- 【Updated on May 12, 2025】 Integration of CiNii Dissertations and CiNii Books into CiNii Research
- Trial version of CiNii Research Knowledge Graph Search feature is available on CiNii Labs
- 【Updated on June 30, 2025】Suspension and deletion of data provided by Nikkei BP
- Regarding the recording of “Research Data” and “Evidence Data”
Aortic Valve Predilatation with a Small Balloon, without Rapid Pacing, prior to Transfemoral Transcatheter Aortic Valve Replacement
-
- Anupama Shivaraju
- Deutsches Herzzentrum München, Department for Cardiovascular Diseases, Technische Universität München, Lazarettstr. 36, 80636 Munich, Germany
-
- Christian Thilo
- Department of Cardiology, Klinikum Augsburg, Herzzentrum Augsburg-Schwaben, Stenglinstr. 2, 86156 Augsburg, Germany
-
- Neal Sawlani
- Department of Cardiology, Advocate Christ Medical Center, 4440 W. 95th Street, Oak Lawn, IL, USA
-
- Ilka Ott
- Deutsches Herzzentrum München, Department for Cardiovascular Diseases, Technische Universität München, Lazarettstr. 36, 80636 Munich, Germany
-
- Heribert Schunkert
- Deutsches Herzzentrum München, Department for Cardiovascular Diseases, Technische Universität München, Lazarettstr. 36, 80636 Munich, Germany
-
- Wolfgang von Scheidt
- Department of Cardiology, Klinikum Augsburg, Herzzentrum Augsburg-Schwaben, Stenglinstr. 2, 86156 Augsburg, Germany
-
- Adnan Kastrati
- Deutsches Herzzentrum München, Department for Cardiovascular Diseases, Technische Universität München, Lazarettstr. 36, 80636 Munich, Germany
-
- Albert Markus Kasel
- Deutsches Herzzentrum München, Department for Cardiovascular Diseases, Technische Universität München, Lazarettstr. 36, 80636 Munich, Germany
Search this article
Description
<jats:p><jats:italic>Objectives.</jats:italic> The aim of this study is to assess the feasibility and clinical outcome of transcatheter aortic valve replacement (TAVR) using aortic valve predilatation (AVPD) with a small, nonocclusive balloon.<jats:italic> Background.</jats:italic> Balloon aortic valvuloplasty (BAV) under rapid pacing is generally performed in TAVR to ensure the passage and sufficient deployment of the prosthesis in the stenotic AV. BAV may cause serious complications, such as left ventricular stunning or cerebrovascular embolism.<jats:italic> Methods.</jats:italic> A cohort of 50 consecutive patients with severe aortic stenosis underwent transfemoral TAVR with the Edwards Sapien 3-heart valve. All patients underwent AVPD with a small, nonocclusive balloon (12 × 60 or 14 × 60 mm) without rapid pacing. Procedural data and clinical outcomes were analyzed.<jats:italic> Results.</jats:italic> The mean age of the cohort was <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="M1"><mml:mn fontstyle="italic">81</mml:mn><mml:mo>±</mml:mo><mml:mn fontstyle="italic">6</mml:mn></mml:math> years and the mean logistic EuroSCORE (European System for Cardiac Operative Risk Evaluation) was <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="M2"><mml:mn fontstyle="italic">13</mml:mn><mml:mo>±</mml:mo><mml:mn fontstyle="italic">9</mml:mn></mml:math>. Crossing the AV and prosthesis implantation was successful in all cases. The postprocedural mean AV gradient was <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="M3"><mml:mn fontstyle="italic">12</mml:mn><mml:mo>±</mml:mo><mml:mn fontstyle="italic">5</mml:mn></mml:math> mmHg. There were no cases of aortic regurgitation ≥ grade 2. No periprocedural stroke occurred. One patient (2%) with chronic atrial fibrillation displayed a transient Wernicke aphasia occurring more than 24 hours after TAVR. Mortality was 0% at 30 days after procedure.<jats:italic> Conclusion.</jats:italic> In TAVR, AVPD with a small, nonocclusive balloon can be safely performed. By avoiding rapid pacing, this technique may be a valid alternative to traditional BAV. Whether or not the use of APVD without rapid pacing translates into less periprocedural complications needs to be assessed in future studies.</jats:p>
Journal
-
- BioMed Research International
-
BioMed Research International 2018 1-6, 2018
Wiley
- Tweet
Details 詳細情報について
-
- CRID
- 1360016866574707712
-
- ISSN
- 23146141
- 23146133
-
- Data Source
-
- Crossref