書誌事項
- タイトル別名
-
- Hadamard Transform X-ray Telescope〔邦文〕
- Hadamard Transform X ray Telescope ホウブン
- Hadamard Transform X-ray Telescope
この論文をさがす
説明
The characteristics of the Hadamard transform x-ray telescope (HTXT) are investigated theoretically and experimentally. Comparing its characteristics with a pin hole camera with the same detector area, the signal to noise ratio is better in the case that spurious counts are predominant over the counts due to x-ray image. If the positional resolution of the position sensitive detector is poor, the reconstructed image is obscurred by just the same amount as the image that would be obtained by the pin hole camera with the same position sensitive detector. In the case that some parts of the detector mulfunctioned and some data are lost, X-ray image can be reconstructed by substituting the mean value of the observed data to the lost data. Even if an x-ray image can not be seen by some part of the detector, the x-ray image can be reconstructed by usual Hadamard transformation method. An Hadamard transform x-ray telescope is constructed and its operational features are investigated experimentally. The Hadamard mask is made by the photo etching technique. The rise time method proposed by Borkowski and Kopp is employed to get the positional information from the multiwire proportional counter. The HTXT functioned well and the results show the validity of this telescope in x-ray astronomy.
資料番号: SA0125781000
収録刊行物
-
- 東京大学宇宙航空研究所報告
-
東京大学宇宙航空研究所報告 15 (3_B), 585-610, 1979-10
東京大学宇宙航空研究所
- Tweet
詳細情報 詳細情報について
-
- CRID
- 1050848249891645440
-
- NII論文ID
- 110000197436
-
- NII書誌ID
- AN00161914
-
- ISSN
- 05638100
-
- NDL書誌ID
- 2160777
-
- 本文言語コード
- ja
-
- 資料種別
- departmental bulletin paper
-
- データソース種別
-
- IRDB
- NDLサーチ
- CiNii Articles