Comparison of Ocular Wavefront Aberration Measurements Obtained Using Two Hartmann–Shack Wavefront Aberrometers

DOI Web Site 参考文献37件 オープンアクセス

抄録

<jats:sec> <jats:title>Objectives:</jats:title> <jats:p>To assess agreement between measurements of ocular wavefront aberrations obtained using the Pentacam AXL Wave (Oculus Optikgeräte GmbH) (Aberrometer A) and KR-1W (Topcon Corp) (Aberrometer B), both of which are based on the Hartmann–Shack principle.</jats:p> </jats:sec> <jats:sec> <jats:title>Methods:</jats:title> <jats:p>In this prospective case–control study, ocular wavefront aberrations measurements were obtained using both aberrometers in patients with keratoconus (KC) and control participants. Ocular wavefront aberrations were measured through the natural pupil without dilation using both devices in a dark room. For both aberrometers, accommodation was inhibited by automatically adding fogging. The individual Zernike coefficients from the second to fourth order were compared between the two aberrometers for a 4-mm pupil diameter.</jats:p> </jats:sec> <jats:sec> <jats:title>Results:</jats:title> <jats:p>Twenty-six KC and 29 control eyes were assessed. Statistically significant correlations (<jats:italic toggle="yes">P</jats:italic><0.05) were observed for all Zernike coefficients, except for Z<jats:sub>4</jats:sub> <jats:sup>−2</jats:sup> in the control group. Bland–Altman analysis indicated good agreement between aberrometers and no statistically significant differences in the control group. However, in the KC group, patterns of proportional error were observed in vertical coma Z<jats:sub>3</jats:sub> <jats:sup>−1</jats:sup> (r=0.338, <jats:italic toggle="yes">P</jats:italic>=0.008), trefoil Z<jats:sub>4</jats:sub> <jats:sup>−4</jats:sup> (r=0.701, <jats:italic toggle="yes">P</jats:italic>=0.003), secondary astigmatism Z<jats:sub>4</jats:sub> <jats:sup>−2</jats:sup> (r=0.348, <jats:italic toggle="yes">P</jats:italic>=0.025), and spherical aberrations Z<jats:sub>4</jats:sub> <jats:sup>0</jats:sup> (r=0.407, <jats:italic toggle="yes">P</jats:italic>=0.012).</jats:p> </jats:sec> <jats:sec> <jats:title>Conclusions:</jats:title> <jats:p>The Zernike coefficient values measured by the two aberrometers were well correlated in the control and KC groups. However, in eyes with KC, Aberrometer B tended to present greater values in several Zernike coefficients than Aberrometer A, suggesting that wavefront measurements obtained using the two aberrometers are not interchangeable in patients with KC.</jats:p> </jats:sec>

収録刊行物

参考文献 (37)*注記

もっと見る

関連プロジェクト

もっと見る

キーワード

詳細情報 詳細情報について

問題の指摘

ページトップへ