- 【Updated on May 12, 2025】 Integration of CiNii Dissertations and CiNii Books into CiNii Research
- Trial version of CiNii Research Knowledge Graph Search feature is available on CiNii Labs
- Suspension and deletion of data provided by Nikkei BP
- Regarding the recording of “Research Data” and “Evidence Data”
Demonstration of New Microelectrode Design to Enhance Sensitivity of Dielectrophoretic Impedance Measurement
-
- Nakano, Michihiko
- Faculty of Information Science and Electrical Engineering, Kyushu University
-
- Inaba, Masafumi
- Faculty of Information Science and Electrical Engineering, Kyushu University
-
- Murakami, Tomoko
- Sumitomo Pharma Company, Ltd.
-
- Sakurai, Maho
- Sumitomo Pharma Company, Ltd.
-
- Suehiro, Junya
- Faculty of Information Science and Electrical Engineering, Kyushu University
Description
Dielectrophoretic impedance measurement (DEPIM) is a method using a microelectrode for measuring a target suspended in a solution by combining dielectrophoretic (DEP) trapping of the target and simultaneous measurement of impedance varied with the trapping. DEPIM can be utilized to detect bacteria and viruses without any chemical additive since DEPIM efficiency depends on the DEP trapping dominated by the microelectrode shape. This letter aims to demonstrate a new microelectrode design to increase bacteria detection efficiency instead of the conventional interdigitated microelectrode. The microelectrode having a serpentine gap as a sinusoidal waveform profile was proposed. The new microelectrode was compared with the interdigitated one in numerical simulation and experiments. The numerical simulation demonstrates that the serpentine microelectrode traps all the targets in a laminar flow in a microchannel. In contrast, the interdigitated one placed parallel to the microchannel does not because the target flowing away from the edges of the microelectrode cannot be trapped. The experiments using three kinds of bacteria were carried out. It was demonstrated that the serpentine microelectrode represented a sensitivity 10^4 times higher than the interdigitated one when a small amount of the sample solution was tested for a short time (1 min).
Journal
-
- IEEE Sensors Letters
-
IEEE Sensors Letters 7 (8), 4501404-, 2023-07-20
Institute of Electrical and Electronics Engineers (IEEE)
- Tweet
Keywords
Details 詳細情報について
-
- CRID
- 1050867278041558272
-
- ISSN
- 24751472
-
- HANDLE
- 2324/7183330
-
- Text Lang
- en
-
- Article Type
- journal article
-
- Data Source
-
- IRDB