Investigate the Equivalence of Neutrons and Protons in Single Event Effects Testing: A Geant4 Study

抄録

<jats:p>Neutron radiation on advanced integrated circuits (ICs) is becoming important for their reliable operation. However, a neutron test on ICs is expensive and time-consuming. In this work, we employ Monte Carlo simulation to examine if a proton test can replace or even accelerate the neutron test, and we found that 200 MeV protons are the closest to resembling neutron radiation with five main differences. This 200 MeV concur with the suggestion from National Aeronautics and Space Administration (NASA, Washington, DC, USA). However, the impacts of the five differences on single event effects (SEEs) require future work for examination.</jats:p>