Earthquake damage evaluation of wooden framed structures by shaking table and static loading tests
Bibliographic Information
- Other Title
-
- 振動台加振ならびに静的載荷実験による木造軸組架構の地震時損傷評価
- シンドウダイカシン ナラビニ セイテキサイカ ジッケン ニ ヨル モクゾウジクグミカコウ ノ ジシンジ ソンショウ ヒョウカ
Search this article
Description
Shaking table test of wooden framed structure was conducted under light,moderate or heavy dead load. The dead weight to wooden fame was changed for 2.0kN/㎡,4.0kN/㎡,or 5.9kN/㎡,and the maximum acceleration level of the input earthquake excitation was increased from 200cm/s^2 to 2,000cm/s^2 gradually. Fundamental dynamic behavior of one-story,one-bay wooden frame with or without braces and/or plywood panel walls was investigated. The influence on a natural period and a response magnification of the structure is focused. Moreover,the effect due to vertical vibrations (up and down) and specifications of beam-to-column joint connectors are also considered. In conclusions,the following were clarified. Natural period of the elasticity limit,Te,of wooden framed structure was proposed as an evaluation index of damage at the earthquake. It is defined as the structural damage in plasticity when the natural period exceeds Te. Executing the static loading test,a natural period ofthe elasticity limit,Te,was calculated using equivalent elasticity rigidity.
Journal
-
- 広島工業大学紀要. 研究編
-
広島工業大学紀要. 研究編 39 103-112, 2005-02
広島工業大学
- Tweet
Keywords
Details 詳細情報について
-
- CRID
- 1050858707644945152
-
- NII Article ID
- 40006641291
- 120005403221
-
- NII Book ID
- AA11599110
-
- ISSN
- 13469975
-
- NDL BIB ID
- 7256527
-
- Text Lang
- ja
-
- Article Type
- departmental bulletin paper
-
- Data Source
-
- IRDB
- NDL Search
- CiNii Articles
- KAKEN