation increased the coaptation length only at the deformed area. In conclusion, this new thermally deformable mitral annuloplasty ring could be order-made to effectively change the coaptation length in all parts of the mitral valve and the distance from the coaptation to septum post-deformation via intraoperative heating.
Journal
-
- Journal of artificial organs
-
Journal of artificial organs 22 (2), 126-133, 2019-06
Springer
- Tweet
Details 詳細情報について
-
- CRID
- 1050848249730236544
-
- NII Article ID
- 120006847759
-
- ISSN
- 16190904
- 14347229
-
- HANDLE
- 2115/78253
-
- PubMed
- 30456661
-
- Text Lang
- en
-
- Article Type
- journal article
-
- Data Source
-
- IRDB
- Crossref
- CiNii Articles
- KAKEN
- OpenAIRE